Search results for "vision."

showing 10 items of 4900 documents

Effect of Color on Contrast Sensitivity with Two Different Accommodative Stimuli

1993

We studied the influence of color and accommodation on the contrast sensitivity function (CSF). At the same time, we measured the effect of axial chromatic aberration (ACA) on the CSF. The CSF's of two observers were determined using red, green, blue, and white light, at 5- and 0.5-m viewing distances. At 5 m the CSF's were measured with natural vision and also with lenses which compensated the ACA. Results show that the effect of ACA on the CSF is to reduce the sensitivity to blue with respect to the red. The difference in sensitivity between these two colors is between 50 and 150% and varies with the frequency and the subject. When the ACA is compensated the influence of the color on the …

AdultPhysicsmedicine.medical_specialtyLightgenetic structuresbusiness.industryColour VisionAccommodation OcularStimulus (physiology)eye diseasesContrast SensitivityOphthalmologyNear visionOpticsSpectral sensitivityChromatic adaptationOphthalmologyChromatic aberrationmedicineWhite lightHumansSensitivity (control systems)businessColor PerceptionOptometryOptometry and Vision Science
researchProduct

Visual Acuity in Simple Myopic Astigmatism: Influence of Cylinder Axis

2006

Purpose. The relationship between astigmatic refractive errors and their associated visual acuity has been studied in recent years in the context of refractive power space. The influence of the axis of astigmatism remains a matter of controversy. Our goal in this study is to provide additional experimental evidence to clarify this subject. The influence of the simulated axis orientation was compared with other factors that affect visual acuity such as the particular design of the test and the differences between eyes. Methods. Simple myopic astigmatism from 0 to 3.00 D, in steps of 0.25 D, and with five different axes between 0° and 90°, were simulated on four healthy eyes of young observer…

AdultRefractive errorVisual acuitygenetic structuresOrientation (computer vision)Visual AcuityAstigmatismContext (language use)Optical powerAstigmatismPrognosisRefraction Ocularmedicine.diseaseSubjective refractioneye diseasesVision disorderOphthalmologyMyopiamedicineHumansOptometrymedicine.symptomOptometryMathematicsOptometry and Vision Science
researchProduct

Impact of the line of sight on toric phakic intraocular lenses for hyperopia

2003

We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.

AdultReoperationRefractive errormedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVision DisordersVisual AcuityComa (optics)Intraocular lensUncorrected visual acuityPhakic intraocular lensPupilVision disorderForeign-Body MigrationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansbusiness.industryAstigmatismCorneal TopographyPupilmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleSurgeryAsthenopiasense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Blue-yellow deficiencies in young moderate smokers.

2021

Purpose To evaluate whether tobacco affects color vision in young moderate smokers. Methods Chromatic mechanisms of 13 moderate smokers (10–20 cigarettes/day and at least 5 years smoking) and 17 non-smokers in the 18–35 age range were assessed with the Farnsworth-Munsell 100-hue (FM100h) test and short wavelength automated perimetry (SWAP). Results FM100h Total Error Scores (TES) were higher for smokers, and although differences were not significant (p = 0.14), a linear model with principal component analysis was able to explain 95% of the variance in TES and red-green partial error scores, though not in blue-yellow partial error scores (p = 0.07), using the number of years as smokers and t…

AdultRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresAdolescentColor visionPilot ProjectsAudiologySensitivity lossRetinal ganglionTotal errorYoung smokers03 medical and health sciencesYoung Adult0302 clinical medicineShort wavelength automated perimetryMedicineHumansDifference mapSmokersColour visionbusiness.industryColour VisionBlue/yellow perimetry030221 ophthalmology & optometryLinear ModelsVisual Field TestsBlue-yellow perimetryOriginal Articlebusiness030217 neurology & neurosurgeryColor PerceptionOptometryJournal of optometry
researchProduct

Bimodal sensory stimulation-induced seizures.

1987

Abstract A curious case is reported in which the patient, a young woman, exibited convulsive seizures when approaching closely to a television. The visual and acoustic stimulation did not change her EEG, whereas simultaneous stimulation with both the modalities induced bilateral and symmetrical high-voltage spikes (with their diffusion) that led to a convulsive seizure. Results are discussed with relation to the literature.

AdultSensory stimulation therapymedicine.diagnostic_testStimulationElectroencephalographyGeneral MedicineElectroencephalographyConvulsive seizureSimultaneous stimulationConvulsive SeizuresNeurologyAcoustic StimulationSeizuresmedicineHumansFemaleTelevisionsense organsNeurology (clinical)PsychologyNeurosciencePhotic StimulationActa neurologica Scandinavica
researchProduct

Influence of nifedipine on the metabolism of gingival fibroblasts.

1994

Calcium antagonists are the gold standard in the therapy of coronary heart disease and hypertension. The prototype of these drugs is nifedipine which, as well as its therapeutic effects on the cells of the cardiovascular system, also has unpleasant side effects on other organ systems. One side effect can be a missive hyperplasia of the gingiva, the reason for which are unclear. In vitro experiments were designed to elucidate the influence of nifedipine on the growth of human gingival fibroblasts in short and long term (72 hours, 6 weeks) cell culture. The following cellular parameters were determined quantitatively: cell proliferation (cell count, [3H]thymidine incorporation), protein synth…

AdultSide effectNifedipineCell SurvivalCellGingivaPharmacologyBiochemistrychemistry.chemical_compoundNifedipineCyclosporin aLactate dehydrogenasemedicineHumansCells CulturedDose-Response Relationship DrugChemistryCell growthDNAHyperplasiaFibroblastsmedicine.diseaseChromatography Ion Exchangemedicine.anatomical_structureCell cultureProtein BiosynthesisProteoglycansCell Divisionmedicine.drugBiological chemistry Hoppe-Seyler
researchProduct

Phase information of time-frequency transforms as a key feature for classification of atrial fibrillation episodes

2015

[EN] Patients suffering from atrial fibrillation can be classified into different subtypes, according to the temporal pattern of the arrhythmia and its recurrence. Nowadays, clinicians cannot differentiate a priori between the different subtypes, and patient classification is done afterwards, when its clinical course is available. In this paper we present a comparison of classification performances when differentiating paroxysmal and persistent atrial fibrillation episodes by means of support vector machines. We analyze short surface electrocardiogram recordings by extracting modulus and phase features from several time-frequency transforms: short-time Fourier transform, Wigner-Ville, Choi-…

AdultSupport Vector MachineEXPRESION GRAFICA EN LA INGENIERIAPhysiologyBiomedical EngineeringBiophysicsPhase (waves)Sensitivity and SpecificityS-transform general Fourier-family transformCohort StudiesTertiary Care CentersElectrocardiographysymbols.namesakeText miningPhysiology (medical)Atrial FibrillationmedicineHumanscardiovascular diseasesAgedAged 80 and overPrincipal Component AnalysisFourier Analysisbusiness.industryCardiovascular AgentsAtrial fibrillationPattern recognitionMiddle Agedmedicine.diseaseAtrial fibrillationTime–frequency analysisSupport vector machineFourier transformROC CurveFeature (computer vision)Fourier analysisArea Under CurveTime-frequency transformsHypertensionsymbolsArtificial intelligenceMedical emergencybusiness
researchProduct

Relation between fixation disparity and the asymmetry between convergent and divergent disparity step responses

2007

Abstract The neural network model of Patel et al. [Patel, S. S., Jiang, B. C., & Ogmen, H. (2001). Vergence dynamics predict fixation disparity. Neural Computation, 13 (7), 1495–1525] predicts that fixation disparity, the vergence error for a stationary fusion stimulus, is the result of asymmetrical dynamic properties of disparity vergence mechanisms: faster (slower) convergent than divergent responses give rise to an eso (exo) fixation disparity, i.e., over-convergence (under-convergence) in stationary fixation. This hypothesis was tested in the present study with an inter-individual approach: in 16 subjects we estimated the vergence step response to a 1 deg disparity stimulus with a subje…

AdultVision Disparitymedia_common.quotation_subjectModels NeurologicalFixation OcularStimulus (physiology)AsymmetryDivergencelaw.inventionModels of neural computationOpticslawHumansmedia_commonMathematicsVision Binocularbusiness.industryMathematical analysisConvergence OcularNoniusSensory SystemsOphthalmologyConvergent and divergent productionNonius linesBinocular visionConvergenceFixation disparitybusinessBinocular visionPhotic StimulationVision Research
researchProduct

Temporal Structure of Human Gaze Dynamics Is Invariant During Free Viewing.

2015

We investigate the dynamic structure of human gaze and present an experimental study of the frequency components of the change in gaze position over time during free viewing of computer-generated fractal images. We show that changes in gaze position are scale-invariant in time with statistical properties that are characteristic of a random walk process. We quantify and track changes in the temporal structure using a well-defined scaling parameter called the Hurst exponent, H. We find H is robust regardless of the spatial complexity generated by the fractal images. In addition, we find the Hurst exponent is invariant across all participants, including those with distinct changes to higher or…

AdultVisual acuityAdolescentEye MovementsComputer scienceInformationSystems_INFORMATIONINTERFACESANDPRESENTATION(e.g.HCI)ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONVisual Acuitylcsh:MedicineNeural degenerationTemporal lobeOcular Motility DisordersYoung AdultFractalInformationSystems_MODELSANDPRINCIPLESOcular Motility DisordersMuscle Stretching ExercisesmedicineHumansComputer visionInvariant (mathematics)lcsh:ScienceHurst exponentMultidisciplinarybusiness.industrylcsh:REye movementComputational BiologyRandom walkGazeTemporal LobeFractalsHuman visual system modelNerve Degenerationlcsh:QArtificial intelligencemedicine.symptombusinessResearch ArticlePLoS ONE
researchProduct

Monocular versus binocular pupillometry.

2004

Purpose To quantify differences between monocular and binocular pupil size measurement under scotopic and mesopic conditions. Setting Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. Methods Computerized dynamic pupillometry (P2000 SA, Procyon Instruments Ltd.) was used at 3 illumination levels: scotopic at 0.03 lux, mesopic low at 0.82 lux, and mesopic high at 6.4 lux. One hundred forty eyes of 70 healthy volunteers without ocular pathology were examined. The subjects were divided into 2 groups. In the first group, the pupil diameter was measured binocularly first. In the secon…

Adultgenetic structuresAdolescentMesopic visionmedicine.medical_treatmentDark AdaptationDiagnostic Techniques OphthalmologicalVision MonocularStatistical significanceRefractive surgeryMedicineHumansScotopic visionVision BinocularMonocularbusiness.industryPupileye diseasesSensory SystemsOphthalmologyQuartileOptometrySurgerysense organsbusinessBinocular visionPupillometryJournal of cataract and refractive surgery
researchProduct