Search results for "visual acuity"

showing 10 items of 456 documents

Retinal myelinated nerve fibers associated with macular pseudohole

2008

We report the case of a 24-year-old woman who presented unilateral extensive peripapillary myelinated nerve fibers associated with macular pseudohole and bilateral low myopia. Visual acuity, slit lamp biomicroscopy, automated perimetry, fundus color photography, and optical coherence tomography (Stratus® OCT) were performed. We discuss the clinical findings and diagnostic details of unilateral extensive peripapillary myelinated nerve fibers associated with macular pseudohole.

AdultVisual acuitygenetic structuresMyelinated nerve fiberNerve fiberEpiretinal membrane Macular pseudohole Oligodendrocytes Retinal myelinated nerve fibersFundus (eye)Nerve Fibers MyelinatedRetinal DiseasesmedicineHumansMacula LuteaFluorescein AngiographyMacular holebusiness.industrySettore MED/30 - Malattie Apparato VisivoOptic NerveAnatomymedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structureOptic nerveMaculopathyFemalesense organsEpiretinal membranemedicine.symptombusiness
researchProduct

Changes in colour discrimination during the menstrual cycle.

2006

A group of normal women of reproductive age were recruited to investigate colour discrimination during the various phases of the menstrual cycle. Colour vision was tested with the Farnsworth-Munsell 100-hue arrangement test, and the test was administered at 3 time points: the beginning of the cycle, ovulation, and the end of the cycle. We found that colour discrimination was better at ovulation than at the other 2 time points. It is possible that psychological as well as hormonal factors could contribute to improved colour vision performance at ovulation.

Adultgenetic structuresColor visionmedia_common.quotation_subjectVisual AcuityPhysiologyReproductive ageSettore BIO/10 - BiochimicamedicineHumansColor perception testOvulationMenstrual cycleMenstrual Cyclemedia_commonColor Perception Testsmedicine.diagnostic_testSettore MED/30 - Malattie Apparato Visivobusiness.industryColour VisionGeneral Medicineeye diseasesSensory SystemsMestrual CycleOphthalmologybusinessFarnsworth-Munsell 100 hue testColor PerceptionOphthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde
researchProduct

Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.

2011

Purpose To examine differences in efficacy, accuracy, safety, and changes in aberrations between femtosecond and mechanical microkeratome laser in situ keratomileusis (LASIK) for myopia. Setting Department of Ophthalmology, Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China. Design Evidence-based manuscript. Methods Data sources, including PubMed, Medline, EMBASE, and Cochrane Controlled Trials Register, were searched to identify potentially relevant prospective randomized controlled trials. Primary outcome measures were efficacy (uncorrected distance visual acuity ≥20/20), accuracy (±0.50 diopter mean spherical equivalent), and safety (loss of ≥2 l…

Adultmedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresDatabases Factualmedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSensitivity and Specificitylaw.inventionYoung AdultPostoperative ComplicationsRandomized controlled triallawMicrokeratomemedicineMyopiaHumansRegistriesDioptreRandomized Controlled Trials as TopicEquipment Safetybusiness.industryLASIKReproducibility of ResultsOdds ratioMiddle Agedeye diseasesSensory SystemsConfidence intervalSurgeryOphthalmologyTreatment OutcomeMeta-analysisSurgeryLasers ExcimerbusinessJournal of cataract and refractive surgery
researchProduct

Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser

2011

PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…

Adultmedicine.medical_specialtyCorneal endotheliumgenetic structuresEndotheliummedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCell CountKeratomileusisRefraction OcularYoung AdultOphthalmologyMyopiamedicineHumansProspective StudiesDioptrebusiness.industryEndothelium CornealLASIKCorneal Endothelial Cell LossContact Lenses Hydrophiliceye diseasesSurgeryContact lensOphthalmologymedicine.anatomical_structureLens (anatomy)FemtosecondLasers ExcimerSurgerysense organsbusinessJournal of Refractive Surgery
researchProduct

Visual performance with simultaneous vision multifocal contact lenses.

2011

Purpose:  The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods:  In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…

Adultmedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivityOpticsOphthalmologymedicineContrast (vision)Humansmedia_commonMathematicsMonocularCross-Over Studiesbusiness.industryGlare (vision)Accommodation OcularPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesContact lensOphthalmologyTreatment OutcomebusinessOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.

2013

Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …

Adultmedicine.medical_specialtyIntraocular pressurePhakic Intraocular Lensesgenetic structuresVisual AcuitySpherical equivalentBiocompatible MaterialsCell CountRefraction OcularSafety indexCorneaYoung AdultLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreImplantable collamer lensEfficacy indexbusiness.industryEndothelium CornealMiddle Agedeye diseasesSensory SystemsPosterior chamber phakic intraocular lensEndothelial cell densityOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsCollagenbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Femtosecond laser versus mechanical keratome LASIK for myopia.

2005

To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…

Adultmedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisSurgical FlapsContrast SensitivityCorneaTonometry OcularMicrokeratomemedicineMyopiaHumansProspective StudiesDioptremedicine.diagnostic_testbusiness.industryLasersLASIKCorneal Topographymedicine.diseaseCorneal topographyeye diseasesPhotorefractive keratectomySurgeryOphthalmologyTreatment Outcomesense organsmedicine.symptombusinessOphthalmology
researchProduct

Learning Curve and Fatigue Effect of Flicker Defined Form Perimetry

2011

To evaluate the learning curve and fatigue effect of flicker defined form (FDF) perimetry.Prospective cross-sectional study.One hundred forty-one eyes of 75 healthy subjects were included in the study. Every subject was measured 3 times on 3 different days within 3 months. Differences among the tests were analyzed for mean sensitivity (MS), mean deviation (MD), pattern standard deviation (PSD), reliability indices, test duration, and test points5% and0.5% in 75 right eyes on the basis of linear mixed models for repeated measurements. To assess the effect of fatigue, differences of MS, MD, and PSD values between 66 left and right eyes were evaluated regarding alterations between these 3 exam…

Adultmedicine.medical_specialtyVisual AcuitySignificant learningSensitivity and SpecificityPattern standard deviationOphthalmologymedicineHumansProspective StudiesIntraocular PressureAgedbusiness.industryFlickerHealthy subjectsGlaucomaMiddle AgedTest durationAbsolute deviationOphthalmologyCross-Sectional StudiesVisual Field TestsAsthenopiaVisual FieldsbusinessLearning CurveAmerican Journal of Ophthalmology
researchProduct

Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.

2005

To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…

Adultmedicine.medical_specialtyVisual acuityBiometrymedicine.medical_treatmentLens Capsule CrystallineCapsular tension ringIntraocular lensCataract ExtractionGroup differencesLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationEquipment DesignProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyCapsular bagMicroscopy Electron ScanningSurgerymedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

The effect of simulated normal and amblyopic higher-order aberrations on visual performance.

2012

Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …

Adultmedicine.medical_specialtyVisual acuityCorneal Wavefront Aberrationgenetic structuresmedia_common.quotation_subjectVisual AcuityAmblyopiaPupilContrast SensitivityYoung AdultOphthalmologyOptical transfer functionmedicineContrast (vision)Humansmedia_commonContrast levelbusiness.industryAberrometryPupil sizeAstigmatismPupilModels TheoreticalRefractive Errorseye diseasesOphthalmologyAberrations of the eyePediatrics Perinatology and Child HealthOptometrysense organsSpatial frequencymedicine.symptombusinessJournal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus
researchProduct