Search results for "visual"

showing 10 items of 7386 documents

Excimer laser photorefractive keratectomy for high myopia

1995

Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentEye diseaseVisual AcuityRefraction OcularExcimerPhotorefractive KeratectomyEpitheliumCorneaVision disorderCorneal OpacityOphthalmologyMyopiamedicineHumansIntraocular PressureDioptreExcimer laserbusiness.industryMiddle AgedPrognosismedicine.diseaseAblationeye diseasesSensory SystemsPhotorefractive keratectomyOphthalmologyFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Long-term Results After Transconjunctival Resuturing of the Scleral Flap in Hypotony Following Trabeculectomy

2013

Purpose To present the 4-year follow-up results in the surgical treatment of hypotony following trabeculectomy with mitomycin C in glaucoma patients with additional flap sutures. Design Retrospective interventional case series. Methods Since 2006, 53 patients with hypotony maculopathy attributable to overfiltration following glaucoma surgery (trabeculectomy with mitomycin C) were included in this institutional study. We were able to follow up intraocular pressure (IOP) and distance-corrected visual acuity in 33 (62%) over 4 years, whereas all were followed over 2 years. To elevate IOP, we placed tangential transconjunctival sutures through the scleral flap and connected them to the adjacent…

AdultMaleReoperationIntraocular pressuremedicine.medical_specialtyTime FactorsVisual acuitygenetic structuresmedicine.medical_treatmentGlaucomaOcular HypotensionTrabeculectomySurgical FlapsTonometry OcularOphthalmologyGlaucoma surgeryHumansMedicineTrabeculectomyIntraocular PressureAgedRetrospective StudiesScleral flapAged 80 and overbusiness.industrySuture TechniquesMitomycin CGlaucomaMiddle Agedmedicine.diseaseeye diseasesScleraSurgeryOphthalmologyTreatment Outcomemedicine.anatomical_structureFemalesense organsmedicine.symptombusinessConjunctivaScleraFollow-Up StudiesAmerican Journal of Ophthalmology
researchProduct

Clinical analysis following lumbar interspinous devices implant: where we are and where we go

2014

Objectives:We present our experience with patients treated with interspinous devices who are affected by neurogenic intermittent claudication (NIC) or lumbar disc herniation (LDH) where the interspinous system has been inserted following microdiscectomy.Study design:Retrospective study.Methods:This study included patients (n=100) with NIC secondary to lumbar spinal stenosis (group 1), and patients (n=100) with LDH (group 2) in whom the interspinous device has been implanted following radicular decompression in a period spanning 6 years. The latter have been compared with a homogenous group of patients (n=100) where no interspinous system has been implanted following microdiscectomy (group 3…

AdultMaleReoperationMicrosurgerymedicine.medical_specialtyTime FactorsVisual analogue scaleDecompressionlumbar interspinous devicesAdult Prostheses and Implants Aged Decompression Surgical Disability Evaluation Female Follow-Up Studies Intermittent Claudication Intervertebral Disc Displacement Humans Lumbar Vertebrae Microsurgery Minimally Invasive Surgical Procedures Middle Aged Male Retrospective Studies Pain Measurement Patient Satisfaction Surveys and Questionnaires Reoperation Recurrence Treatment Outcome Spinal StenosisDisability EvaluationSpinal StenosisLumbarRecurrenceSurveys and QuestionnairesmedicineHumansMinimally Invasive Surgical ProceduresAgedPain MeasurementRetrospective StudiesLumbar VertebraeSettore MED/27 - Neurochirurgiabusiness.industryLumbar spinal stenosisProstheses and ImplantsGeneral MedicineIntermittent ClaudicationMiddle AgedDecompression Surgicalmedicine.diseaseIntermittent claudicationOswestry Disability IndexSurgeryTreatment OutcomeNeurologyPatient SatisfactionFemaleNeurology (clinical)Implantmedicine.symptombusinessClaudicationIntervertebral Disc DisplacementFollow-Up StudiesSpinal Cord
researchProduct

Characterization of the effect of intracorneal ring segment in corneal ectasia after laser refractive surgery

2018

Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes …

AdultMaleReoperationmedicine.medical_specialtyCorneal ectasiagenetic structuresCorneal Surgery Lasermedicine.medical_treatmentVisual AcuityAstigmatismProsthesis DesignRefraction OcularCorneal Diseaseslaw.inventionCorneaCorneal ectasiaPostoperative ComplicationsLens Implantation IntraocularlawIntracorneal ring segmentEctasiaOphthalmologyRefractive surgerymedicineHumansPost-LASIK ectasiaPentacam hrIntracorneal ring segmentRetrospective StudiesÓpticaPost-LASIK ectasiabusiness.industryCorneal TopographyGeneral MedicineMiddle Agedmedicine.diseaseLasereye diseasesOphthalmologyFemalesense organsbusinessDilatation PathologicFollow-Up StudiesEuropean Journal of Ophthalmology
researchProduct

Results of an Adaptive Surgical Approach for Managing Late Onset Hypotony After Trabeculectomy With Mitomycin C.

2018

OBJECTIVES The objective of this study is to investigate the results of an adaptive approach of bleb revision surgery for late onset hypotony after trabeculectomy with mitomycin C because of bleb leakage and/or scleral melting. METHODS A total of 29 eyes of 27 patients, aged 63.8±11.7 years with hypotony maculopathy [intraocular pressure (IOP), ≤6 mm Hg] because of late onset bleb leakage and/or scleral melting after trabeculectomy with mitomycin C in which minimally invasive transconjunctival suturing of the scleral flap was impossible were enrolled in this retrospective interventional case series. External bleb leakage was seen in 16 eyes, 11 eyes suffered from scleral melting. Because of…

AdultMaleReoperationmedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentMitomycinVisual AcuityGlaucomaOcular HypotensionTrabeculectomy03 medical and health sciencesTonometry Ocular0302 clinical medicineBlisterPostoperative ComplicationsOphthalmologyGlaucoma surgeryMedicineTrabeculectomyHumansIntraocular PressureAgedRetrospective StudiesAged 80 and overbusiness.industryMitomycin CGlaucomaMiddle Agedmedicine.diseaseCombined Modality Therapyeye diseasesScleraScleral DiseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsBleb (medicine)medicine.symptombusiness030217 neurology & neurosurgeryScleraJournal of glaucoma
researchProduct

Endothelial study of iris-claw phakic lens: four year follow-up.

1998

Abstract Purpose: To study quantitative and morphometric endothelial changes in phakic eyes implanted with the Worst iris-claw lens to correct high myopia. Setting: Department of Ophthalmology, University Hospital “La Fe”, Valencia, Spain. Material and Methods: This retrospective study involved 111 phakic eyes (73 patients) implanted with the Worst iris-claw lens. Noncontact specular microscopy and computer-assisted analysis was performed preoperatively and 6 months and 1, 2, 3, and 4 years postoperatively. Results: The mean cell loss was 3.85% at 6 months, 6.59% at 1 year, 9.22% at 2 years, 11.68% at 3 years, and 13.42% at 4 years. At 2 years, the hexagonality and coefficient variation in …

AdultMaleReoperationmedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresAnterior Chambermedicine.medical_treatmentEye diseaseCorneal TouchVisual AcuityIrisIntraocular lensCell CountPhakic intraocular lensCorneal DiseasesVision disorderPostoperative ComplicationsLens Implantation IntraocularOphthalmologyCorneaMyopiaMedicineHumansCell SizeRetrospective Studiesbusiness.industryEndothelium CornealMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologymedicine.anatomical_structureSurgeryFemalesense organsmedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Refractive lens exchange with the Acri. Twin asymmetric diffractive bifocal intraocular lens system

2009

PURPOSE To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses. METHODS The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at …

AdultMaleReoperationmedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIn patientProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryPresbyopiaGeneral MedicinePresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyHyperopiaIntraocular lenses030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients.

2012

Purpose Flicker defined form perimetry (FDF) and frequency doubling technology perimetry (FDT) are alleged to detect glaucoma at an earlier stage than standard automated perimetry (SAP). It is the purpose of this study to investigate the structure-function relationship between FDF, FDT, SAP, and confocal scanning laser ophthalmoscopy (cSLO) in patients with glaucoma. Methods Seventy-six patients with glaucoma were included in the study. Patients were tested with SAP, Matrix-FDT, FDF perimetry, and cSLO. Structure-function relationships between global and sectoral cSLO parameters and global and sectoral mean sensitivity (MS) of SAP, Matrix-FDT, and FDF were calculated using Spearman's rank c…

AdultMaleRetinal Ganglion CellsIntraocular pressuremedicine.medical_specialtygenetic structuresGlaucomaOphthalmologyLinear regressionmedicineHumansIn patientTomographyIntraocular PressureMathematicsRank correlationRetrospective StudiesAutomated perimetryStructure functionReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesScanning laser ophthalmoscopyOphthalmoscopyVisual Field TestsFemaleVisual FieldsInvestigative ophthalmologyvisual science
researchProduct

Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields

2014

To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-…

AdultMaleRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresOptic DiskVision DisordersVisual AcuityNerve fiber layerGlaucomalaw.inventionTonometry OcularCellular and Molecular Neurosciencechemistry.chemical_compoundNerve FiberslawOphthalmologymedicineHumansProspective StudiesIntraocular PressureHeidelberg retina tomographOptic Nerve Headsbusiness.industryGlaucomaRetinalMiddle Agedmedicine.diseaseeye diseasesSensory SystemsVisual fieldConfocal scanning laser ophthalmoscopyOphthalmologyEarly Diagnosismedicine.anatomical_structurechemistryAchromatic lensVisual Field TestsFemaleOcular Hypertensionsense organsVisual FieldsbusinessCurrent Eye Research
researchProduct

Differentiating the differential rotation effect.

2011

As an observer views a picture from different viewing angles, objects in the picture appear to maintain their orientation relative to the observer. For instance, the eyes of a portrait appear to follow the observer as he or she views the image from different angles. We have explored this rotation effect, often called the Mona Lisa effect. We report three experiments that used portrait photographs to test variations of the Mona Lisa effect. The first experiment introduced picture displacements relative to the observer in directions beyond the horizontal plane. The Mona Lisa effect remained robust for vertical and/or diagonal observer displacements. The experiment also included conditions in …

AdultMaleRotationGaze directionsIndividualityExperimental and Cognitive PsychologyGaze perceptionPortraitArts and Humanities (miscellaneous)Developmental and Educational PsychologyDifferential rotationHumansComputer visionCommunicationbusiness.industryGeneral MedicineObserver (special relativity)Horizontal planeGazeSpace PerceptionVisual PerceptionFemaleArtificial intelligencebusinessPsychologyMona lisaPersonalityActa psychologica
researchProduct