Search results for "vol"
showing 10 items of 19880 documents
Numerical Procedures and their Practical Application in PV Module Analyses. Part IV: Atmospheric Transparency Parameters - Application
2020
Abstract The presented article relates to aspects of PV module testing using natural sunlight in outdoor conditions. It is a continuation of the article Part III: parameters of atmospheric transparency - determining and correlations. This article discusses the practical application of the indexes: atmosphere purity - k Tm , diffused component content - k s/o , beam clear sky index - K b - in testing various modules in outdoor conditions. Their influence on the conversion of modules made from various absorbers and various technologies is demonstrated. Their practical application in module testing in outdoor conditions is described and it - has been demonstrated that the results of the analys…
Measurements on partial discharge in on‐site operating power transformer: a case study
2018
This study presents the case study of a substation in-service power transformer referred to the on-site partial discharge (PD) detection and evaluation methods. An original methodology for simultaneous application of three methods is proposed: electrical, acoustic and ultra-high frequency. Transformer is powered by the power grid and no external generator is required according to the proposed methodology. Furthermore, several possibilities of applying these concurrent measurements and benefits of such solution in terms of result interpretation, interference resistance and on-site measurement applicability are indicated. The proposed methodology allows for a fast, accurate and secure PD diag…
The filter and calibration wheel for the ATHENA wide field imager
2016
The planned filter and calibration wheel for the Wide Field Imager (WFI) instrument on Athena is presented. With four selectable positions it provides the necessary functions, in particular an UV/VIS blocking filter for the WFI detectors and a calibration source. Challenges for the filter wheel design are the large volume and mass of the subsystem, the implementation of a robust mechanism and the protection of the ultra-thin filter with an area of 160 mm square. This paper describes performed trade-offs based on simulation results and describes the baseline design in detail. Reliable solutions are envisaged for the conceptual design of the filter and calibration wheel. Four different varian…
A New Approach to Partial Discharge Detection Under DC Voltage: Application to Different Materials
2021
Usability of a new Direct Current Periodic waveform for partial discharge qualification in HVDC systems is exemplified by tests performed on different materials.
Partial discharges behavior under different rectified waveforms
2017
In this work, a previous software used to simulate partial discharges (PDs) under Alternating Current (AC) stress has been modified in order to evaluate the PDs behavior under a voltage stress close to the Direct Current (DC) waveform. By using a full-wave and a half-wave rectifier, the specimen with an air void defects has been subjected to a gradual constant stress. Finally, a capacitive filter has been inserted in order to produce a steadier voltage supply. Simulation results show that under an almost DC waveform, the PDs activity become less compared to AC stress.
Investigation and reduction of losses on inverter-fed induction motors
2017
An electric motor is more effective and flexible when supplied by a frequency converter. The frequency converter not only produces the fundamental voltage but also a set of higher harmonics which cause additional losses in the motor. Losses in the frequency converter are normally neglected in the drive dimensioning due to insufficient data available from manufacturers. Motor's losses can be reduced by increasing the switching frequency of frequency converters. An increase of the switching frequency may result in higher losses in the frequency converter. This work investigates analytically and experimentally the dependence of the losses of modern motor and frequency converter on a switching …
Novel multipactor studies in RF satellite payloads: Single-carrier digital modulated signals and ferrite materials
2017
In this work it is reviewed the most novel advances in the multipactor RF breakdown risk assessment devoted to RF satellite microwave passive devices employed in space telecommunication systems. On one side, it is studied the effect of transmitting a single-carrier digital modulated signal in the multipactor RF voltage threshold in a coaxial line. On the other hand, an analysis of the multipactor phenomenon in a parallel-plate waveguide containing a magnetized ferrite slab it is presented.
Photovoltaics: solar energy resources and the possibility of their use
2016
Abstract In this paper possibilities and limits of use of solar energy (like the best efficiencies of PV cells, world records and ‘notable exceptions’) were shown. Also some new ideas and concepts in photovoltaics (like new photovoltaic power plants or energy storage) were presented. Additionally authors try to predict development of solar power industry.
PD characteristics at Square Shaped Voltages Applying Two Different Detecting Techniques
2016
Nowadays power electronic converters are widely used and the fast switching voltage fronts results in an increased stress on the insulation material and may cause a reduction of the HV systems reliability. Nonsinusoidal voltage waveform have influence on the partial discharges (PD) characteristics in insulating systems due to the increased harmonic content which causes problems mainly in electrical PD measurement setups. In fact, impulse voltages cause strong switching disturbances, which make it much more difficult to distinguish PD signals from noise. This work investigates the influence of repetitive steep pulses on different types of test objects exposed to square wave voltages applying…
Partial discharges at different voltage waveshapes: Comparison between two different acquisition systems
2018
In modern HV apparatuses the wide use of electronic converters, increase the stress on the involved insulation systems and thus affect the reliability of the whole power grid. Additionally, such non-sinusoidal voltage shapes contain high gradient flanks that create problems in the detection of partial discharge (PD) activity. The aim of this paper is to discuss the methodology on how to suitably approach PD detection in insulation systems exposed to various voltage waveshapes in general by comparing two different measuring systems. The first one, equipped with a resonant PD decoupler, designed specifically for detection at typical power electronic waveshapes and the other one, based on an a…