Search results for "vox"
showing 10 items of 126 documents
Increased bioavailability of oral melatonin after fluvoxamine coadministration*1
2000
Background Fluvoxamine, a selective serotonin reuptake inhibitor, is known to elevate melatonin serum concentrations. It has not been clear whether these effects might be attributed to an increased melatonin production or to an decreased elimination of melatonin. The latter hypothesis was tested by this study. Methods Five healthy male volunteers (one CYP2D6 poor metabolizer) received 5 mg melatonin either with or without coadministration of 50 mg fluvoxamine. Serum concentrations of melatonin and fluvoxamine were assessed from 0 to 28 hours after melatonin intake. Results Coadministration of fluvoxamine, on average, led to an 17-fold higher (P <.05) area under concentration–time curve (AUC…
Multiscale three-dimensional imaging of intact human organs down to the cellular scale using hierarchical phase-contrast tomography
2021
ABSTRACTHuman organs are complex, three-dimensional and multiscale systems. Spatially mapping the human body down through its hierarchy, from entire organs to their individual functional units and specialised cells, is a major obstacle to fully understanding health and disease. To meet this challenge, we developed hierarchical phase-contrast tomography (HiP-CT), an X-ray phase propagation technique utilising the European Synchrotron Radiation Facility’s Extremely Brilliant Source: the world’s first high-energy 4th generation X-ray source. HiP-CT enabled three-dimensional and non-destructive imaging at near-micron resolution in soft tissues at one hundred thousand times the voxel size whilst…
CNN-based People Detection in Voxel Space using Intensity Measurements and Point Cluster Flattening
2021
In this paper real-time people detection is demonstrated in a relatively large indoor industrial robot cell as well as in an outdoor environment. Six depth sensors mounted at the ceiling are used to generate a merged point cloud of the cell. The merged point cloud is segmented into clusters and flattened into gray-scale 2D images in the xy and xz planes. These images are then used as input to a classifier based on convolutional neural networks (CNNs). The final output is the 3D position (x,y,z) and bounding box representing the human. The system is able to detect and track multiple humans in real-time, both indoors and outdoors. The positional accuracy of the proposed method has been verifi…
SU-E-T-509: DICOM Test Case Plans for Model-Based Dose Calculations Methods in Brachytherapy
2013
Purpose: The TG‐186 report provides guidance to early adopters of model‐based dose calculation algorithms (MBDCAs) for brachytherapy. A charge of the AAPM‐ESTRO Working Group on MBDCA is to develop well‐defined test case plans, available as references for the software commissioning process to be performed by end‐users. The aim of this work is to develop test case plans for a generic HDR 192 Ir source alone and in combination with a vaginal cylinder applicator with 180° tungsten‐alloy shielding in a DICOM‐based water phantom. Methods: A DICOM CT dataset was created with a 30 cm diameter water sphere surrounded by air. The voxel size was 1.33×1.33×1.33 mm3 for evaluating absorbed dose rate (c…
Brain structural alterations in Fabry disease: ROI-based and voxel-based analyses of diffusion tensor imaging parameters
2007
Influence of pixel size on quantification of airway wall thickness in computed tomography.
2009
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …
Reproducibility and accuracy in the morphometric and mechanical quantification of trabecular bone from 3Tesla magnetic resonance images
2014
Abstract Objective We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (μCT). Materials and methods We used magnetic resonance (MR) imaging and μCT to study the metaphyses of 5 sheep tibiae. The MR images (3 T) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180 μm. The μCT images were acquired using a scanner with a spatial resolution of 7.5 μm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of …
2016
Abstract. Various geoscientific applications require a fast prediction of fracture permeability for an optimal workflow. Hence, the objective of the current study is to introduce and validate a practical method to characterize and approximate single flow in fractures under different stress conditions by using a core-flooding apparatus, in situ X-ray computed tomography (CT) scans and a finite-volume method solving the Navier–Stokes–Brinkman equations. The permeability of the fractured sandstone sample was measured stepwise during a loading–unloading cycle (0.7 to 22.1 MPa and back) to validate the numerical results. Simultaneously, the pressurized core sample was imaged with a medical X-ray…
Differential Effects of Fluvoxamine and Other Antidepressants on the Biotransformation of Melatonin
2001
Melatonin, the predominant product of the pineal gland, is involved in the maintenance of diurnal rhythms. Nocturnal blood concentrations of melatonin have been shown to be enhanced by fluvoxamine, but not by other serotonin reuptake inhibitors. Because fluvoxamine is an inhibitor of several cytochrome P450 (CYP) enzymes, the authors studied the biotransformation of melatonin and the effects of fluvoxamine on the metabolism of melatonin in vitro using human liver microsomes and recombinant human CYP isoenzymes. Melatonin was found to be almost exclusively metabolized by CYP1A2 to 6-hydroxymelatonin and N-acetylserotonin with a minimal contribution of CYP2C19. Both reactions were potently in…
SMART TECHNIQUES FOR FAST MEDICAL IMAGE ANALYSIS AND PROCESSING
Medical Imaging has become an important transversal applications and re- search field that embraces a great variety of sciences. Imaging is the central science of measurement in diagnosis and treating diseases. The effort of the technological progress has made possible human imaging starting from a single molecule to the whole body. The open challenge is to treat the huge amount of medical informations with the use of smart and fast techniques that allows clinical and images data analysis and processing. In this ph.D. Thesis, many issues have been addressed and a certain amount of improvement in various fields have been produced, such as biom- etry, organs and tissues segmentation, MRI ther…