Search results for "wage"
showing 10 items of 731 documents
Mapping Sediment Accumulation Rate by using Volume magnetic Susceptibility Core Correlation in a contaminated Bay (Lake Geneva, Switzerland)
2003
The Bay of Vidy is the most contaminated area of Lake Geneva: contamination is caused by the effluent of the sewage treatment plant (STP) of the City of Lausanne. The implementation of a chemical stage in the treatment plant to remove phosphorus using FeC13 in 1971 is indirectly recorded in the lake sediments by a strong and sharp increase in the volume magnetic susceptibility (VMS) signal. A total of 43 sediment cores have been retrieved and measured for VMS. The synchronism of the VMS signal increase and its relation to the implementation of the P-removal stage in the STP has been shown in seven 137Cs-dated sediment cores. The VMS signal has been used to date by stratigraphie correlation …
Performance of a membrane-coupled high-rate algal pond for urban wastewater treatment at demonstration scale
2020
[EN] The objective of this study was to evaluate the performance of an outdoor membrane-coupled high-rate algal pond equipped with industrial-scale membranes for treating urban wastewater. Decoupling biomass retention time (BRT) and hydraulic retention time (HRT) by membrane filtration resulted in improved process efficiencies, with higher biomass productivities and nutrient removal rates when operating at low HRTs. At 6 days of BRT, biomass productivity increased from 30 to 66 and to 95 g.m(-3).d(-1) when operating at HRTs of 6, 4 and 2.5 days, respectively. The corresponding nitrogen removal rates were 4, 8 and 11 g N.m(-3).d(-1) and the phosphorous removal rates were 0.5, 1.3 and 1.6 g P…
The use of fish bile metabolite analyses as exposure biomarkers to pulp and paper mill effluents
1998
The exposure of caged one-year-old whitefish (Coregonus lavaretus) to wood extractives and chlorophenolics from pulp and paper mill effluents in Lake Saimaa (SE Finland) was investigated. Whitefish were exposed at 17 locations affected by effluents from pulp and paper mills and at 5 reference areas. Resin and fatty acids and chlorophenolics in bile were analysed by GC and GC-MS. Cholesterol concentration in bile was also measured. Results show that despite of process changes to ECF and waste water treatment improvements employed by the pulp and paper industry in the study area, it is still possible to detect elevated concentrations of these substances in the bile of fish exposed in the vici…
Effect of transition metals and homogeneous hydrogen producers in the hydrothermal liquefaction of sewage sludge
2022
Hydrothermal liquefaction (HTL) of sewage sludge (SS) was performed in the presence of metallic Zn, Fe and Ni to investigate their effect on the performances of the process in terms of product yields and quality. Experiments were performed in subcritical water at 350 ◦C for 10 min using each metal individually and in the presence of homogenous hydrogen producers like formic acid (FA) and KOH. Interesting results were obtained with Zn that when used alone or in the presence of KOH, increased the cumulative biocrude (BC) yields and resulted in energy recoveries (ER) higher than 100% with respect to initial energy content of the biomass, thus indicating that HTL of SS is globally endothermic. …
Ashes from Sewage Sludge and Bottom Sediments as a Source of Bioavailable Phosphorus
2018
Phosphorus is an element necessary for the growth of plants. As phosphate rock gets depleted, it becomes an increasingly scarce resource. Therefore, it seems necessary to implement simple methods of cheap and effective phosphorus recovery from waste. The ashes of municipal sewage sludge and bottom sediments constitute particularly valuable sources of phosphorus. However, these materials usually carry significant amounts of pollutants, including heavy metals. Optimization of ash phosphorus sequential extraction methods from a thermal conversion of sewage sludge and bottom sediments allows to select an effective and simple technology of phosphorus recovery, while maintaining low heavy metal p…
Use of biological and sedimentation models for designing Peñíscola WWTP.
2004
This paper presents Peñíscola wastewater treatment plant design. Peñíscola is a tourist city in Castellón (Spain), whose population changes significantly between summer and the rest of the year. The design of the biological and settling treatment units has been confirmed by computer model simulations and provided for biological organic matter, nitrogen and phosphorus removal. Two different treatment schemes have been proposed in order to optimize the plant performance during both seasonal operations. During low-load season, the plant will be operated under extended aeration conditions, so further sludge stabilization will not be needed. During high-load season, the plant will be operated un…
Vertical distribution of AhR-activating compounds in sediments contaminated by modernized pulp and paper industry
2013
Increased ethoxyresorufin-O-deethylase (EROD) activity is a sensitive biomarker of exposure to the chemicals which activate the aryl hydrocarbon receptor (AhR) and induce the cytochrome P450 system, such as many polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs). Pulp bleaching was one of the main sources of PCDDs and PCDFs until elemental chlorine free (ECF) and total chlorine free bleaching processes since 1990s have remarkably decreased but not completely eliminate discharges of these chemicals. In addition, historically contaminated sediments may act as a source of these persistent contaminants. In this study, the contam…
Low cost-sensors as a real alternative to on-line nitrogen analysers in continuous systems.
2009
This paper is focused on the evaluation of the applicability of low-cost sensors (pH and ORP) versus nutrient analysers for controlling biological nitrogen removal in WWTPs. A nutrient removal pilot plant located in Carraixet WWTP (Valencia, Spain) that is equipped with a significant number of nutrient analysers and low-cost sensors was used. The relations between reliable, cheap on-line sensors such as pH and ORP (located in anaerobic, anoxic and aerobic zones) and the nitrification/denitrification processes are provided. The nitrification process can be evaluated by measuring the pH difference between the first and last aerobic zones. The denitrification process can be evaluated by measur…
Effect of extended famine conditions on aerobic granular sludge stability in the treatment of brewery wastewater
2017
Results obtained from three aerobic granular sludge reactors treating brewery wastewater are presented. Reactors were operated for 60 d days in each of the two periods under different cycle duration: (Period I) short 6 h cycle, and (Period II) long 12 h cycle. Organic loading rates (OLR) varying from 0.7 kg COD m-3 d-1 to 4.1 kg COD m-3 d-1 were tested. During Period I, granules successfully developed in all reactors, however, results revealed that the feast and famine periods were not balanced and the granular structure deteriorated and became irregular. During Period II at decreased 12 h cycle time, granules were observed to develop again with superior structural stability compared to the…
Les étudiants anticipent-ils correctement la valeur de leur diplôme sur le marché du travail ?
2013
Documents de travail de l'IREDU, n°2013-1; Ce travail analyse la manière dont les étudiants de première année d'université anticipent leurs salaires futurs, puis compare ces salaires à ceux qu'ils peuvent réellement observer sur le marché du travail. Nos résultats montrent globalement une surestimation des salaires anticipés d'environ 9 pour cent en début de carrière, ce qui est cohérent avec des travaux réalisés dans d'autres pays. En revanche, les salaires anticipés après dix ans de carrières sont supérieurs de 28 pour cent aux salaires observés des diplômés à ancienneté comparable. Les résultats soulignent également l'importance de l'environnement familial lors du choix des études supéri…