Assessment of paradoxical anterior translation in a CR total knee prosthesis coupling dynamic RSA and FE techniques

2021

Purpose: The study aims were to assess the kinematic data, Internal-External (IE) rotation, and Antero-Posterior (AP) translation of the contact points between the femoral condyles and polyethylene insert and to develop a combined dynamic RSA-FE (Radiostereometric – Finite Element) model that gives results congruent with the literature. Methods: A cohort of 15 patients who underwent cemented cruciate-retaining highly congruent mobile-bearing total knee arthroplasty were analyzed during a sit-to-stand motor task. The kinematical data from Dynamic RSA were used as input for a patient-specific FE model to calculate condylar contact points between the femoral component and polyethylene insert. …

medicine.medical_specialtyKinematicsmedicine.medical_treatmentKinematicsRotationTranslation (geometry)ProsthesisCondyleTotal knee03 medical and health sciences0302 clinical medicineMobile bearingmedicineCoupling (piping)Orthopedics and Sports MedicineARTHROPLASTYMathematicsTKA FEATURESOrthodonticsOrthopedic surgery030222 orthopedicsOriginal PaperScience & TechnologyTKAGénéralités030229 sport sciencesDynamic RSAKinematicOrthopedicsOrthopedic surgerySurgeryFE analysiFE analysisLife Sciences & BiomedicineRD701-811
researchProduct

Analysis of different geometrical features to achieve close-to-bone stiffness material properties in medical device: A feasibility numerical study

2021

Background and objective: In orthopedic medical devices, elasto-plastic behavior differences between bone and metallic materials could lead to mechanical issues at the bone-implant interface, as stress shielding. Those issue are mainly related to knee and hip arthroplasty, and they could be responsible for implant failure. To reduce mismatching-related adverse events between bone and prosthesis mechanical properties, modifying the implant's internal geometry varying the bulk stiffness and density could be the right approach. Therefore, this feasibility study aims to assess which in-body gap geometry improves, by reducing, the bulk stiffness. Methods: Using five finite element models, a unia…

Elastic ModulusArthroplasty Replacement HipIn-body gapsFinite Element AnalysisFeasibility StudiesHealth InformaticsStress MechanicalArthroplasty Replacement KneeSoftwareComputer Science ApplicationsMaterial stiffness
researchProduct

Numerical simulations on periprosthetic bone remodeling: a systematic review

2021

Abstract Background and objective The aim of the present study was to review the literature concerning the analysis of periprosthetic bone remodeling through finite element (FE) simulation. Methods A systematic review was conducted on 9 databases, taking into account a ten-year time period (from 2009 until 2020). The inclusion criteria were: articles published in English, publication date after 2009, full text articles, articles containing the keywords both in the abstract and in the title. The articles were classified through the following parameters: dimensionality of the simulation, modelling of the bone-prosthesis interface, output parameters, type of simulated prosthesis, bone remodeli…

Bone densityComputer scienceFinite Element AnalysisPeriprostheticHealth InformaticsProsthesisModels Biological030218 nuclear medicine & medical imagingBone remodeling03 medical and health sciences0302 clinical medicineFE simulationsBone DensityFemurComputer SimulationComputational analysisFemurComputational analysisOrthodonticsBiological processesComputer Science ApplicationsBiological processes Computational analysis Systematic review FE simulations Bone remodeling ProsthesisSystematic reviewBone Remodeling030217 neurology & neurosurgerySoftware
researchProduct

Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis

2023

The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symm…

transfemoral amputation; osseointegration; socket-type; biomechanics; wearable sensors; gait analysis; gait symmetry; case reportElectrical and Electronic EngineeringSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeBiochemistryInstrumentationbiomechanics case report gait analysis gait symmetry osseointegration socket-type transfemoral amputation wearable sensorsAtomic and Molecular Physics and OpticsAnalytical ChemistrySensors
researchProduct

Biomechanical Analysis of a New Elbow Prosthesis

2019

Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model…

musculoskeletal diseasesTotal elbow arthroplasty FEM Reverse engineering CADFEM030222 orthopedicsbusiness.industryElbowAseptic looseningDentistry030229 sport sciencesmusculoskeletal systemElbow prosthesisTotal elbow arthroplasty03 medical and health sciences0302 clinical medicinemedicine.anatomical_structuremedicineTotal elbow arthroplastyCADImplantSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse engineeringbusiness
researchProduct

Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach

2020

Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…

musculoskeletal diseasesMaterials sciencemedicine.medical_treatmentHealing timelcsh:TechnologyStability (probability)Locking platelcsh:Chemistry03 medical and health sciences0302 clinical medicinemedicineCADGeneral Materials Science030212 general & internal medicineTibial fractureSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria Industrialelcsh:QH301-705.5InstrumentationReduction (orthopedic surgery)implant stabilityFluid Flow and Transfer ProcessesOrthodonticsFEM030222 orthopedicslcsh:TProcess Chemistry and TechnologyWork (physics)General Engineeringtibial fracturemusculoskeletal systemlocking plateslcsh:QC1-999Finite element methodComputer Science Applicationsreverse engineeringlcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Proper treatmentlcsh:Engineering (General). Civil engineering (General)lcsh:PhysicsLocking plateApplied Sciences
researchProduct

Virtual simulation of an osseointegrated trans-humeral prosthesis: A falling scenario

2018

Abstract Introduction Traditional prosthetic solutions expose the amputee to numerous problems that limit his ability to safely perform the normal activities of daily life. In order to eliminate the problems related to the use of the traditional prosthesis with socket, a new technique was developed for fixing the prosthesis to the amputees based on the principle of osseointegration. The aim of this paper is to study and analyze the stress distribution on the interface between a trans-humeral osseointegrated prosthetic implant and the residual bone, identifying the most stressed areas and thus foreseeing possible failure phenomena of the entire prosthetic system and, after, to compare the st…

Finite element methodFinite Element Analysis0206 medical engineeringArtificial LimbsHumeru02 engineering and technologyThread (computing)FixtureProsthesis DesignOsseointegration prosthesis FE AnalysisOsseointegrationProsthesis Implantation03 medical and health sciencesAmputeeFinite Element Analysi0302 clinical medicineAmputeesOsseointegrationBone-Implant InterfaceHumansProsthesivon Mises yield criterionMedicineTorqueComputer SimulationOrthopedics and Sports MedicineForce platformUpper limbOsseointegration Prosthesis Amputees Upper limb Finite element methodSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeSimulationGeneral Environmental Science030222 orthopedicsbusiness.industryAccidental FallArtificial LimbHumerus020601 biomedical engineeringBiomechanical PhenomenaReactionEmergency MedicineBending momentGeneral Earth and Planetary SciencesAccidental FallsStress MechanicalbusinessHuman
researchProduct

A New Approach for CAD Modelling of Customised Orthoses by Generative Design

2021

The standard method of design and manufacturing customised orthoses is still very time-consuming due to their often very complex shape. Different authors have tried to solve this problem but, unfortunately, the proposed approaches cannot be easily used in clinical practice because they require substantial interaction among medical staff and engineers or technicians. The aim of this work is to present the framework of a new design approach that could allow clinicians to easily model a customised orthosis, without a skilled technician develops the entire procedure. In particular, an automatic process based on Generative Design has been implemented. The obtained results have demonstrated that …

Engineering drawingGenerative designComputer scienceCustomised orthosiCADCADCustomised orthosisGenerative DesignSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse engineering
researchProduct

Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences

2020

Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…

musculoskeletal diseasesmedicine.medical_specialtyKinematicsKnee Jointmedicine.medical_treatmentComparisonKinematicsPromProsthesis DesignProsthesis03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicinePosterior-stabilized kneeRange of Motion ArticularSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeArthroplasty Replacement KneeOrthodontics030222 orthopedicsKnee laxitybusiness.industryTKAPosterior stabilized030229 sport sciencesKinematicmusculoskeletal systemNavigationBiomechanical PhenomenaSurgeryCohortOrthopedic surgerySurgeryMobile bearingKnee ProsthesisRange of motionbusinessMUSCULOSKELETAL SURGERY
researchProduct

Biomechanical analysis of two types of osseointegrated transfemoral prosthesis

2020

In the last two decades, osseointegrated prostheses have been shown to be a good alternative for lower limb amputees experiencing complications in using a traditional socket-type prosthesis

Computer sciencemedicine.medical_treatmentFinite element analysi0206 medical engineeringOPLProsthetic limb02 engineering and technologyProsthesislcsh:TechnologyOsseointegrationlcsh:Chemistry03 medical and health sciencesDistal femur0302 clinical medicineosseointegrated prosthesismedicineGeneral Materials ScienceCADOPL osseointegrated prosthesiSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeInstrumentationlcsh:QH301-705.5Fluid Flow and Transfer ProcessesOrthodontics030222 orthopedicslcsh:TProcess Chemistry and TechnologyGeneral EngineeringFinite element analysisOPL osseointegrated prosthesisLimitingStress distributionTransfemoral amputeeequipment and supplies020601 biomedical engineeringTransfemoral prosthesislcsh:QC1-999OPRAComputer Science Applicationsbody regionslcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Implantlcsh:Engineering (General). Civil engineering (General)lcsh:Physics
researchProduct