6533b7d3fe1ef96bd1260110
RESEARCH PRODUCT
Assessment of paradoxical anterior translation in a CR total knee prosthesis coupling dynamic RSA and FE techniques
Stefano ZaffagniniRaffaele ZinnoAgostino Igor MirullaAgostino Igor MirullaBernardo InnocentiLaura BragonzoniTommaso Ingrassiasubject
medicine.medical_specialtyKinematicsmedicine.medical_treatmentKinematicsRotationTranslation (geometry)ProsthesisCondyleTotal knee03 medical and health sciences0302 clinical medicineMobile bearingmedicineCoupling (piping)Orthopedics and Sports MedicineARTHROPLASTYMathematicsTKA FEATURESOrthodonticsOrthopedic surgery030222 orthopedicsOriginal PaperScience & TechnologyTKAGénéralités030229 sport sciencesDynamic RSAKinematicOrthopedicsOrthopedic surgerySurgeryFE analysiFE analysisLife Sciences & BiomedicineRD701-811description
Purpose: The study aims were to assess the kinematic data, Internal-External (IE) rotation, and Antero-Posterior (AP) translation of the contact points between the femoral condyles and polyethylene insert and to develop a combined dynamic RSA-FE (Radiostereometric – Finite Element) model that gives results congruent with the literature. Methods: A cohort of 15 patients who underwent cemented cruciate-retaining highly congruent mobile-bearing total knee arthroplasty were analyzed during a sit-to-stand motor task. The kinematical data from Dynamic RSA were used as input for a patient-specific FE model to calculate condylar contact points between the femoral component and polyethylene insert. Results: The femoral component showed an overall range about 4 mm of AP translation during the whole motor task, and the majority of the movement was after 40° of flexion. Concerning the IE rotation, the femoral component started from an externally rotate position (− 6.7 ± 10°) at 80° of flexion and performed an internal rotation during the entire motor task. The overall range of the IE rotation was 8.2°. Conclusions: During the sit to stand, a slight anterior translation from 40° to 0° of flexion of the femoral component with respect to polyethylene insert, which could represent a paradoxical anterior translation. Despite a paradoxical anterior femoral translation was detected, the implants were found to be stable. Dynamic RSA and FE combined technique could provide information about prosthetic component’s stress and strain distribution and the influence of the different designs during the movement.
year | journal | country | edition | language |
---|---|---|---|---|
2021-07-10 |