Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns
2019
Background The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. Material and methods 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then e…
Effect of prefabricated thermoformable foot orthoses on plantar surface temperature after running: A gender comparison.
2020
Abstract There is a lack of evidence about the effect of different type of foot orthoses on plantar surface temperature. Moreover, that effect could be different depending on gender due to anatomical and physiological differences between men and women. The aim of the study was to analyze the effect of a prefabricated thermoformable foot orthosis on plantar surface temperature after running and taking gender differences into account. Thirty recreational runners (15 males, mean (standard deviation): 28 (7) years, 69.7 (6.5) kg, 1.74 (0.05) cm and 22.9 (1.7) kg/m2; and 15 females: 35 (7) years, 55.2 (6.9) kg, 1.63 (0.06) cm and 20.6 (1.9) kg/m2) carried out a maximum incremental test as pre-te…
Dental wear proxy correlation in a long-term feeding experiment on sheep ( Ovis aries )
2021
Dietary reconstruction in vertebrates often relies on dental wear-based proxies. Although these proxies are widely applied, the contributions of physical and mechanical processes leading to meso- and microwear are still unclear. We tested their correlation using sheep ( Ovis aries , n = 39) fed diets of varying abrasiveness for 17 months as a model. Volumetric crown tissue loss, mesowear change and dental microwear texture analysis (DMTA) were all applied to the same teeth. We hereby correlate: (i) 46 DMTA parameters with each other, for the maxillary molars (M1, M2, M3), and the second mandibular molar (m2); (ii) 10 mesowear variables to each other and to DMTA for M1, M2, M3 and m2; and (…
Modular Wear Facet Nomenclature for mammalian post-canine dentitions
2017
Dental wear facets on the occlusal surface of premolars and molars are traces of their main function, the mastication and therefore reflect masticatory movements and also paramasticatory (i.e. non-dietary use of teeth) behavior. Here we present the Modular Wear Facet Nomenclature applicable to most mammalian dentitions. Topographic positions of wear facets in relation to the major cusps and crests of the teeth are used to designate the areas of the occlusal surface the facets occupy (e.g. their mesial, distal, lingual, or buccal position). Previous published systems for labeling wear facets have been inconsistent with each other. Therefore, we provide a synoptic review of the most widely-us…
Impact loading history modulates hip fracture load and location : A finite element simulation study of the proximal femur in female athletes
2018
Sideways falls impose high stress on the thin superolateral cortical bone of the femoral neck, the region regarded as a fracture-prone region of the hip. Exercise training is a natural mode of mechanical loading to make bone more robust. Exercise-induced adaptation of cortical bone along the femoral neck has been previously demonstrated. However, it is unknown whether this adaption modulates hip fracture behavior. The purpose of this study was to investigate the influence of specific exercise loading history on fall-induced hip fracture behavior by estimating fracture load and location with proximal femur finite element (FE) models created from magnetic resonance images (MRI) of 111 women w…
In vitro comparison of primary stability of two implant designs in D3 bone
2016
Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…
Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: an i…
2016
Background: Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. Material and Methods: 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate th…
Surgically-oriented anatomical study of mandibular premolars: A CBCT study
2019
Background The knowledge of root canal anatomy and of the anatomical relationship should be considered mandatory when planning surgical endodontics. The aim of the study was to investigate the anatomical features of mandibular premolars, evaluating their relationship with mental nerve. Material and methods CBCT scans were evaluated recording the number of roots, root canal configuration and the relationship with mental nerve of 100 mandibular premolars. After simulating a resection of 3 mm of the root, the shape and the number of canals, and the distance to the buccal and lingual bone plate and to the mental foramen was evaluated. Results The one root - one canal configuration was the most …
Reasons for extraction in primary teeth among 5-12 years school children in Haryana, India- A cross-sectional study
2017
Background Due to high prevalence of oral diseases extraction of primary teeth is a common and a major concern in developing countries. These teeth are given least importance as they are believed to shed off automatically, thus leading to serious problems like crowding and malocclusion. Material and methods A cross sectional study was carried out among children aged 5 to 12 years among 1347 children. The data was recorded on a prestructured questionnaire. Reasons for extraction of teeth were based on Kay and Blinkhorn criteria. Results 20.4% children were having tooth loss due to various reasons. The main reason for extraction was found to be caries in 64.3% followed by trauma in maxillary …
Chronic nail biting, orthodontic treatment and Enterobacteriaceae in the oral cavity
2019
Background Chronic nail biting is common in children and young adults. Auto inoculation of environmental pathogens can manifest as infection in distant organs. Multi-drug resistance gram negative bacteria are on the rise globally. Several of the foodborne bacteria fall within the Enterobacteriaceae family but very few studies have explored these microbes in the oral cavity of children with chronic nail-biting habit or orthodontic treatment. The study aims to investigate oral load of Enterobacteriaceae in children with chronic nail-biting habit and or those undergoing orthodontic treatment. Material and methods 150 children (no nail-biting n=30, nail biting n=60, fixed orthodontic treatment …