6533b7d3fe1ef96bd1260b8b
RESEARCH PRODUCT
Effect of prefabricated thermoformable foot orthoses on plantar surface temperature after running: A gender comparison.
Inmaculada AparicioJose Ignacio Priego-quesadaIrene Jimenez-perezRosa Mª Cibrián Ortiz De AndaMarina Gil-calvoPedro Pérez-sorianosubject
0106 biological sciencesAdultMalebusiness.product_categoryHeelPhysiology030310 physiologyPlantar surfaceFoot Orthoses010603 evolutionary biology01 natural sciencesBiochemistryRunning03 medical and health sciencesRandom AllocationSex FactorsmedicineHumansTreadmillFoot OrthosesGender comparisonFoot orthosisOrthodontics0303 health sciencesbusiness.industryFootIncremental testShoesmedicine.anatomical_structureFemaleGeneral Agricultural and Biological SciencesbusinessSkin TemperatureFoot (unit)Developmental Biologydescription
Abstract There is a lack of evidence about the effect of different type of foot orthoses on plantar surface temperature. Moreover, that effect could be different depending on gender due to anatomical and physiological differences between men and women. The aim of the study was to analyze the effect of a prefabricated thermoformable foot orthosis on plantar surface temperature after running and taking gender differences into account. Thirty recreational runners (15 males, mean (standard deviation): 28 (7) years, 69.7 (6.5) kg, 1.74 (0.05) cm and 22.9 (1.7) kg/m2; and 15 females: 35 (7) years, 55.2 (6.9) kg, 1.63 (0.06) cm and 20.6 (1.9) kg/m2) carried out a maximum incremental test as pre-test, and two running tests on a treadmill at the laboratory wearing previously randomized different foot orthoses (thermoformable and prefabricated generic). The plantar surface temperature of the dominant foot sole in ten regions of interest was assessed before and immediately after 30-min running at 75% of VO2max. The use of thermoformable foot orthoses produced lower temperatures only in men after the run in medial heel (P = 0.033, ES = 0.7), which then disappeared in temperature variation (after – before) (P = 0.910). Regarding gender, women showed lower temperatures before the run in both orthosis conditions (P 0.8), but no differences in temperatures after the run (P = 0.910) in comparison with men. Moreover, absolute temperatures after running were always greater than before the run (P 5.0). In conclusion, the thermoformable foot orthoses do not modify plantar surface temperature after running in healthy runners of either gender, compared to prefabricated generic foot orthoses. Although women present lower baseline plantar temperatures than men, these differences disappear after exercise.
year | journal | country | edition | language |
---|---|---|---|---|
2020-01-31 | Journal of thermal biology |