0000000000076899

AUTHOR

Stefano Zaffagnini

Advanced microscopy analysis of the micro-nanoscale architecture of human menisci

AbstractThe complex inhomogeneous architecture of the human meniscal tissue at the micro and nano scale in the absence of artefacts introduced by sample treatments has not yet been fully revealed. The knowledge of the internal structure organization is essential to understand the mechanical functionality of the meniscus and its relationship with the tissue’s complex structure. In this work, we investigated human meniscal tissue structure using up-to-date non-invasive imaging techniques, based on multiphoton fluorescence and quantitative second harmonic generation microscopy complemented with Environmental Scanning Electron Microscopy measurements. Observations on 50 meniscal samples extract…

research product

Assessment of paradoxical anterior translation in a CR total knee prosthesis coupling dynamic RSA and FE techniques

Purpose: The study aims were to assess the kinematic data, Internal-External (IE) rotation, and Antero-Posterior (AP) translation of the contact points between the femoral condyles and polyethylene insert and to develop a combined dynamic RSA-FE (Radiostereometric – Finite Element) model that gives results congruent with the literature. Methods: A cohort of 15 patients who underwent cemented cruciate-retaining highly congruent mobile-bearing total knee arthroplasty were analyzed during a sit-to-stand motor task. The kinematical data from Dynamic RSA were used as input for a patient-specific FE model to calculate condylar contact points between the femoral component and polyethylene insert. …

research product

Analysis of different geometrical features to achieve close-to-bone stiffness material properties in medical device: A feasibility numerical study

Background and objective: In orthopedic medical devices, elasto-plastic behavior differences between bone and metallic materials could lead to mechanical issues at the bone-implant interface, as stress shielding. Those issue are mainly related to knee and hip arthroplasty, and they could be responsible for implant failure. To reduce mismatching-related adverse events between bone and prosthesis mechanical properties, modifying the implant's internal geometry varying the bulk stiffness and density could be the right approach. Therefore, this feasibility study aims to assess which in-body gap geometry improves, by reducing, the bulk stiffness. Methods: Using five finite element models, a unia…

research product

Numerical simulations on periprosthetic bone remodeling: a systematic review

Abstract Background and objective The aim of the present study was to review the literature concerning the analysis of periprosthetic bone remodeling through finite element (FE) simulation. Methods A systematic review was conducted on 9 databases, taking into account a ten-year time period (from 2009 until 2020). The inclusion criteria were: articles published in English, publication date after 2009, full text articles, articles containing the keywords both in the abstract and in the title. The articles were classified through the following parameters: dimensionality of the simulation, modelling of the bone-prosthesis interface, output parameters, type of simulated prosthesis, bone remodeli…

research product

Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis

The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symm…

research product

How preconditioning and pretensioning of grafts used in ACLigaments surgical reconstruction are influenced by their mechanical time-dependent characteristics: Can we optimize their initial loading state?

Abstract Purpose Consensus about a pre-implant preparation protocol adaptable to any graft used in Anterior Cruciate Ligament reconstruction is still lacking. In fact, there is not agreement on reliable metrics that consider both specific graft dimensional characteristics, such as its diameter, and the inherent properties of its constitutive material, i.e. ligaments or tendons. Aim of the present study was to investigate and propose the applied engineering stress as a possible metrics. Methods Preconditioning and pretensioning protocol involved groups of grafts with different section (10 or 32 mm2) and materials (i.e. human patellar and hamstring tendons, and synthetic grafts). A 140 N load…

research product

Reduced-dose computed tomography is the most accurate method to measure ceramic hip resurfacing cup version

Background: A precise assessment of cup version after hip resurfacing is generally requested, especially in clinical trials or in case of complications. Aims: To identify which diagnostic imaging modality, between AP pelvis X-rays, the AP Pelvis CT Scout image and reduced-dose axial CT scan, is the most precise to assess cup version of an all-ceramic hip resurfacing implant in a first-in-human clinical trial. Methods: We retrospectively assessed the cup version of the first 20 patients who underwent an experimental all-ceramic hip resurfacing on AP pelvis X-rays (0.8 mSv of radiation), AP pelvis CT scout images (0.016 mSv) and axial CT slices performed using a reduced dose protocol (0.3 mSv…

research product

Virtual simulation of an osseointegrated trans-humeral prosthesis: A falling scenario

Abstract Introduction Traditional prosthetic solutions expose the amputee to numerous problems that limit his ability to safely perform the normal activities of daily life. In order to eliminate the problems related to the use of the traditional prosthesis with socket, a new technique was developed for fixing the prosthesis to the amputees based on the principle of osseointegration. The aim of this paper is to study and analyze the stress distribution on the interface between a trans-humeral osseointegrated prosthetic implant and the residual bone, identifying the most stressed areas and thus foreseeing possible failure phenomena of the entire prosthetic system and, after, to compare the st…

research product

Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences

Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…

research product

Graft Healing in ACL Reconstruction: Can We Enhance It in Clinical Practice?

The ACL-Deficient Knee: A Problem Solving Approach, focuses on problem analysis and problem solving, as well as analyzing the possibility of prevention. In each chapter, the biomechanics, anatomy, etc. that are relevant to the topic are reviewed. There are chapters where highly specialized surgical techniques are presented (v. gr. double bundle reconstruction or meniscal transplant), as well as developing areas such as ACL tears in children, where we are finding a growing number of injuries due to the increase of sports at early ages Surgical reconstruction of the anterior cruciate ligament (ACL) using tendon grafts is the current standard to treat the functionally ACL-deficient knee. The s…

research product

Biomechanical analysis of two types of osseointegrated transfemoral prosthesis

In the last two decades, osseointegrated prostheses have been shown to be a good alternative for lower limb amputees experiencing complications in using a traditional socket-type prosthesis

research product