6533b821fe1ef96bd127ae3f
RESEARCH PRODUCT
How preconditioning and pretensioning of grafts used in ACLigaments surgical reconstruction are influenced by their mechanical time-dependent characteristics: Can we optimize their initial loading state?
Massimiliano ZingalesMatteo BerniStefano ZaffagniniDoriana SpadaroEmanuela BolognaMarianna ZitoAndrea VisaniNicola LopomoLawrence CamardaGregorio Marchiorisubject
Anterior cruciate ligament reconstructionKnee JointComputer scienceAnterior cruciate ligamentmedicine.medical_treatmentBiophysicsPreconditioningStress (mechanics)TendonsGraft03 medical and health sciences0302 clinical medicinePretensioningStress relaxationmedicineHumansOrthopedics and Sports MedicineAnterior cruciate ligament; Graft; Preconditioning; Pretensioning; Stress relaxationStress relaxationAnterior Cruciate LigamentTendon030222 orthopedicsAnterior Cruciate Ligament ReconstructionAnterior Cruciate Ligament InjuriesAnterior Cruciate Ligament InjurieStiffness030229 sport sciencesPatellaBiomechanical Phenomenamedicine.anatomical_structureKnee laxityEngineering stressHamstring Tendonsmedicine.symptomBiomedical engineeringHumandescription
Abstract Purpose Consensus about a pre-implant preparation protocol adaptable to any graft used in Anterior Cruciate Ligament reconstruction is still lacking. In fact, there is not agreement on reliable metrics that consider both specific graft dimensional characteristics, such as its diameter, and the inherent properties of its constitutive material, i.e. ligaments or tendons. Aim of the present study was to investigate and propose the applied engineering stress as a possible metrics. Methods Preconditioning and pretensioning protocol involved groups of grafts with different section (10 or 32 mm2) and materials (i.e. human patellar and hamstring tendons, and synthetic grafts). A 140 N load was applied to the grafts and maintained for 100 s. Initial stress and following stress-relaxation (a mechanical characteristic that can be related to knee laxity) were specifically analysed. Findings Initial stress, ranging between 4 and 12 MPa, was affected primarily by the graft cross-section area and secondarily by the choice of the graft material. In terms of loss of the initial stress, stress-relaxation behaviour varied instead on a narrower range, namely 13–17%. Interpretation Engineering stress can be identified as the correct metrics to optimize the initial state of each graft to avoid excessive stiffness, laxity or fatigue rupture phenomena.
year | journal | country | edition | language |
---|---|---|---|---|
2021-01-01 |