0000000000003710

AUTHOR

Milton T.w. Hearn

High-performance liquid chromatography of amino acids, peptides and proteins

Abstract The thermodynamic constants, associated with the interaction of three proteins with triazine dye affinity sorbents, have been derived from bath and frontal analysis experiments. In cases where mass-transfer restrictions are very high, calculation of the thermodynamic constants directly from frontal analysis experiments could not be achieved. In such cases, a portion of the adsorbate was always present in the effluent, a situation which has its effect as the split peak phenomenon. With Fractogel-based triazine dye affinity sorbents none of the test proteins applied in frontal analysis were adsorbed. A similar behaviour was observed for a Cellufine sorbent during the adsorption of hu…

research product

Evaluation of advanced silica packings for the separation of biopolymers by high-performance liquid chromatography

Following previous studies of the use of non-porous monodisperse 1.5-microns n-octyl- and n-octadecyl-bonded silicas in gradient elution of proteins, this work was aimed at elucidating further the properties of this novel column material for peptide and protein separations in comparison with wide-pore silicas. First, it is demonstrated that with short columns (e.g., 35 X 8 mm I.D.) packed with these non-porous reversed-phase materials, mixtures of small peptides and mixtures of proteins can be very efficiently resolved. When the chain length of the bonded ligand was varied, the retention of a test set of proteins in gradient elution followed the ligand sequence C18 greater than C8 approxima…

research product

Capillary electroendoosmotic chromatography of peptides

This review focuses on the current state of peptide separation by capillary electroendoosmotic chromatography (CEC). When carried out under optimised conditions, peptide separation by CEC methods represents an orthogonal and complementary technique to micro-HPLC (micro-HPLC) and high-performance capillary zone electrophoresis (HPCZE). The origin of the selectivity differences that can be achieved with these three separation techniques (CEC, micro-HPLC and HPCZE), respectively are discussed, and the current limits of performance with CEC methods documented. Peptide separations by CEC methods with n-alkyl bonded silicas or mixed-mode phases are also illustrated. The development of different v…

research product

Evaluation of advanced silica packings for the separation of biopolymers by high-performance liquid chromatography

Abstract The reversed-phase chromatography of proteins by gradient elution with acidic, low-ionic-strength aqueous—organic eluents is often associated with losses of the biological activity of the protein. In this study, the enzymatic activities of catalase, horseradish peroxidase and pepsin were examined under static and dynamic column conditions on non-porous, monodisperse 1.5-μm reversed-phase silicas with various n -alkyl ligands. Catalase readily lost its enzymatic activity under the influence of the acidic aqueous—organic eluents in the absence of the reversed-phase packing, whereas peroxidase was partially deactivated as a result of combined mobile phase and stationary phase effects …

research product

Capillary electrochromatography analysis of hormonal cyclic and linear peptides.

The retention behavior of linear and cyclic peptides has been studied by capillary electrochromatography (CEC) with a variety of different n-alkyl silica reversed-phase sorbents and also with mixed-mode phases containing both strong cation-exchange (sulfonic acid) and n-alkyl groups bonded onto the silica surface, using eluents ranging from pH 2.0 to pH 5.0. Depending upon the amino acid sequence, electrochromatographic retention of the peptides was strongly affected by the composition of the eluent, its pH value, and the choice of sorbent packed into the capillaries. The dominant separation processes operating with these charged analytes could be modulated inter alia by the content of orga…

research product

A critical appraisal of capillary electrochromatography.

Although still in its infancy, CEC promises some advantages over competitive techniques for separating charged analytes including biomolecules.

research product

Influence of ligand density on the properties of metal-chelate affinity supports.

A new procedure has been developed to immobilize iminodiacetic acid (IDA) onto the surface of silica supports, such as LiChrospher Si-1000 and 1.5-microns nonporous silica, for use in high-performance immobilized metal affinity chromatography (HPIMAC) of proteins. This IDA immobilization method has been achieved through the synthesis of a new silylation reagent, 1-(iminodiacetic acid di-tert-butylester)-3-glycidoxy-propyltrimethoxysilane (IDA-silane). Various modified silicas of different ligand densities have been prepared by using mixtures between 1 and 100% of the IDA-silane diluted with the corresponding 3-glycidoxy-propyltrimethoxysilane (GLYMO-silane). Frontal analysis was used with t…

research product

Retention behaviour of paracelsin peptides on reversed-phase silicas with varying n-alkyl chain length and ligand density.

As part of further investigations on the characterization of the ligand-induced conformational stabilization of peptides, two series of n-alkyldimethylsilyl bonded silicas have been prepared. In series A the n-alkyl chain length, n, of the bonded phase was varied between 1 and 20 carbon atoms at a constant ligand density. In series B the ligand density, alpha exp, was gradually changed from 0 to 4.1 mumol/m2 on a C1, C4, C6, C8 and C18 bonded phase. The retention behaviour of four peptides of the paracelsin family were examined under isocratic conditions, using a ternary mobile phase of water-methanol-acetonitrile (22:39:39, v/v/v). Plots of k' versus n showed pronounced maxima between n = …

research product

The CEC behaviour of several synthetic peptides related to the activin ��A-��D subunits

The resolution of several structurally related synthetic peptides, derived from the loop 3 region of the activin betaA-betaD subunits, has been studied using capillary electrochromatography (CEC) with Hypersil n-octadecylsilica as the sorbent. The results confirm that the CEC migration of these peptides can be varied in a charge-state-specific manner as the properties of the background electrolyte, such as pH, salt concentration and content of organic modifier, or temperature are systematically changed. Acidic peptides followed similar trends in retention behaviour, which was distinctly different to that shown by more basic peptides. The CEC separation of these peptides with the Hypersil n-…

research product

Affinity chromatography with triazine dyes immobilized onto activated non-porous monodisperse silicas

Abstract Non-porous monodisperse silicas with a particle diameter of 2.1 μm were modified with different silanes for immobilization of various triazine dyes including Procion Red HE3B, Procion Red MX5B, and Cibacron Blue F3GA. Lactate dehydrogenase and malate dehydrogenase from different species and aldehyde reductase from rat brain were purified by affinity elution using the substrate of the enzyme and NADH. With Cibacron F3GA the selectivity for NADH-dependent enzymes was higher than with the two Procion dyes. The utility of these immobilized triazine dye systems on non-porous silica supports for the rapid separation of Cohn Fraction III plasma proteins, including plasminogen, is also des…

research product

Separation of selected peptides by capillary electroendoosmotic chromatography using 3 μm reversed-phase bonded silica and mixed-mode phases

The retention behaviour and selectivity of selected basic, neutral and acidic peptides have been studied by capillary electroendoosmotic chromatography (CEC) with Hypersil C8, C18, Hypersil mixed-mode, and Spherisorb C18/SCX columns, 250 (335) mm x 100 microns, packed with 3 microns particles, and eluted with mobile phases composed of acetonitrile-triethylamine-phosphoric acid (TEAP) at pH 3.0 using a Hewlett-Packard Model HP3DCE capillary electrophoresis system. The selected peptides were desmopressin (D), two analogues (A and B) of desmopressin, oxytocin (O) and carbetocin (C). The peptides eluted either before or after the electroendoosmotic flow (EOF) marker, depending on the concentrat…

research product

Life-time studies with capillary electrochromatography columns operated under different conditions.

A test system has been established to permit the monitoring of the life-time performance of several reversed- phase capillary electrochromatography (CEC) columns. The retention factors, k(cec), peak symmetry coefficients, lambda(sym), and column efficiencies, N, of three neutral n-alkylbenzene analytes, namely ethyl-, n-butyl- and n-pentylbenzenes, were determined for Hypersil 3 microm n-octylsilica and n-octadecylsilica packed into CEC capillary columns of 100 microm I.D., with a packed length of 250 mm, and a total length of 335 mm. The performances of these CEC capillary columns were examined for a variety of eluents with pH values ranging between pH 2.0 - 8.0, similar to those employed …

research product

On the nature of the forces controlling selectivity in the high performance capillary electrochromatographic separation of peptides

In this minireview, the nature of the forces controlling selectivity in the high performance capillary electrochromatographic (HP-CEC) separation of peptides has been examined. For uncharged and charged peptides, a synergistic interplay occurs in HP-CEC systems between adsorptive/partitioning events and electrokinetically driven motion. Moreover, at high field strengths, both bulk electrophoretic migration and surface electrodiffusion occur. Thus, the migration behavior of peptides in different HP-CEC systems can be rationalized in terms of the combined consequences of these various processes. Moreover, in HP-CEC, the buffer electrolyte interacts with both the peptide analytes and the sorbe…

research product

Application of CEC procedures for the analysis of synthetic peptides: characterization of linear immunogenic peptides that mimic a HIV-1 gp120 epitope

In this study, we describe the application of a new analytical procedure based on capillary electrochromatographic(CEC) techniques for the characterization of different basic and acidic peptides using isocratic eluent conditions containing acetonitrile and ammonium acetate buffers of different molarities between pH 3.8 and 5.2. In particular,10 immunogenic peptide analogs with isoelectric points ranging from 3.7 to 10.1 were investigated; nine of these peptides, 1-9, were truncated analogs of the parent peptide, 10, which is a peptidomimetic related to a HIV-1 gp120 epitope. Several of these peptides have the propensity to form alpha-helical secondary structures in solution. Electrochromato…

research product

Influence of temperature on the behaviour of small linear peptides in capillary electrochromatography

The influence of temperature, T, on the retention times, peak widths, peak symmetry coefficients and theoretical plate numbers of two small linear peptides, [Met5]enkephalin and [Leu5]enkephalin, has been studied with capillary electrochromatography (CEC) capillary columns of 100 microm I.D. and 250 mm packed length with a total length of 335 mm, containing 3 microm Hypersil n-octadecyl bonded silica. With increasing column temperature from 15 to 60 degrees C, the electroosmotic flow (EOF) and the column efficiencies increased, whereas the retention coefficients (Kcec) of both peptides decreased. A linear relationship was found between the EOF value and the square root of the temperature ov…

research product

Evaluation of advanced silica packings for the separation of biopolymers by high-perforamnce liquid chromatography

Non-porous monodisperse 1.5-μm silicas were allowed to react with (A) and (B) N-acetylaminopropyltriethoxysilane to generate bonded phases useful in high-performance hydrophobic-interaction chromatography (HIC). Differences in the selectivity were observed between he amide and the ether phase. Peak capacities between 10 and 30 were achieved for several proteins with the amide and ether phase packed into columns of 36 × 8 mm I.D. and elution of the proteins under chromatographic conditions in which the gradient volume, VG, was held constant by varying the gradient time between 20 and 2.5 min and the flow-rate between 0.5 and 4.0 ml/min. The S values derived from the dependences of log k′ on …

research product

Adsorption of proteins on porous and non-porous poly(ethyleneimine) and tentacle-type anion exchangers

Abstract Adsorption isotherms of proteins [bovine serum albumin (BSA), soybean trypsin inhibitor and alcohol dehydrogenase] on anion exchangers were measured by on-line and off-line methods. The poly(ethyleneimine) (PEI) type and the tentacle-type materials exhibited principally different modes of adsorption. On thin layers of PEI, bonded to non-porous silica, BSA adsorption data corresponded to a monolayer of molecules, with 80% adsorbed side-on, with a high affinity constant for binding, and 20% adsorbed more weakly. With porous material, the amount of BSA bound per unit surface with high affinity was smaller. With tentacle-type anion exchangers, adsorption exceeded a monolayer by far, an…

research product