0000000000003876

AUTHOR

Sophie Kazamias

showing 11 related works from this author

High-brilliance double-stage soft x-ray laser pumped by multiple pulses applied in grazing incidence

2014

A new compact scheme for a double-stage seeded x-ray laser is demonstrated. This laser is offering greatly improved beam quality and brilliance making it a useful tool for applications.

HistorySoft x rayMaterials sciencebusiness.industryLaserComputer Science ApplicationsEducationlaw.inventionOpticslawPhysics::Accelerator PhysicsOptoelectronicsPhysics::Atomic PhysicsLaser beam qualityLaser power scalingbusinessDouble stageIncidence (geometry)Journal of Physics: Conference Series
researchProduct

An Improved Double-Pulse Non-Normal Incidence Pumping Geometry for Transient Collisionally Excited Soft X-Ray Lasers

2009

An optimized pumping geometry for transient collisionally excited soft X-ray lasers is presented, similar to the geometry proposed by [1]. In contrast to usual approaches, where a nanosecond pre-pulse is assumed to provide the optimal plasma preparation and a picosecond pulse performs the final heating- and excitation process, two pulses of equal duration in the range around 10 picoseconds are applied. Both pulses are produced in the front end of the CPA pump laser. They are focused onto the target with the same spherical mirror under non-normal incidence geometry, optimized for efficient traveling wave excitation for the main-pulse. A first experiment was performed on Ni-like palladium (14…

Physicsbusiness.industryCurved mirrorGeometryLaser pumpingNanosecondLaserlaw.inventionOpticsRegenerative amplificationlawPicosecondExcited statebusinessExcitation
researchProduct

Double-pulse single-beam grazing-incidence pumping

2011

The paper reports on the optimization of a table-top nickel-like molybdenum transient collisionally excited soft x-ray laser (SXRL) at 18.9 nm, performed by double-pulse single beam grazing incidence pumping (DGRIP) [1]. This scheme allows for the first time the full control of the pump laser parameters including the pre-pulse duration, optimally generating the SXRL amplifier under grazing incidence. The single beam geometry of collinear double-pulse propagation guarantees the ideal overlap of the pre- and main pulse from shot to shot, resulting in a more efficient, highly stable SXRL output. SXRL energies up to 2.2 µJ are obtained with a total pump energy less than 1 J for several hours at…

Materials sciencebusiness.industryAmplifierPulse durationLaser pumpingLaserlaw.inventionPulse (physics)OpticslawExcited stateTransient (oscillation)businessEnergy (signal processing)
researchProduct

Short-wavelength soft-x-ray laser pumped in double-pulse single-beam non-normal incidence

2010

We demonstrated a $7.36$ nm Ni-like samarium soft-x-ray laser, pumped by $36$ J of a neodymium:glass chirped-pulse amplification laser. Double-pulse single-beam non-normal-incidence pumping was applied for efficient soft-x-ray laser generation. In this case, the applied technique included a single-optic focusing geometry for large beam diameters, a single-pass grating compressor, traveling-wave tuning capability, and an optimized high-energy laser double pulse. This scheme has the potential for even shorter-wavelength soft-x-ray laser pumping.

PhysicsDistributed feedback laserbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaFar-infrared laserPhysics::OpticsLaser pumpingLaserAtomic and Molecular Physics and Opticslaw.inventionLaser linewidthOpticslawDiode-pumped solid-state laserOptoelectronicsPhysics::Atomic PhysicsLaser power scalingLaser beam qualitybusinessPhysical Review A
researchProduct

Towards high photon-number soft x-ray lasers

2011

We present an experimental design to independently pump two soft X-ray laser media suitable for a seed-amplifier configuration. Both the seed and the amplifier target are operated in the TCE scheme utilizing the DGRIP technique with its intrinsic travelling wave excitation. Controlled injection of the seed X-ray laser into the amplifier medium is realized via a spherical XUV mirror. The experimental design is perfectly appropriate for benchmarking combined simulations of the ARWEN and DeepOne code. A first experiment at the PHELIX laser utilizing this scheme has been conducted, demonstrating signs of amplification and allowing for the direct measurement of the gain life time of a Ni-like si…

PhysicsSoft x rayPhotonbusiness.industryAmplifierPhelixLaserlaw.inventionX-ray laserOpticslawExtreme ultravioletOptoelectronicsbusinessExcitationSPIE Proceedings
researchProduct

LASERIX: an open facility for developments of Soft X-ray and EUV lasers and applications

2011

In this paper we report the perspectives of the development of the XUV laser sources and applications using High-power laser facilities. We focus our paper on the present status of the French LASERIX facility and more especially about its role in the development of the XUV laser sources considering the French "Institut de la Lumiere Extreme " (ILE) and the potential European project Extreme Light Infrastructure (ELI). Finally, we present the scientific perspectives of X-ray laser sources developments using these laser facilities.

PhysicsSoft x rayOpticsOpen facilityExtreme Light Infrastructurebusiness.industrylawExtreme ultraviolet lithographyExtreme ultravioletbusinessLaserlaw.inventionSPIE Proceedings
researchProduct

Stable and long-time operation of a soft x-ray laser for user applications experiments

2011

LASERIX is a high-power laser facility leading to High-repetition-rate XUV laser pumped by Titanium:Sapphire laser. The aim of this laser facility is to offer Soft XRLs in the 30-7 nm range and auxiliary IR beam that could also be used to produce synchronized XUV sources. This experimental configuration highly enhances the scientific opportunities of the facility, giving thus the opportunity to realize both X-ray laser experiments and more generally pump/probe experiments, mixing IR and XUV sources. In this contribution, the main results concerning both the development of XUV sources(X-Ray lasers and HHG sources) and their use for applications are presented.

Range (particle radiation)Soft x rayMaterials sciencebusiness.industryLaserlaw.inventionX-ray laserOpticslawExtreme ultravioletSapphireOptoelectronicsHigh harmonic generationbusinessBeam (structure)SPIE Proceedings
researchProduct

Demonstration of an efficient pumping scheme for a 7.36-nm Ni-like samarium soft x-ray laser

2010

The demonstration of a 7.36 nm Ni-like Sm soft x-ray laser pumped by 36 J of a Nd:glass chirped pulse amplification laser is presented. Double-pulse single-beam non-normal incidence pumping was applied for the efficient soft x-ray laser generation. Here the applied technique included a new single optic focusing geometry for large beam diameters, a single-pass grating compressor traveling-wave tuning capability and an optimized high energy laser double-pulse. This scheme has the potential for even shorter wavelength soft x-ray laser pumping.

Chirped pulse amplificationDistributed feedback laserMaterials scienceActive laser mediumbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaFar-infrared laserPhysics::OpticsLaser pumpingLaserlaw.inventionOpticslawOptoelectronicsPhysics::Atomic PhysicsLaser power scalingLaser beam qualitybusinessSPIE Proceedings
researchProduct

Characterization of a 10Hz double-pulse non-normal incidence pumped transient collisional Ni-like molybdenum soft x-ray laser for applications

2009

Stable and reliable operation of a nickel-like molybdenum transient collisional soft x-ray laser at 18.9 nm demonstrated and studied with a 10Hz Ti:sapphire laser system proves the suitability of the double-pulse non-normal incidence pumping geometry for table-top high repetition soft x-ray lasers and broadens the attractiveness of x-ray lasers as sources of coherent radiation for various applications. X-ray laser emission with pulse energies well above 1 μJ is obtained for several hours at 10Hz repetition-rate without re-alignment under optimized double pumping pulse parameters including energy ratio, time delay, pulse duration and line focus width.

Materials sciencebusiness.industryAstrophysics::High Energy Astrophysical PhenomenaPhysics::OpticsPulse durationRadiationLaserlaw.inventionPulse (physics)X-ray laserOpticslawSapphireTransient (oscillation)businessPulse-width modulationSPIE Proceedings
researchProduct

Gain lifetime measurement of a Ni-like Ag soft X-ray laser

2012

International audience; Experimental results of a two-stage Ni-like Ag soft X-ray laser operated in a seed-amplifier configuration are presented. Both targets were pumped applying the double-pulse grazing incidence technique with intrinsic travelling wave excitation. The injection of the seed X-ray laser into the amplifier target was realized by a spherical mirror. The results show amplification of the seed X-ray laser and allow for a direct measurement of the gain lifetime. The experimental configuration is suitable for providing valuable input for computational simulations. (C) 2012 Optical Society of America

Amplified spontaneous emissionCODEPhysics::OpticsCurved mirrorBEAM01 natural scienceslaw.inventionCOHERENT010309 opticsLaser linewidthOptics[PHYS.PHYS.PHYS-PLASM-PH]Physics [physics]/Physics [physics]/Plasma Physics [physics.plasm-ph]law0103 physical sciencesSpontaneous emission010306 general physicsPhysics[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryAmplifierLaserAtomic and Molecular Physics and OpticsTemporal resolutionOptoelectronicsbusinessExcitationOptics Express
researchProduct

Perspectives of XUV sources development on LASERIX facility, ILE, and ELI

2009

In this paper we present the perspectives of the development of the XUV laser sources using High-power laser facilities. We focus our paper on the present statuts of the LASERIX facility and especially its role in the development of the XUV laser sources considering the French "Institut de la Lumiere Extreme" (ILE) and the potential European project Extreme Light Infrastructure (ELI).

PhysicsOpticsExtreme Light Infrastructurebusiness.industrylawExtreme ultravioletbusinessLaserEngineering physicslaw.inventionSPIE Proceedings
researchProduct