Jan M. Vetter
Identification of the Muscarinic Acetylcholine Receptor Subtype Mediating Cholinergic Vasodilation in Murine Retinal Arterioles
To identify the muscarinic acetylcholine receptor subtype that mediates cholinergic vasodilation in murine retinal arterioles.Muscarinic receptor gene expression was determined in murine retinal arterioles using real-time PCR. To assess the functional relevance of muscarinic receptors for mediating vascular responses, retinal vascular preparations from muscarinic receptor-deficient mice were studied in vitro. Changes in luminal arteriole diameter in response to muscarinic and nonmuscarinic vasoactive substances were measured by video microscopy.Only mRNA for the M(3) receptor was detected in retinal arterioles. Thus, M(3) receptor-deficient mice (M3R(-/-)) and respective wild-type controls …
Pars Plana Vitrectomy for Visually Disturbing Vitreous Floaters in Pseudophacic Eyes
Background The aim of this study was to evaluate the role of vitrectomy in patients with visually disturbing vitreous opacities. Patients and methods A retrospective analysis of the patient characteristics and the outcome of all pseudophacic eyes, which consecutively received in the decade 1996 to 2005 20 G pars plana vitrectomy for visually disturbing floaters, was carried out at the Mainz University Eye Clinic. Results Forty-one eyes of 32 patients (63 % university graduates, median age: 64 years) were included in the study. The mean axial length of the globe was 25.3 mm (range: 22.8 to 28.9 mm). Additional pathologies having influence on the vitreous condition were history of laser or cr…
Langzeitverlauf 10 Jahre nach transpupillarer Thermotherapie (TTT) kleiner, posteriorer maligner Aderhautmelanome
Background The aim of this study was to evaluate the long-term results of transpupillary thermotherapy (TTT) for small malignant choroidal melanomas. Patients and methods In the time period 1/1998 to 10/1999 in a prospective non-randomised analysis 26 eyes with small malignant melanomas (located posterior to the equator with base ≤ 12 and thickness ≤ 4.5 mm) were primary treated with the TTT standard protocol (follow-up over a time span of at least 10 years). Results Thirteen women and thirteen men (mean age: 64 years) underwent TTT. The mean preoperative tumour thickness was 2.45 mm (0.8 - 4.5 mm). Ten years postoperatively tumour regression without recurrence after 1.4 treatment sessions …
Intraocular pressure measurements during flap preparation using 2 femtosecond lasers and 1 microkeratome in human donor eyes
Purpose To evaluate and compare intraocular pressures (IOPs) during flap preparations performed using 2 femtosecond lasers and a mechanical microkeratome in human donor globes. Setting University Medical Center Mainz, Mainz, and Euroeyes Clinic Stuttgart, Stuttgart, Germany. Design Experimental study. Methods A cannula was inserted through the optic nerve in human globes. The IOP was obtained continuously during flap preparation using the 60 kHz Intralase femtosecond laser, the 200 kHz Visumax femtosecond laser, or the Amadeus II microkeratome. For each experiment, a normal lamellar flap preparation (regular procedure) and a worst-case procedure (femtosecond laser interface was pressed agai…
Expression and subcellular localization of USH1C/harmonin in the human retina provide insights into pathomechanisms and therapy
AbstractUsher syndrome (USH) is the most common form of hereditary deafness-blindness in humans. USH is a complex genetic disorder, assigned to three clinical subtypes differing in onset, course, and severity, with USH1 being the most severe. Rodent USH1 models do not reflect the ocular phenotype observed in human patients to date; hence, little is known about the pathophysiology of USH1 in the human eye. One of the USH1 genes, USH1C, exhibits extensive alternative splicing and encodes numerous harmonin protein isoforms that function as scaffolds for organizing the USH interactome. RNA-seq analysis of human retinas uncovered harmonin_a1 as the most abundant transcript of USH1C. Bulk RNA-seq…
Surgical management of acute angle-closure glaucoma after toric implantable contact lens implantation
A case of pupillary block after implantation of an implantable contact lens (ICL) is reported, and surgical management and prevention are discussed. In a myopic patient, the best corrected visual acuity in the right eye was 20/50 with -15.50 -3.00 x 175. After uneventful implantation of an ICL, painful acute glaucoma developed with an intraocular pressure beyond measurable values. Apparent anterior vaulting of the ICL suggested a sizing problem. In a situation of a mid-wide dilated pupil, immediate explantation of the ICL was performed. Then, using a preoperative iris photography as guidance, an anterior chamber iris-claw toric phakic intraocular lens was implanted. On postoperative examina…
Irregularity of the posterior corneal surface after curved interface femtosecond laser-assisted versus microkeratome-assisted descemet stripping automated endothelial keratoplasty.
During donor tissue preparation for Descemet stripping automated endothelial keratoplasty (DSAEK), either microkeratome or femtosecond laser can be used for intrastromal cutting. We compared morphological and functional outcomes after DSAEK using both cutting techniques.In this retrospective study, 22 uneventful DSAEK surgeries were reviewed. Eight donor corneas were prepared for DSAEK using the VisuMax femtosecond laser (Carl Zeiss Meditec AG, Jena, Germany). Fourteen corneas were processed using an Amadeus II microkeratome (Ziemer Ophthalmic Systems AG, Port, Switzerland). The postoperative best spectacle-corrected visual acuity was measured. Furthermore, corneal optical coherence tomogra…
Functional Role of α1-Adrenoceptor Subtypes in Murine Ophthalmic Arteries
PURPOSE To identify the α(1)-adrenoceptor (α(1)-AR) subtypes mediating vascular adrenergic responses in murine ophthalmic arteries. METHODS Expression of mRNA was quantified for individual α(1)-AR subtypes in murine ophthalmic arteries using real-time PCR. To assess the functional relevance of α(1)-ARs for mediating vascular responses, ophthalmic arteries from mice deficient in one of the three α(1)-AR subtypes (α(1A)-AR(-/-), α(1B)-AR(-/-), and α(1D)-AR(-/-), respectively) and wild-type controls were isolated, cannulated with micropipettes, and pressurized. Changes in luminal artery diameter in response to the α(1)-AR agonist phenylephrine, the sympathetic transmitter noradrenaline, and to…
Survival After Transplantation of Corneas From a Rabies-Infected Donor
To examine the tissue samples of 2 corneal recipients from a rabies-infected donor for the presence of rabies to explain their survival.Interventional case series with a review of the literature. The explanted corneal donor buttons were examined via nested reverse transcriptase polymerase chain reaction. The patients were followed up ophthalmologically and neurologically. Antirabies antibodies were measured in blood samples, and skin biopsies were examined by direct fluorescent antibody staining.Two patients received corneas from the same multiorgan donor. Six weeks after transplantation, 3 of the donor's organ recipients became symptomatic and rabies virus was confirmed in tissue from the …
Entwicklung der Hornhautdicke während der UV-Vernetzungstherapie unter Anwendung verschiedener Kompositionen von Riboflavin-Augentropfen
Background During the UVA-cross-linking treatment in keratoconus patients, the UVA rays are partially absorbed in the stroma of the riboflavin-loaded cornea. This effect protects the corneal endothelium from UVA irradiation damage. The intensity of UVA light reaching the endothelium is inversely correlated with corneal thickness. The common composition of riboflavin eye drops may lead to a marked reduction in corneal thickness increasing the risk of endothelial damage. Patients and methods In a retrospective analysis of 23 UVA-cross-linking procedures on 23 patients we collected data about the pre-, intra- and postoperative corneal thickness (measured with ultrasound). Among these patients …
The Effect of Long-Term Storage on the Biological and Histological Properties of Cryopreserved Amniotic Membrane
Cryopreserved amniotic membrane (AM) is widely used in ophthalmology because of its anti-angiogenic, anti-inflammatory, and wound healing promoting capabilities. A common method to conserve the tissue is the storage in cryo-medium containing 50% glycerol at -80°C. The aim of this study was to examine the influence of storage time on the sterility as well as the histological and biological properties of cryopreserved AM.Amniotic membrane from different donors was stored in cell culture media containing 50% glycerol for different time periods, on average 4 months (group 1), 15 months (group 2), and 24 months (group 3), at -80°C. Samples of the tissue and cryo-medium were examined for bacteria…
Irregularity of the posterior corneal surface during applanation using a curved femtosecond laser interface and microkeratome cutting head.
PURPOSE: To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome. METHODS: Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography…
Series of fibrinous inflammation after implantation of capsular tension rings
Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…
Modulation of central corneal thickness by various riboflavin eyedrop compositions in porcine corneas
Purpose To evaluate the modulatory effect of various riboflavin 0.1% and 0.2% compositions on the central corneal thickness (CCT) in fresh porcine corneas. Setting Department of Ophthalmology, Johannes Gutenberg University of Mainz, Mainz, Germany. Design Experimental study. Methods The CCT in freshly enucleated porcine globes was measured by ultrasound pachymetry before and after (if applicable) deepithelialization and every 10 minutes thereafter during 120 minutes of eyedrop application. In Groups 1 and 2 (controls), no eyedrops were applied. In Groups 3 and 4, isotonic riboflavin eyedrops were used. In Groups 5 to 9, hypotonic riboflavin eyedrops were given. In Groups 10 and 11, preparat…
Comparison of Intraocular Pressure During Corneal Flap Preparation Between a Femtosecond Laser and a Mechanical Microkeratome in Porcine Eyes
To compare the increase in intraocular pressure (IOP) during corneal flap preparation in porcine eyes when using a femtosecond laser or a mechanical microkeratome.The present study was conducted at a university hospital and a private clinic.The vitreous IOP was directly measured with a cannula through the optic nerve in 24 porcine globes (n = 12 for each device). In the first procedure (worst-case procedure), the eye interface was lowered against the globe until abortion of the docking maneuver when using the IntraLase femtosecond laser (Abbott Medical Optics, Santa Ana, CA) or the suction ring was pressed very firmly against the globe when using the Amadeus microkeratome (Ziemer Ophthalmic…
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…