0000000000009072

AUTHOR

Giuseppina Sallustio

showing 2 related works from this author

Preferential patterns of myocardial iron overload by multislice multiecho T2* CMR in thalassemia major patients.

2010

T*(2) multislice multiecho cardiac MR allows quantification of the segmental distribution of myocardial iron overload. This study aimed to determine if there were preferential patterns of myocardial iron overload in thalassemia major. Five hundred twenty-three thalassemia major patients underwent cardiac MR. Three short-axis views of the left ventricle were acquired and analyzed using a 16-segment standardized model. The T*(2) value on each segment was calculated, as well as the global value. Four main circumferential regions (anterior, septal, inferior, and lateral) were defined. Significant segmental variability was found in the 229 patients with significant myocardial iron overload (glob…

AdultMalepreferential patternIron OverloadAdolescentmyocardial iron overloadThalassemiamultislice multiecho T*2Myocardial ironcardiovascular magnetic resonanceBasal (phylogenetics)HumansMedicineRadiology Nuclear Medicine and imagingMultisliceChelation therapyChildHemochromatosisRetrospective Studiesmedicine.diagnostic_testbusiness.industryMyocardiumbeta-ThalassemiaHeartMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingRadiographymedicine.anatomical_structureVentriclethalassemia majorFemalebusinessNuclear medicine
researchProduct

Multicenter validation of the magnetic resonance t2* technique for segmental and global quantification of myocardial iron

2009

Purpose To assess the transferability of the magnetic resonance imaging (MRI) multislice multiecho T2* technique for global and segmental measurement of iron overload in thalassemia patients. Materials and Methods Multiecho T2* sequences were installed on six MRI scanners. Five healthy subjects (n = 30) were scanned at each site; five thalassemia major (TM) patients were scanned at the reference site and were rescanned locally (n = 25) within 1 month. T2* images were analyzed using previously validated software. Results T2* values of healthy subjects showed intersite homogeneity. On TM patients, for global heart T2* values the correlation coefficient was 0.97, coefficients of variation (CoV…

Adultmyocardial iron; T2* techniqueCorrelation coefficientHeart VentriclesIronReference siteTransferabilityMyocardial ironReference ValuesImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingMultislicemyocardial ironAnalysis of VarianceReproducibilitymedicine.diagnostic_testbusiness.industryMyocardiumHealthy subjectsT2* techniqueReproducibility of ResultsMagnetic resonance imagingMagnetic Resonance ImagingItalyLiverThalassemiabusinessNuclear medicineJournal of Magnetic Resonance Imaging
researchProduct