0000000000011209
AUTHOR
Gheorghe Pascovici
Position resolution of the prototype AGATA triple-cluster detector from an in-beam experiment
AGATA belongs to a new generation of gamma-ray detector arrays for nuclear spectroscopy at present in its final stage of development. The detectors of these new arrays will be based on 36-fold electronically segmented coaxial germanium diodes operated in position sensitive mode. An in-beam test of the AGATA prototype triple cluster detector was carried out with the purpose of demonstrating the feasibility of such detectors and in order to measure the most sensitive parameters for their overall performance. An inverse kinematics reaction was performed, using a (48)Ti beam at an energy of 100MeV, impinging on a deuterated titanium tat-get. The results from the analysis of the experimental dat…
Development of a new Recoil Distance Technique using Coulomb Excitation in Inverse Kinematics
We report on an experiment using Coulomb excitation in inverse kinematics in combination with the plunger technique for measuring lifetimes of excited states of the projectiles. Aside from the investigation of E(5) features in 128Xe, the aim was to explore the special features of such experiments which are also suited to be used with radioactive beams. The measurement was performed at the JYFL with the Koln coincidence plunger device and the JUROGAM spectrometer using a 128Xe beam impinging on a natFe target at a beam energy of 525 MeV. Recoils were detected by means of 32 solar cells placed at extreme forward angles. Particle‐gated γ‐singles and γγ‐coincidences were measured at different t…
A new recoil distance technique using low energy coulomb excitation in inverse kinematics
Abstract We report on the first experiment combining the Recoil Distance Doppler Shift technique and multistep Coulomb excitation in inverse kinematics at beam energies of 3–10 A MeV. The setup involves a standard plunger device equipped with a degrader foil instead of the normally used stopper foil. An array of particle detectors is positioned at forward angles to detect target-like recoil nuclei which are used as a trigger to discriminate against excitations in the degrader foil. The method has been successfully applied to measure lifetimes in 128Xe and is suited to be a useful tool for experiments with radioactive ion beams.
Conceptual design and infrastructure for the installation of the first AGATA sub-array at LNL
WOS: 000295765100014
The Miniball spectrometer
The Miniball germanium detector array has been operational at the REX (Radioactive ion beam EXperiment) post accelerator at the Isotope Separator On-Line facility ISOLDE at CERN since 2001. During the last decade, a series of successful Coulomb excitation and transfer reaction studies have been performed with this array, utilizing the unique and high-quality radioactive ion beams which are available at ISOLDE. In this article, an overview is given of the technical details of the full Miniball setup, including a description of the γ-ray and particle detectors, beam monitoring devices and methods to deal with beam contamination. The specific timing properties of the REX-ISOLDE facility are hi…
Coulomb Excitation ofCu68,70: First Use of Postaccelerated Isomeric Beams
We report on the first low-energy Coulomb excitation measurements with radioactive Ipi=6- beams of odd-odd nuclei 68,70Cu. The beams were produced at ISOLDE, CERN and were post-accelerated by REX-ISOLDE to 2.83 MeV/nucleon. gamma rays were detected with the MINIBALL spectrometer. The 6- beam was used to study the multiplet of states (3-, 4-, 5-, 6-) arising from the pi2p3/2nu1g9/2 configuration. The 4- state of the multiplet was populated via Coulomb excitation and the B(E2;6--->4-) value was determined in both nuclei. The results obtained illustrate the fragile stability of the Z=28 shell and N=40 subshell closures. A comparison with large-scale shell-model calculations using the 56Ni core…
Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors
WOS: 000290082600015
AGATA-Advanced GAmma Tracking Array
WOS: 000300864200005