0000000000014653

AUTHOR

Carlos Labaig-rueda

showing 17 related works from this author

Implant treatment in patients with osteoporosis

2010

Osteoporosis is very common, particularly in post-menopausal women and is characterized by a decrease in bone mass and strength. Osteoporosis also affects the jawbone and it is considered a potential contraindication to placement of dental implants. The present paper reviews the literature regarding the effect of osteoporosis on osseointegration of implants. Experimental models have shown that osteoporosis affects the process of osseointegration, which can be reversed by treatment. However, studies in subjects with osteoporosis have shown no differences in survival of the implants compared to healthy individuals. Therefore, osteoporosis cannot be considered a contraindication for implant pl…

medicine.medical_specialtyOsteoporosisDentistryOsseointegrationOsseointegrationInformed consentHumansMedicineIn patientGeneral DentistryContraindicationDental ImplantsDiphosphonatesbusiness.industrymedicine.disease:CIENCIAS MÉDICAS [UNESCO]SurgeryOtorhinolaryngologyPractice Guidelines as TopicUNESCO::CIENCIAS MÉDICASOsteoporosisSurgeryImplantbusinessOsteonecrosis of the jawComplicationJaw Diseases
researchProduct

Clinical Behavior of Short Dental Implants: Systematic Review and Meta-Analysis

2020

Short implants are an increasingly common alternative to other surgical techniques in areas where bone availability is reduced. Despite the advantages they offer, a variety of biological repercussions have been described in the literature that can even lead to the loss of these. The aim of this systematic review and meta-analysis was to analyze the impact of the use of short implants on their survival and on peri-implant bone loss, evaluating the influence that length, diameter, and crown-to-implant ratio (C/I) have on these parameters. This systematic review was based on guidelines proposed by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). An electronic se…

survival rateWeb of scienceDentistrylcsh:MedicineReview03 medical and health sciences0302 clinical medicineQualitative analysis0502 economics and businessMedicineLead (electronics)Survival ratebusiness.industry05 social scienceslcsh:R030206 dentistryGeneral Medicineedentulous mouthShort implantsSystematic reviewMeta-analysiscrown-to-implant ratio050211 marketingImplantpartially edentulous mouthshort implantsbusinessJournal of Clinical Medicine
researchProduct

Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Pa…

2019

Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years of functional loading. Materials and methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (group GS); cemented crown without finishing line (biologically oriented preparation technique) (group GBOPT); and conventional cemented crown with finishing line (group GCC). After three years in function, clinical parameters (presence of keratinized mucosa, probing depths, bleeding on probing, and radio…

complicationsmedicine.medical_treatmentRadiographyBleeding on probingPeriDentistryProsthesisCrown (dentistry)Articlelaw.invention03 medical and health sciencesimplant-supported prosthesis0302 clinical medicineRandomized controlled triallaw0502 economics and businessmedicinebusiness.industry05 social sciencesSoft tissue030206 dentistryGeneral MedicineBOPTscrew-retainedbone loss and clinical parameterscemented050211 marketingImplantmedicine.symptombusinesssoft tissuesJournal of Clinical Medicine
researchProduct

Post-fatigue fracture resistance of metal core crowns: press-on metal ceramic versus a conventional veneering system

2014

Background The aim of this in vitro study was to compare the mechanical failure behavior and to analyze fracture characteristics of metal ceramic crowns with two veneering systems – press-on metal (PoM) ceramic versus a conventional veneering system – subjected to static compressive loading. Material and Methods Forty-six crowns were constructed and divided into two groups according to porcelain veneer manufacture. Group A: 23 metal copings with porcelain IPS-InLine veneering (conventional metal ceramic). Group B: 23 metal copings with IPS-InLine PoM veneering porcelain. After 120,000 fatigue cycles, the crowns were axially loaded to the moment of fracture with a universal testing machine. …

Prosthetic DentistryUniversal testing machineMaterials scienceScanning electron microscopeResearchmedicine.medical_treatmentPorcelain VeneerOdontologíaCore (manufacturing):CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludvisual_artUNESCO::CIENCIAS MÉDICASmedicinevisual_art.visual_art_mediumFracture (geology)VeneerCeramicAdhesiveComposite materialGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

In vitro preliminary study of osteoblast response to surface roughness of titanium discs and topical application of melatonin

2014

Objectives: To observe human osteoblast behavior cultured in vitro on titanium discs (Ti) in relation to surface roughness and melatonin application. Study Design: Human osteoblasts (MG-63) were cultured on 60 Ti6Al4V discs divided into three groups: Group I: discs treated with dual acid etching; Group II dual acid etching and blasting with calcium phosphate particles; Group III (control) machined discs. Surface roughness and topography of the discs were examined with scanning electron microscope (SEM) and confocal laser scanning electron microscope( CLSM). Osteoblast adhesion, proliferation and cell morphology were determined by means of fluorescence microscopy with Image-Pro Plus software…

Materials scienceScanning electron microscopeSurface PropertiesAdministration Topicalchemistry.chemical_elementDentistryOdontologíaCell morphologylaw.inventionlawFluorescence microscopemedicineSurface roughnessHumansCell adhesionGeneral DentistryCells CulturedMelatoninDental ImplantsTitaniumOsteoblastsbusiness.industryResearchOsteoblast:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludmedicine.anatomical_structureOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASSurgeryElectron microscopebusinessImplantologyTitaniumBiomedical engineering
researchProduct

Behavior of Human Osteoblast Cells Cultured on Titanium Discs in Relation to Surface Roughness and Presence of Melatonin

2017

The aim of this work was to observe the behavior of osteoblast cells cultured in vitro on titanium discs in relation to disc surface roughness and the addition of melatonin to the culture medium. MG63 osteoblast cells were cultivated on 120 Grade 5 Ti divided into three groups: Group E, treated with dual acid etch; Group EP, treated with dual acid etch and calcium phosphate; and Group M, machined. Surface roughness was examined under a laser scanning confocal microscope (CLSM) and scanning electron microscopy (SEM). The proliferation and morphology of cells were determined under fluorescence microscopy and SEM. Messenger ribonucleic acid (mRNA) of different genes related to osteoblastic dif…

PHEXSurface PropertiesproliferationmRNAConfocalchemistry.chemical_elementmelatoninosteoblasts; titanium; roughness; melatonin; proliferation; differentiation; mRNA; PHEX; dental implantsCalciumArticleCatalysisOsseointegrationCell LineInorganic ChemistryMelatonin03 medical and health sciences0302 clinical medicinedental implantsCell AdhesionmedicineFluorescence microscopeHumansRNA MessengerPhysical and Theoretical ChemistryMolecular BiologySpectroscopyCell ProliferationroughnessTitaniumMicroscopy ConfocalOsteoblastsCell growthOrganic ChemistryCell DifferentiationOsteoblastdifferentiation030206 dentistryGeneral MedicineAnatomyMolecular biologyIn vitroComputer Science Applicationsmedicine.anatomical_structurechemistryMicroscopy Electron Scanning030217 neurology & neurosurgerymedicine.drugInternational Journal of Molecular Sciences
researchProduct

Biologically oriented preparation technique (BOPT) for implant-supported fixed prostheses

2017

A patient of 58 years of age without medical problems came to the clinic due to missing teeth in the upper posterior region and to change the partial fixed prosthesis in the upper anterior area. Proposed treatment: surgical phase of three conical shape tapering implants with prosthetic platform in occlusal direction with mechanize collar tissue level with fixtures to place implant-supported metal-ceramic restorations. In the anterior area, a zirconium oxide fixed partial prosthesis was vertical preparation of the tooth’s. When preparing teeth to receive fixed prostheses, the definition and shape of finish lines has been a subject of endless discussion, modification, and change ever since th…

Prosthetic DentistryFixed prosthesisbusiness.industryComputer sciencemedicine.medical_treatment05 social sciencesDentistryTissue levelCase ReportContext (language use)030206 dentistryFinish line:CIENCIAS MÉDICAS [UNESCO]Prosthesis03 medical and health sciences0302 clinical medicineUpper anterior0502 economics and businessUNESCO::CIENCIAS MÉDICASmedicineZirconium oxide050211 marketingbusinessGeneral DentistryImplant supported
researchProduct

Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.

2018

Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…

Ceramicsmedicine.medical_treatmentDentistryDental AbutmentsCrown (dentistry)Osseointegration03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental AbutmentsmedicineCeramicDental Restoration FailureProspective StudiesSurvival rateDental ImplantsCrownsbusiness.industryDental prosthesis030206 dentistryDental PorcelainMetalsvisual_artvisual_art.visual_art_mediumImplantDental Prosthesis Implant-SupportedZirconiumOral SurgerybusinessThe Journal of prosthetic dentistry
researchProduct

Comparative Analysis of Peri-Implant Bone Loss in Extra-Short, Short, and Conventional Implants. A 3-Year Retrospective Study

2020

Objective: To evaluate the influence of implant length on marginal bone loss, comparing implants of 4 mm, 6 mm, and &gt

MaleMolarmarginal bone lossPeri-implantitisHealth Toxicology and MutagenesisRadiographyAlveolar Bone LossDentistrylcsh:MedicinePeri implant boneArticleMandibular second molar03 medical and health sciences0302 clinical medicineimplant-supported prosthesesshort dental implantsHumansMedicineDental Restoration FailureRetrospective StudiesDental Implantstissue-levelCrownsbusiness.industryPeriapical radiographylcsh:RPublic Health Environmental and Occupational HealthRetrospective cohort study030206 dentistryMolarTreatment Outcome030220 oncology & carcinogenesisFemaleImplantbusinessFollow-Up Studiesperi-implantitisInternational Journal of Environmental Research and Public Health
researchProduct

A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.

2014

Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…

Dental Restoration FailureAdultMaleSurface Propertiesmedicine.medical_treatmentDentistryDental CariesProsthesisProspective evaluationAnterior regionDental MaterialsRecurrencemedicineHumansDental Restoration FailureProspective StudiesProspective cohort studyDenture DesignSurvival rateAgedbusiness.industryPeriapical DiseasesMiddle AgedDental PorcelainDenture RetentionSurvival AnalysisDental VeneersTreatment OutcomeComputer-Aided DesignDenture Partial FixedVeneerFemaleZirconiumOral SurgerybusinessComplicationFollow-Up StudiesThe Journal of prosthetic dentistry
researchProduct

Effect of two whitening agents on the color of composite dental restorations

2018

Background To evaluate color changes to composite resins used to restore extracted teeth compared with composite discs after whitening with two agents: hydrogen peroxide (HP) and carbamide peroxide (CP). Material and methods Ten human molars with class V vestibular and palatine cavity preparation obturated with Vita hybrid nanocomposite were hemisected to obtain 20 specimens assigned randomly to two groups: O1 and O2. Twenty composite discs were divided into two groups: D1 and D2. The groups O1 and D1 were treated with 16% CP, while groups =2 and D2 were treated with 37.5 % HP. Chromaticity coordinates L*, a* and b* were registered using a spectrophotometer. Results Statistically significan…

MolarChemistrybusiness.industryResearchComposite numberDentistryEsthetic Dentistry030206 dentistry:CIENCIAS MÉDICAS [UNESCO]03 medical and health scienceschemistry.chemical_compound0302 clinical medicineColor changesUNESCO::CIENCIAS MÉDICASIn vitro study030212 general & internal medicineChromaticityCarbamide peroxidebusinessHydrogen peroxideGeneral DentistryWhitening AgentsJournal of Clinical and Experimental Dentistry
researchProduct

Analysis of Predisposing Factors for Rapid Dental Calculus Formation.

2020

Background: Calculus accumulation varies widely between individuals. Dental calculus has been associated with the principal periodontal diseases. The aim of this study was to analyze individual characteristics, and salivary and microbiological parameters among patients considered to be rapid calculus formers and patients who form calculus slowly. Methods: Individual characteristics were recorded in a sample of 74 patients (age, sex, smoking, periodontal diagnosis, and dental crowding), as well as salivary parameters (unstimulated saliva flow, pH, and biochemical analysis of saliva) and microbiological parameters (by means of semi-quantitative polymerase chain reaction (PCR) analysis). Resul…

Salivaeducationlcsh:MedicineArticle03 medical and health sciences0302 clinical medicineoral bacteriaPeriodontal diseasemedicineCalculusheavy calculus formers030304 developmental biology0303 health sciencesbiologybusiness.industryCalculus (dental)lcsh:Rdental calculus030206 dentistryGeneral Medicinemedicine.diseasebiology.organism_classificationStreptococcus mutansDental crowdingstomatognathic diseasesbusinessJournal of clinical medicine
researchProduct

Clinical outcomes of veneered zirconia anterior partial fixed dental prostheses: A 12-year prospective clinical trial

2019

Abstract Statement of problem Anterior veneered zirconia partial fixed dental prostheses (FDPs) have substituted for metal-ceramic to improve esthetics and biocompatibility. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Whether these susceptibilities limit the clinical performance of anterior veneered zirconia FPDs is unclear. Purpose The purpose of this prospective clinical study was to analyze the mechanical and biologic behavior of zirconia partial FDPs in the anterior region over a 12-year follow-up period. Material and methods Twenty-seven 3- to 6-unit FDPs fabricated from zirconia veneered with feldspathic porcelai…

Periapical pathologyDentistryDental CariesEsthetics DentalAnterior regionDental Materials03 medical and health sciences0302 clinical medicinePeriodontal diseaseHumansMedicineDental Restoration FailureProspective StudiesSurvival rateBiological Productsbusiness.industryDental prosthesisClinical performance030206 dentistryDental PorcelainClinical trialDental VeneersDenture Partial FixedZirconiumOral SurgeryComplicationbusinessThe Journal of Prosthetic Dentistry
researchProduct

A clinical longitudinal study 323 porcelain laminate veneers. Period of study from 3 to 11 years

2009

Objective: The objective of this study was to evaluate the clinical results of 323 porcelain laminate veneers over a period of 3 to 11 years. Material and Methods: This study included 70 patients, aged between 18 and 74 years. Of the 323 total veneers, 124 were of a simple design and 199 were of a functional design. The condition of the soft tissues and hygiene, in addition to the condition of the abutment teeth, the restorations and patient satisfaction were all clinically examined. In carrying out the statistical analysis, a descriptive approach was taken in analyzing the data. The Kaplan Meier method was used for statistically analyzing the survival rates of the porcelain laminate veneer…

AdultMaleLongitudinal studyTime FactorsAdolescentDentistryYoung AdultPatient satisfactionTooth pulp stimulationHumansMedicineStatistical analysisLongitudinal StudiesGeneral DentistryAgedbusiness.industryTreatment optionsSoft tissueMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Dental PorcelainDental VeneersOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASFemaleSurgerybusinessAbutment (dentistry)Medicina Oral Patología Oral y Cirugia Bucal
researchProduct

Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material ver…

2019

Background The aim of this study was to compare a conventional technique (elastomeric impression material - EIM) and a digital technique (scanner digital model – SDM) on a six-analog master model (MM) to determine which was the most exact. Material and Methods Twenty impressions were taken of a master model (EIM) and twenty scanned impressions (SDM) (True Definition). A coordinate measuring machine (CMM) was used to measure the distances between adjacent analogues (1-2, 2-3, 3-4, 4-5, 5-6), intermittently positioned analogues (1-4, 3-6) and the most distal (1-6). Reference values were established from the master model, which were compared with the two impression techniques. The significance…

ScannerDental Impression TechniqueIn Vitro TechniquesCoordinate-measuring machine03 medical and health sciences0302 clinical medicineIn vitro study030212 general & internal medicineGeneral DentistryMathematicsConventional techniqueDental ImplantsIntraoral scannerResearchDental Impression Materials030206 dentistryDirect Technique:CIENCIAS MÉDICAS [UNESCO]Models DentalImpressionOtorhinolaryngologyElastomersDimensional Measurement AccuracyReference valuesUNESCO::CIENCIAS MÉDICASComputer-Aided DesignSurgeryOral SurgeryBiomedical engineeringMedicina oral, patologia oral y cirugia bucal
researchProduct

An implant-supported overdenture design with a horizontal path of insertion

2013

The rehabilitation of the atrophic maxilla by means of implant-supported prostheses cannot always be achieved with fixed prostheses because of anatomic, esthetic, or economic issues, so for some patients the treatment of choice is a removable prosthesis. This article analyzes a new design for implant-supported overdentures with horizontal or faciolingual insertion. Its retention system is based on frictional forces or stepped interlocking horizontal surfaces and is appropriate for patients with skeletal Class II or III relationships with severe maxillary atrophies. The design facilitates implant-prosthetic hygiene and improved esthetics in patients with nonparallel implants by hiding abutme…

EngineeringFrictionDentistryEsthetics DentalMalocclusion Angle Class IIMaxillaAtrophic maxillaHumansIn patientDenture DesignInterlockingbusiness.industryDenture Complete UpperDental Implant-Abutment DesignDenture OverlayOral HygieneSkeletal classDenture RetentionMalocclusion Angle Class IIIRemovable prosthesisDental Prosthesis Implant-SupportedAtrophyOral SurgerybusinessAbutment (dentistry)Implant supportedThe Journal of Prosthetic Dentistry
researchProduct

Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Pati…

2020

Background and objectives: To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator&reg

MaleMedicine (General)Dental WearDentistryoverdentureODB++ArticlebarCohort StudiesDental Prosthesis Retentionlocator03 medical and health sciencesR5-9200302 clinical medicinePatient satisfactionSurveys and QuestionnairesmedicineHumansDental Restoration FailureProspective StudiesProspective cohort studyAgedMechanical PhenomenaDental ImplantsEdentulismbusiness.industry030206 dentistrymedicine.diseaseDenture Overlayclinical outcomesTreatment OutcomeScrew looseningPatient SatisfactionAutomotive Engineeringdental implants; overdenture; locator; bar; clinical outcomesFemaleDental Prosthesis Implant-SupportedMouth Edentulousbusiness030217 neurology & neurosurgeryImplant supportedCohort studyFollow-Up StudiesMedicina (Kaunas, Lithuania)
researchProduct