0000000000015287
AUTHOR
V. Toivanen
Periodic Beam Current Oscillations Driven by Electron Cyclotron Instabilities in ECRIS Plasmas
Experimental observation of cyclotron instabilities in electron cyclotron resonance ion source plasma operated in cwmode is reported. The instabilities are associated with strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents. The instabilities are shown to restrict the parameter space available for the optimization of high charge state ion currents. nonPeerReviewed
Experimental evidence on photo-assisted O$^-$ ion production from Al$_2$O$_3$ cathode in cesium sputter negative ion source
The production of negative ions in cesium sputter ion sources is generally considered to be a pure surface process. It has been recently proposed that ion pair production could explain the higher-than-expected beam currents extracted from these ion sources, therefore opening the door for laser-assisted enhancement of the negative ion yield. We have tested this hypothesis by measuring the effect of various pulsed diode lasers on the O$^-$ beam current produced from Al$_2$O$_3$ cathode of a cesium sputter ion source. It is expected that the ion pair production of O$^-$ requires populating the 5d electronic states of neutral cesium, thus implying that the process should be provoked only with s…
Diagnostic techniques of minimum-B ECR ion source plasma instabilities.
The performance of a minimum-B Electron Cyclotron Resonance Ion Source (ECRIS) is traditionally quantified by measuring the beam current and quality of the extracted ion beams of different charge state ions. The stability of the extracted ion beam currents has drawn more attention recently as the technology is pushing its limits toward higher ion charge states and beam intensities. The stability of the extracted beam is often compromised by plasma instabilities manifesting themselves as rapid oscillations of the beam currents in millisecond scale. This paper focuses on practical aspects of diagnostics techniques of the instabilities, showcases examples of instability-related diagnostics sig…
Influence of axial mirror ratios on the kinetic instability threshold in electron cyclotron resonance ion source plasma
International audience; Electron Cyclotron Resonance (ECR) ion source plasmas are prone to kinetic instabilities. The onset of the instabilities manifests as emission of microwaves, bursts of electrons expelled from the plasma volume, and the collapse of the extracted highly charged ion (HCI) currents. Consequently, the instabilities limit the HCI performance of ECR ion sources by limiting the parameter space available for ion source optimization. Previous studies have shown that the transition from stable to unstable plasma regime is strongly influenced by the magnetic field structure, especially the minimum field value inside the magnetic trap (Bmin). This work focuses to study the role o…
The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source.
The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the ca…
Beam current oscillations driven by cyclotron instabilities in a minimum-Belectron cyclotron resonance ion source plasma
Experimental observation of cyclotron instabilities in a minimum-B confined electron cyclotron resonance ion source plasma is reported. The instabilities are associated with strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic ms-scale oscillation of the extracted beam currents. Such non-linear effects are detrimental for the confinement of highly charged ions due to plasma perturbations at shorter periodic intervals in comparison with their production time. It is shown that the repetition rate of the periodic instabilities in oxygen plasmas increases with increasing magnetic field strength and microwave power and decreases with increasi…
Limitation of the ECRIS performance by kinetic plasma instabilities (invited).
Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by …
Quasi-periodical kinetic instabilities in minimum-B confined plasma
We present the results of an experimental investigation of quasi-periodical kinetic instabilities exhibited by magnetically confined electron cyclotron resonance heated plasmas. The instabilities were detected by measuring plasma microwave emission, electron losses, and wall bremsstrahlung. The instabilities were found to be grouped into fast sequences of periodic plasma losses, separated by ∼100 µs between the bursts, followed by 1–10 ms quiescent periods before the next event. Increasing the plasma energy content by adjusting the plasma heating parameters, in particular the magnetic field strength, makes the instabilities more chaotic in the time domain. Statistical analysis reveals that …
Method for estimating charge breeder ECR ion source plasma parameters with short pulse 1+ injection
A new method for determining plasma parameters from beam current transients resulting from short pulse 1+ injection into a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS) has been developed. The proposed method relies on few assumptions, and yields the ionisation times $1/n_e\left\langle\sigma v\right\rangle^{\text{inz}}_{q\to q+1}$, charge exchange times $1/n_0\left\langle\sigma v\right\rangle^{\text{cx}}_{q\to q-1}$, the ion confinement times $\tau^q$, as well as the plasma energy contents $n_e\left\langle E_e\right\rangle$ and the plasma triple products $n_e \left\langle E_e\right\rangle \tau^q$. The method is based on fitting the current balance equation on the extract…
The role of rf-scattering in high-energy electron losses from minimum-B ECR ion source
The measurement of the axially lost electron energy distribution escaping from a minimum-B electron cyclotron resonance ion source in the range of 4-800 keV is reported. The experiments have revealed the existence of a hump at 150-300 keV energy, containing up to 15% of the lost electrons and carrying up to 30% of the measured energy losses. The mean energy of the hump is independent of the microwave power, frequency and neutral gas pressure but increases with the magnetic field strength, most importantly with the value of the minimum-B field. Experiments in pulsed operation mode have indicated the presence of the hump only when microwave power is applied, confirming that the origin of the …
A study of VUV emission and the extracted electron-ion ratio in hydrogen and deuterium plasmas of a filament-driven H−/D− ion source
Vacuum ultraviolet (VUV) emission diagnostics for studying differences of electron impact processes in hydrogen and deuterium plasmas are presented. The method is applied to study a filament driven multicusp arc discharge negative ion source by comparing the VUV-emission intensities of different emission bands and extracted currents of H−/D− ions and electrons. It was found that the ratio of coextracted electrons to extracted ions is four times higher for deuterium than for hydrogen. No significant differences of the VUV-spectra or volumetric rates of ionization, excitation, production of high vibrational states, and dissociation were found between the plasmas of the two isotopes. The volum…
Diagnostics of highly charged plasmas with multicomponent 1+ ion injection
We establish multicomponent 1+ injection into a charge breeder electron cyclotron resonance ion source and an associated computational procedure as a noninvasive probe of the electron density ne, average electron energy ⟨Ee⟩, and the characteristic times of ionization, charge exchange, and ion confinement of stochastically heated, highly charged plasma. Multicomponent injection allows refining the ne, ⟨Ee⟩ ranges, reducing experimental uncertainty. Na/K injection is presented as a demonstration. The ⟨Ee⟩ and ne of a hydrogen discharge are found to be 600+600−300eV and 8+8−3×1011cm−3, respectively. The ionization, charge exchange, and confinement times of high charge state alkali ions are on…