0000000000016159

AUTHOR

Busert C

showing 2 related works from this author

Frameless Neuronavigation Applied to Endoscopic Neurosurgery

2000

Objective: We retrospectively analyzed the indications, surgical techniques, and applicability of frameless neuronavigation to endoscopic procedures in a heterogeneous group of 15 patients. Material and Methods: In 8 patients indications for surgery were cystic lesions, in 3 patients intraventricular tumors, and in 4 patients occlusive hydrocephalus. The mean age was 39 years (range 9 - 76 years). The follow-up period ranged from 5 - 24 months (mean 10 months). Frameless neuronavigation was accomplished with the “operating arm system” in 10 cases and with the “optical tracking system” in 5 cases (RADIONICS, Burlington, USA). Results: In all 15 cases, neuronavigation sufficiently provided an…

AdultMaleVentriculostomymedicine.medical_specialtyNeuronavigationAdolescentmedicine.medical_treatmentIntraventricular tumorNeurosurgical ProceduresThird ventriculostomyHumansMedicineChildAgedRetrospective StudiesEndoscopesEndoscopic neurosurgeryBrain DiseasesPreoperative planningbusiness.industryCalibration ErrorEndoscopyEquipment DesignGeneral MedicineMiddle Agedmedicine.diseaseSurgeryHydrocephalusFemaleSurgeryNeurology (clinical)businessmin - Minimally Invasive Neurosurgery
researchProduct

Stereotactic biopsies guided by an optical navigation system: technique and clinical experience.

2002

Frame-based stereotactic biopsies are time-consuming procedures making necessary head fixation in a ring, explicit coordinate calculation and setting of the parameters. Frameless systems make many of these intermediate steps unnecessary, impose less mechanical restrictions regarding access to the lesions, and with slight modifications can be used to perform stereotactic biopsies. A special adaptation designed to fix the holder and the biopsy instrument is described. The neuronavigation optical tracking system of Radionics was used. CT scans were performed with 6 skin markers. Calibration was performed after head fixation in the Mayfield clamp. Mean calibration error was 2.19 +/- 0.81 mm. Th…

AdultMalemedicine.medical_specialtyStereotactic biopsyNeuronavigationTime FactorsAdolescentVisual controlStereotaxic TechniquesBiopsymedicineHumansChildAgedBrain Diseasesmedicine.diagnostic_testbusiness.industryBiopsy NeedleGeneral MedicineMiddle AgedCannulaSurgeryOptical navigationClampSurgery Computer-AssistedRadionicsSurgeryFemaleNeurology (clinical)businessNuclear medicineTomography X-Ray ComputedMinimally invasive neurosurgery : MIN
researchProduct