0000000000020690

AUTHOR

M. Kämmerer

The Public-Key-Infrastructure of the Radiological Society of Germany.

Pretty Good Privacy (PGP) encoding is based on the Public-Key-Procedure and permits the safe transmission of medical data. Furthermore it allows the use of an electronic signature provided that keys used belong to the key owner and that the key owner's identity is guaranteed by a trusted third party. Under the auspices of the Radiological Society of Germany (Deutsche Rontgengesellschaft, DRG) its IT-Working Group (Arbeitsgemeinschaft fur Informationstechnik, @GIT) built up an appropriate Certification Authority including the required Public-Key-Infrastructure. These @GIT certified PGP keys allow the legal use of telemedicine in Germany. Digital signatures based to those certified keys corre…

research product

Teleradiologie nach Röntgenverordnung - beispielhafte Anwendung der Open-Source-Software SecTelMed

Purpose: Establishing a teleradiology connection according to the Rontgenverordnung (RoV) between a peripheral hospital and a university clinic will contribute to improve the radiological emergency treatment on weekends, holidays and at night. It will also better the medical care for patients and help to lower the costs. Materials and Methods: By using the open source software SecTelMed, the radiological picture is transferred via an internet-linked SSH communication server. The integration of the teleradiological data transfer into the actual workflow is attained by using the already existing PACS infrastructure. While its installation is still under construction, it is actually employed f…

research product

DICOM E-mail: Germany's minimum standard for teleradiology

Abstract Due to the lack of a standard for teleradiology, the IT Working Group (Arbeitsgemeinschaft fur Informationstechnik, @GIT) of the German Radiological Society (Deutsche Rontgengesellschaft, DRG) has set up an initiative for standardizing telemedicine. E-mail has been selected as the ideal basis for ad hoc connections in teleradiology since it is both easy to implement and use. The DICOM standard offers the option of appending DICOM data types as MIME attachments to any e-mail, thus enabling the transmission of the original DICOM data. Nevertheless, there are additional requirements (e.g., data privacy) that must be obeyed and implemented. The first recommendation was introduced at th…

research product

Teleradiologie mit DICOM E-mail: Empfehlungen der @GIT

E-mail is ideal for ad-hoc connections in teleradiology. The DICOM standard offers the possibility to append DICOM data types as a MIME attachment to any e-mail, thus ensuring the transmission of the original DICOM data. Nevertheless, there are additional requirements (e.g. protection of data privacy) which must be obeyed. Because of the lack of given standards which would grant interoperability as well as manufacturer independence, teleradiology has not been established in Germany until today. Therefore, the IT-Team (Arbeitsgemeinschaft fur Informationstechnologie, @GIT) of the Radiological Society of Germany (Deutsche Rontgengesellschaft, DRG) set up an initiative to standardise telemedic…

research product