0000000000025521

AUTHOR

C. Sarno

Valutazione comparativa delle sequenze fast Spin-echo e Spin-echo T2-dipendenti nella dimostrazione delle lesioni demielinizzanti encefaliche in corso di sclerosi multipla

We compared T2-weighted fast spin-echo (FSE) magnetic resonance (MR) imaging and conventional spin-echo (CSE) T2-weighted imaging in the detection of brain lesions of multiple sclerosis (MS). 20 patients with clinically definite MS underwent brain imaging with both FSE and CSE T2-weighted imaging. There was no significant difference in total number of lesions detected on FSE vs CSE (1354 vs 1378). Slightly more periventricular and subcortical lesions were detected using CSE than FSE, whereas more posterior cranial fossa lesions were detected by FSE. There was no statistically significant difference in the signal intensity (SI) ratio of MS lesions to that of surrounding normal white matter …

research product

Familial Cavernous Angioma: MRI Study of three Generation in two Italian Families and Literature Review

According to recent magnetic resonance imaging studies, cavernous angioma (CA) seems to involve the central nervous system in 0.5%-1% of the population 1 - in a similar percentage to a large autopsy series 2.The incidence of familial CA is unknown 3: the first paper in the literature concerning familial CA was published in 1936 5: recently however, thank to the widespread use of MR, at least 13 families have been described.We report MR findings in two Italian families with familial CA.In conclusion, familial CA should be included in the differential diagnosis of patients with intracranial haemorrhage, seizures or cerebrovascular disease.

research product

Brain damage in hanging: A new CT finding

We report a 23-year-old man who attempted suicide by hanging. There have been few reports of involvement of the brain parenchyma shown on CT, all showing ischaemic lesions. This is the first report of multifocal intracerebral haematomas due to hanging seen on CT.

research product

Fast Spin Echo e Spin-Echo

Uno dei maggiori problemi connessi alio studio del SNC di pazienti in età pediatrica con RM è indubbiamente costituito dalla durata dell'esame stesso, che impone sovente la necessità di una sedazione farmacologica del paziente e limita allo stretto indispensabile il numero delle acquisizioni effettuate. Appare pertanto facilmente intuibile l'entusiasmo rivolto verso nuovi tipi di sequenze che presentino quale caratteristica principale una drastica riduzione dei tempi di acquisizione pur mantenendo un'affidabile qualità diagnostica. Le sequenze di tipo Fast-Spin-Echo (FSE) costituiscono il successivo sviluppo delle sequenze denominate RARE (Rapid Acquisition Relaxation Enhanced) descritte d…

research product