0000000000025614
AUTHOR
María José Luque
Analyzing the metrics of the perceptual space in a new multistage physiological colour vision model
In this work, the metric of a new multistage colour vision model, ATTD05, is assessed and a new colour difference formula is suggested. Firstly, the uniformity of the ATTD05 colour space was compared with that of CIECAM02 for some Munsell samples, because if the model yields a uniform perceptual space, we will be able to implement a colour difference formula as a Euclidian distance between two points. Secondly, we developed a new space based on the perceptual descriptors of the model: brightness, hue, colourfulness, and saturation. After that, we calculated the free parameters of the space that better fit the measured and experimental data of two datasets (small-magnitude and large-magnitud…
Concerning the calculation of the color gamut in a digital camera
Several methods to determine the color gamut of any digital camera are shown. Since an input device is additive, its color triangle was obtained from their spectral sensitivities and it was compared with the theoretical sensors of Ives-Abney-Yule and MacAdam. On the other hand, the RGB digital data of the optimal or MacAdam colors were simulated to transform them into XYZ data according to the colorimetric profile of the digital camera. From this, the MacAdam limits associated to the digital camera are compared with the corresponding ones of the CIE-1931 XYZ standard observer, resulting that our color device has much smaller MacAdam loci than those of the colorimetric standard observer. Tak…
New iPAD-based test for the detection of color vision deficiencies.
Purpose: To develop and validate a new iPad-based color vision test (Optopad). Methods: A total of 341 student eyes were enrolled in a first comparative study between Optopad and the Isihara tests. In a second comparative study, Optopad vs. the Farnworth-Munsell test (FM 100H), a total of 66 adult eyes were included. Besides the agreement between tests, the correlation between FM 100H and Optopad outcomes were investigated. Multiple regression analysis was used to predict the total error score (TES) from contrast thresholds measured with the Optopad test. Results: The Ishihara and Optopad tests detected the same anomalous patients. Concerning FM 100H vs. Optopad, 10 subjects were diagnosed …
On saturation and related parameters following Guth's ATD colour-vision model
In this work, we have examined the influence of different parameters both on perceived saturation and saturation discrimination with unrelated colours, on the basis of S. L. Guth's CA90 colour-vision model and its subsequent modifications. Our analysis of perceived saturation covered (1) spectral saturation functions at constant luminance, (2) saturation functions in constant colorimetric purity loci, (3) saturation vs. colorimetric purity functions, (4) saturation vs. luminance functions in the 1–1000 td range, and, finally, (5) the equal saturation loci in the xy color diagram. Regarding saturation discrimination, we focused on (1) saturation thresholds from white and from the locus, (2) …
Implementations of a novel algorithm for colour constancy
AbstractIn agreement with the principles of the relativistic model proposed by Creutzfeldtet al., with the photometric rule (lightness anchoring rule) and with the influence of simultaneous contrast in the appearance of a visual scene, we propose a first-stage mechanism yielding substantial colour constancy. We have defined a set of first-stage colour descriptors, and to test their utility, we have performed a simulation using a Machine Vision System (MVS). The statistical stability of the descriptors for Munsell samples under different illuminants is good.
Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients
Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…
Corresponding-pair procedure: a new approach to simulation of dichromatic color perception.
The dichromatic color appearance of a chromatic stimulus T can be described if a stimulus S is found that verifies that a normal observer experiences the same sensation viewing S as a dichromat viewing T. If dichromatic and normal versions of the same color vision model are available, S can be computed by applying the inverse of the normal model to the descriptors of T obtained with the dichromatic model. We give analytical form to this algorithm, which we call the corresponding-pair procedure. The analytical form highlights the requisites that a color vision model must verify for this procedure to be used. To show the capabilities of the method, we apply the algorithm to different color vi…
Software for simulating dichromatic perception of video streams
We have designed a configurable stand-alone Matlab-based software to simulate dichromatic perception of video streams. The algorithm used is an extension for video streams of the “corresponding pair algorithm” by Capilla and coworkers for simulation of dichromatic perception of images. The software allows the user to upload a video sequence and to process it using different dichromatic color vision models and viewing conditions. The output video may be generated in different spatial and temporal resolutions and file formats. The functions for Matlab environment and a stand-alone application may be downloaded from the Repository of the University of Alicante. © 2013 Wiley Periodicals, Inc. C…
Can Applications Designed to Evaluate Visual Function Be Used in Different iPads?
SIGNIFICANCE: Apple devices could be suitable for vision tests, provided that the test has been correctly adapted to the device, after considering the spatial and colorimetric characterization of the screen. PURPOSE: The majority of vision applications has not been developed by vision or colorimetry experts and suffers from conceptual and design errors that may lead average users to an erroneous assessment of their visual capabilities. The reliability of vision tests depends on the accurate generation of the necessary visual stimuli in a particular device. Our aim was to ascertain whether a given color test, designed for a colorimetrically characterized device, might be used in another simi…
Visual fields in a chloroquine treatment
Purpose: In this study, we describe contrast sensitivity losses in the visual field of a patient affected by chloroquine toxicity, measured with stimuli favoring different visual mechanisms. We have compared these results with those of other, usual clinical tests. Methods: The vision of a patient who underwent ten years of chloroquine treatment was analyzed by a battery of clinical tests: visual acuity (VA), Amsler’s grid, Farnsworth–Munsell 100-hue test, spectral domain optical coherence tomography, multifocal electroretinogram (ERG), white-on-white and red-on-white Humphrey perimetries, chromatic and achromatic contrast sensitivity perimetry tests, and fluorescein angiography. Measurement…
Colorimetric Characterization of Mobile Devices for Vision Applications
Purpose: Available applications for vision testing in mobile devices usually do not include detailed setup instructions, sacrificing rigor to obtain portability and ease of use. In particular, colorimetric characterization processes are generally obviated. We show that different mobile devices differ also in colorimetric profile and that those differences limit the range of applications for which they are most adequate. Methods: The color reproduction characteristics of four mobile devices, two smartphones (Samsung Galaxy S4, iPhone 4s) and two tablets (Samsung Galaxy Tab 3, iPad 4), have been evaluated using two procedures: 3D LUT (Look Up Table) and a linear model assuming primary constan…
Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes
Color perimetry has interesting clinical application for the diagnosis and detection of certain eye conditions, due to the variations that certain diseases can cause in chromatic thresholds, both in the red-green (RG) and the blue-yellow (BY) pathways.[1,2,3,4] The separate study of the visual function of both the chromatic and achromatic mechanisms could be more efficient in detecting sensitivity variations, and such variations would not be obscured by the intrusion of other mechanisms. Currently, the supply of conventional perimeters that are capable of performing a chromatic perimetry test is very limited and with reduced options regarding the possibility of choosing the physical charact…