0000000000026658
AUTHOR
Stefano Franchi Bononi
Pulsed Electro-Acoustic Method for specimens and cables employed in HVDC systems: Some feasibility considerations
Recent experiments on the use of the PEA method for testing dielectric materials in specimens and comparison with a detailed model provide an insight of the phenomenon and suggest the need of adopting similar models also for cables. What is said is even more important considering the possible future adoption of the PEA methodology to test DC cables for Pre-Qualification and Type Tests. The use of an accurate model of the PEA cell used for testing specimens and related experiments prove that the thickness of the different parts composing the PEA setup is a basic element for providing accurate charge reading and interpretation of the phenomenon. Both simulation and experimental results, carri…
Use of Time-Frequency map combined with DBSCAN algorithm for separation of partial discharge pulses under DC voltage
The Phase-Resolved-Partial-Discharge pattern (PRPD) is a conventional technique used for the evaluation of partial discharges (PD) phenomena in High-Voltage-Alternating-Current (HVAC) systems. This map is constructed by plotting the peak of each detected pulses as a function of the phase angle of the supply voltage. Therefore it is obvious that this technique cannot be used for the analysis of data from PD mesaurement under different supply voltage condition (DC). The aim of this paper is to evaluate the application of the Time-Frequency map (TF map) for the analysis of a dataset obtained from PD measurement under DC voltage. A density-based clustering algorithm was also used to gain more i…
Wireless partial discharge tracking on cross-linked polyethylene MV and HV cables
Medium voltage (MV)/high voltage (HV) cable lines are high-value assets and require substantial costs for their installation or replacement. For this reason, the capability to assess the condition of cable lengths and accessories on site is of great importance. Cross-linked polyethylene (XLPE) insulation is extensively used for MV, HV, and extra-high voltage (EHV) class cables [1] thanks to its excellent voltage-endurance and thermomechanical properties. In particular, XLPE-insulated cables feature substantially lower losses, easier manufacturing and jointing procedures, better environmental compatibility, and higher operating temperature compared with impregnated paper cables, which lead t…
Critical issues in the PD testing methodology for XLPE-insulated MV cables: An experimental case
This paper describes some critical issues arising during the partial discharge (PD) testing of a 500m delivery length of an XLPE-insulated MV cable. At first, conventional PD measurements were performed on the whole length by using a standard acquisition system; PDs activity was detected, but the system allowed the operator to localize the PDs only on a length of 70 m. A visual inspection of this section highlighted the presence of an excoriation in the outer sheet. Aiming at a more accurate pin-pointing of the defect, more measurements were carried out in the proximity of the outer defect using a portable PD detection system. These measurements showed PDs activity, whose source was located…
The effect of Transient over Voltages on the Partial Discharges activity in HVDC joints
Rapid growth of HVDC cable line installations is expected in the coming years. Several research groups have investigated dielectric phenomena that occur in the insulation of HVDC cables and accessories that accelerate aging and reduce the reliability of this technology over time. Unlike in HVAC cables, under HVDC stress, the distribution of the electric field inside the insulation layer depends not only on the applied voltage but also on the temperature distribution and on other factors related to manufacturing such as the presence of impurities. Reaching local and transient electric field peaks can enhance the onset of Partial Discharges (PDs) which can lead to premature aging of the insul…