0000000000033322
AUTHOR
K. Walter
Determination of90Sr in environmental samples with resonance ionization spectroscopy in collinear geometry
A new, fast technique for trace analysis of the radioactive isotopes89Sr and90Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the90Sr content in ≈ 870 m3 air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of90Sr was measured to be 1.4 mBq per m3, corresponding to 1.6 × 109 atoms of90Sr per sample. This value is in good agreement with the results…
The Nutcracker Syndrome: New Aspects of Pathophysiology, Diagnosis and Treatment
Magnetic resonance imaging (MRI) was used to study vascular anatomy in 3 patients with the nutcracker syndrome and in 10 healthy volunteers. From these studies an abnormal branching of the superior mesenteric artery from the aorta was identified as being the cause of the nutcracker syndrome. Consequently, surgical transposition of the left renal vein to achieve an unobstructed renal venous backflow was performed successfully in 2 patients, while 1 underwent nephrectomy. In 1 patient adjuvant ureteral instrumentation became necessary to aid occlusion of persisting shunts between peripelvic venous varicosities and the urinary tract. Awareness of the pathophysiology of the nutcracker syndrome …
Fast, low-level detection of strontium-90 and strontium-89 in environmental samples by collinear resonance ionization spectroscopy
Environmental assessment in the wake of a nuclear accident requires the rapid determination of the radiotoxic isotopes 89Sr and 90Sr. Useful measurements must be able to detect 108 atoms in the presence of about 1018 atoms of the stable, naturally occurring isotopes. This paper describes a new approach to this problem using resonance ionization spectroscopy in collinear geometry, combined with classical mass separation. After collection and chemical separation, the strontium from a sample is surface-ionized and the ions are accelerated to an energy of about 30 keV. Initially, a magnetic mass separator provides an isotopic selectivity of about 106. The ions are then neutralized by charge exc…
Trace Analysis of the Radionuclides90Sr and89Sr in Environmental Samples I: Laser Mass Spectrometry
Quantitative Detection of Strontium-90 and Strontium-89 in Environmental Samples by Laser Mass Spectrometry
Parallel to the strongly growing public concern about environmental problems, new ideas for trace detection and analysis of toxic and radioactive material are being developed. One of these new and outstanding experimental techniques is the application of analytical laser spectroscopy. Most interesting in this context is the method of resonance ionization spectroscopy (RIS), as proposed1 already in 1972 combining very high sensitivity in the detection of the element or isotope under investigation with high selectivity in the suppression of contaminants2–4.