0000000000040243

AUTHOR

B. Gómez-taylor Corominas

A tandem-flow assembly for the chemiluminometric determination of hydroquinone

A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic int…

research product

In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine

[EN] A flow injection analysis (FIA) manifold for the determination of penicillamine in pharmaceutical preparations is proposed. The manifold includes a solid-phase reactor for the in situ production of the derivatizing reagent, Co(II) ion, which forms a coloured complex with penicillamine in an alkaline medium. The reactor is prepared by natural immobilization of cobalt carbonate on a polymer matrix, which endows it with a high mechanical and microbiological stability. The cobalt released by passage of a 5 x 10(-4) Mol l(-1) sulphuric acid stream at a flow-rate of 2.3 ml min(-1) is merged with a volume of 314 mu l of sample containing penicillamine in ammonium-ammonia buffer at pH 9.5 to m…

research product

Determination of Phenol by Preconcentration‐Direct Chemiluminescence in a FIA Assembly

Abstract The determination of phenol in water samples is proposed with the aid of a flow‐injection system. The analytical procedure is based on the direct chemiluminometric emission by oxidation of the analyte with potassium permanganate in acidic medium. The flow assembly is provided with a solid‐phase reactor filled with a resin type XAD‐4 for analyte preconcentration. A large study of potential interferences, namely, amino acids reaching water through degradation of organic matter; metals and inorganic metal ions typically present in water interfering with the CL emission of the parent compound, was performed. The calibration graph was linear over the phenol concentration range 1.0–20.0 …

research product

Prediction of the chemiluminescent behaviour of phenols and polyphenols.

Abstract A paper from this laboratory ‘J. Anal. Chem. 73 (2001) 4301’ was recently published and dealing with the first attempt to apply molecular connectivity calculations to predict a chemical property with analytical usefulness; namely, the chemiluminescent behaviour of substances when react with common strong oxidants in liquid phase. In the present work, the usefulness of molecular topology on the search for new chemiluminescent compounds is clearly demonstrated. The proposed discriminant equation, represented a success of 92.7% in the prediction. The present paper is the further step from the cited paper; it is dealing on the application of molecular connectivity calculations (former …

research product

Determination of tannic acid by direct chemiluminescence in a FIA assembly

The determination of tannic acid is performed in a FIA assembly on the basis of the analytical output obtained by oxidation of the acid. The analyte solution was daily prepared in a mixture of quinine as sensitiser and perchloric acid and it was injected into a pure water stream acting as a carrier. This solution merges with the mixture potassium permanganate in perchloric medium and the resulting chemiluminescence is monitored. The method was applied over the range 0.5-20 mg l(-1) of tannic acid with a LOD 100 mug l(-1). The reproducibility was 2.1% and the sample throughput 54 h(-1). The influence of foreign substances was studied and the new method is applied to the determination of tann…

research product