D Paolucci
Efficacy of four cleaning solutions for the decontamination of selected cytotoxic drugs on the different surfaces of an automated compounding system
The automated aseptic preparation of ready-to-administer antineoplastic drug solutions with robotic systems reduces the risk of occupational exposure. However, the surfaces in the preparation area of the robot are to be cleaned by wiping with an appropriate cleaning solution. The aim of the study was to evaluate the cleaning efficacy of four cleaning solutions on four surface materials installed in the APOTECAchemo robot. Predefined amounts of cisplatin (Cis), 5-fluorouracil (5-FU), and cyclophosphamide (CP) were intentionally spread on test plates made of stainless steel, aluminium, polyoxymethylene, and polycarbonate just as installed in the robotic system APOTECAchemo. After drying, the …
Robotic i.v. medication compounding: Recommendations from the international community of APOTECAchemo users.
Purpose The development of recommendations for advancing automated i.v. medication compounding is described. Summary Managing the shift from manual to robotic compounding of i.v. therapies requires an awareness of how automation affects practice and how to best implement robotics into current practice. An international panel of pharmacy professionals, researchers, and technology leaders with experience in i.v. robotics collaborated during a two-day meeting in August 2014 to define a general set of principles to broaden the understanding of the fundamental elements of robotic compounding worldwide. Participants were divided into four working groups (technology and safety; drugs and products;…