0000000000041496

AUTHOR

Rudolf Schierl

Efficacy of four cleaning solutions for the decontamination of selected cytotoxic drugs on the different surfaces of an automated compounding system

The automated aseptic preparation of ready-to-administer antineoplastic drug solutions with robotic systems reduces the risk of occupational exposure. However, the surfaces in the preparation area of the robot are to be cleaned by wiping with an appropriate cleaning solution. The aim of the study was to evaluate the cleaning efficacy of four cleaning solutions on four surface materials installed in the APOTECAchemo robot. Predefined amounts of cisplatin (Cis), 5-fluorouracil (5-FU), and cyclophosphamide (CP) were intentionally spread on test plates made of stainless steel, aluminium, polyoxymethylene, and polycarbonate just as installed in the robotic system APOTECAchemo. After drying, the …

research product

Robotic i.v. medication compounding: Recommendations from the international community of APOTECAchemo users.

Purpose The development of recommendations for advancing automated i.v. medication compounding is described. Summary Managing the shift from manual to robotic compounding of i.v. therapies requires an awareness of how automation affects practice and how to best implement robotics into current practice. An international panel of pharmacy professionals, researchers, and technology leaders with experience in i.v. robotics collaborated during a two-day meeting in August 2014 to define a general set of principles to broaden the understanding of the fundamental elements of robotic compounding worldwide. Participants were divided into four working groups (technology and safety; drugs and products;…

research product

Environmental and Product Contamination during the Preparation of Antineoplastic Drugs with Robotic Systems

Abstract Background Robotic systems are designed to minimize the exposure to antineoplastic drugs during automated preparation. However, contamination cannot be completely excluded. The aim of the study was to evaluate the contamination with antineoplastic drugs on the working surfaces and on the outer surface of the ready-to-use products (infusion bags and syringes) during automated preparation with different versions of a robot and manual preparation. Methods Surface contamination with platinum (Pt) and 5-fluorouracil (5-FU) was measured by wipe sampling and quantified by voltammetry for Pt and GC-MS for 5-FU. Sampling was performed on pre-defined locations in the working areas before and…

research product