Inspection of architectural structures with integrated electrical methodologies and infrared thermography
B030 INSPECTION OF ARCHITECTURAL STRUCTURES WITH INTEGRATED ELECTRICAL METHODOLOGIES AND INFRARED THERMOGRAPHY Abstract 1 The attention of this paper was focused on the detection of moisture and local inhomogeneities inside architectural structures with electrical methodologies and infrared thermography. To this end a suitable specimen was fabricated using a mixture of sand water and concrete and with slag inclusions. To monitor the moisture variation with time in concrete nondestructive evaluation with both the techniques was made three months after the specimen fabrication and repeated again six months later. Introduction The inspection of architectural structures generally includes vario…
The Contribution of Electrical Resistivity Measurements to the Analysis of Landslide Events
In order to gain insight into the study of natural avalanches dynamics, we illustrate a statistical model based on a dissipative dynamical variable associated to a position dependent factor of safety field. This model, as experimentally demonstrated, is able to reproduce the complex structure of landslide events, such as power-law distributions. In this paper, we introduce an explicit dependence of the safety factor on the electrical resistivity to simulate landslide events in pyroclastic soils. An application of the model to data acquired in a test area characterized by flowslide events (Monte Albino, Campania Region - South Italy) bear witness the relevant role played by the resistivity m…