Broad beam transmission data for the shielding of brachytherapy facilities

2008

medicine.medical_specialtyOpticsOncologybusiness.industrymedicine.medical_treatmentElectromagnetic shieldingBrachytherapymedicineRadiology Nuclear Medicine and imagingMedical physicsBeam transmissionbusinessBrachytherapy
researchProduct

Design and evaluation of a HDR skin applicator with flattening filter

2008

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…

Materials scienceDosimeterbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomKermaOpticsIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

SU-FF-T-365: Practical Reconstruction Method for 3D CT-Based Brachytherapy with Shielded Colpostats

2006

Introduction and purpose.‐ The most extended worldwide HDR and PDR afterloading machines are from Nucletron, using the Plato Treatment Planning System (TPS) to perform the clinical dosimetry. The Fletcher‐Williamson (FW) vaginal colpostat applicators are widely used with these machines, they are made of a very dense material (densimet‐17) which allows shielding up to 50% of the dose. Almost all the TPS have incorporated the CT‐Based Brachytherapy (BT), in which the CT catheters and applicators reconstruction is based on contiguous CT transverse slices where the user points the catheter position. The problem with these applicators is the production of artefacts that makes the reconstruction …

Contouringmedicine.diagnostic_testComputer sciencebusiness.industrymedicine.medical_treatmentBrachytherapyComputed tomographyGeneral MedicineReconstruction methodImaging phantomlaw.inventionCatheterlawBreast implantShielded cablemedicineDosimetryClinical dosimetryRadiation treatment planningNuclear medicinebusinessMedical Physics
researchProduct

The use of nomograms in LDR-HDR prostate brachytherapy

2011

Purpose: The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adapt ed to High Dose Rate (HDR). This work sets nomograms for LDR and HDR prostate-BT implants, which are applied to three different institutions that use different implant techniques. Material and methods: Patients treated throughout 2010 till April 2011 were considered for this study. This exam ple was chosen to be the representative of the latest implant tech…

medicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentlcsh:RBrachytherapylcsh:MedicinePermanent prostate brachytherapyquality assuranceNomogramprostate brachytherapyKermaOncologymedicineDosimetryOriginal ArticleRadiology Nuclear Medicine and imagingMedical physicsbusinessDose rateindependent verificationQuality assuranceProstate brachytherapynomogramsJournal of Contemporary Brachytherapy
researchProduct

Reply to “Comment on ‘Correspondence factor for Nucletron surface applicators'” [Med. Phys. 39, 2947-2948 (2012)]

2012

PhysicsSurface (mathematics)OpticsCalibration (statistics)business.industryGeneral MedicinebusinessMedical Physics
researchProduct

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

2008

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calc…

medicine.medical_specialtyMaterials sciencePhotonbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineRadiationComputational physicsElectromagnetic shieldingmedicineMedical physicsRadiation protectionbusinessHalf-value layerBeam (structure)Medical Physics
researchProduct

Broad beam transmission curves for new radionuclides in brachytherapy

2007

Radionuclidemedicine.medical_specialtyOncologybusiness.industryNuclear engineeringmedicine.medical_treatmentBrachytherapyMedicineRadiology Nuclear Medicine and imagingMedical physicsBeam transmissionbusinessBrachytherapy
researchProduct