0000000000065118
AUTHOR
Dietrich Beck
High-accuracy mass determination of unstable cesium and barium isotopes
Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\delta \mbox{m} \approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.
On-line commissioning of SHIPTRAP
Abstract The on-line commissioning of the Penning-trap mass spectrometer SHIPTRAP was successfully completed with a mass measurement of holmium and erbium radionuclides produced at SHIP. A large fraction of contaminant ions created in the stopping cell was identified to originate from the buffer-gas supply system. Using a liquid nitrogen cold trap they were reduced to a tolerable amount and mass measurements of Er 147 , Er 148 , and Ho 147 with relative uncertainties of about 1 × 1 0 − 6 were performed.
Bunching and cooling of radioactive ions with REXTRAP
The properties of radioactive ion beams produced by the present on-line target ion source technology are often not suitable for direct post acceleration. For that purpose pulsed and cooled beams of higher charged ions are required. In the case of REX-ISOLDE, the post accelerator at the CERN-ISOLDE radioactive beam facility, a unique system for beam preparation is used. It consists of a gas-filled cylindrical Penning trap (REXTRAP) for bunching and cooling followed by an electron beam ion source for charge state breeding. The Penning trap has been successfully operated with an efficiency of up to 40% and a total number of up to 107 ions stored. Buffer-gas sideband cooling at the ions’ cyclot…
ISOLTRAP mass measurements of exotic nuclides at
The ISOLTRAP experiment at the ISOLDE facility at CERN is a Penning trap mass spectrometer for on-line mass measurements on short-lived radionuclides. It allows the determination of atomic masses of exotic nuclides with a relative uncertainty of only 10−8. The results provide important information for, e.g., weak interaction studies and nuclear models. Recent ISOLTRAP investigations and applications of high-precision mass measurements are discussed.
Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer
Abstract The masses of Xe isotopes with 124⩾ A ⩾114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm ≈12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found.
Isoltrap pins down masses of exotic nuclides
The mass of radionuclides contribute to a variety of fundamental studies including tests of the weak interaction and the Standard Model. The limits of mass measurements of exotic nuclides have been extended considerably by the Penning-trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN. Recent ISOLTRAP measurements are summarized and current technical improvements are outlined.
TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz
The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as a beam line for collinear laser spectroscopy are being installed. Several new developments will ensure high sensitivity of the trap setup enabling mass measurements even on a single ion. Besides neutron-rich fission products produced in the reactor, also heavy nuclides such as 235-U or 252-Cf can be investigated for the first time with an off-line ion source. The data provided by the mass measurements will be of interest for astrophysical calculations on…
Direct determination of the mass of28Si as a contribution to a new definition of the kilogram
The mass of 28Si has been determined to be m(28Si) = 27.976 926 57(30) u by comparing the cyclotron frequencies of the singly charged ions 12C+, 12C+3 and 28Si+ in a Penning trap mass spectrometer. The experimental technique and the setup are described. The obtained accuracy as well as possible improvements are discussed. Our measurements are related to current efforts to base the kilogram on atomic properties by using an almost perfect single crystal of silicon.
High-precision Penning-trap mass measurements of heavy xenon isotopes for nuclear structure studies
With the double Penning-trap mass spectrometer ISOLTRAP at ISOLDE/CERN the masses of the neutron-rich isotopes $^{136\ensuremath{-}146}\mathrm{Xe}$ were measured with a relative uncertainty of the order of ${10}^{\ensuremath{-}8}$ to ${10}^{\ensuremath{-}7}$. In particular, the masses of $^{144\ensuremath{-}146}\mathrm{Xe}$ were measured for the first time. These new mass values allow one to extend calculations of the mass surface in this region. Proton-Neutron interaction strength, obtained from double differences of binding energies, relate to subtle structural effects, such as the onset of octupole correlations, the growth of collectivity, and its relation to the underlying shell model l…
High-precision masses of neutron-deficient rubidium isotopes using a Penning trap mass spectrometer
The atomic masses of the neutron-deficient radioactive rubidium isotopes $^{74-77,79,80,83}$Rb have been measured with the Penning trap mass spectrometer ISOLTRAP. Using the time-of-flight cyclotron resonance technique, relative mass uncertainties ranging from $1.6 \times 10^{-8}$ to $5.6 \times 10^{-8}$ were achieved. In all cases, the mass precision was significantly improved as compared with the prior Atomic-Mass Evaluation; no significant deviations from the literature values were observed. The exotic nuclide $^{74}$Rb with a half-life of only 65 ms, is the shortest-lived nuclide on which a high-precision mass measurement in a Penning trap has been carried out. The significance of these…
Towards high-precision mass measurements on 74Rb for a test of the CVC hypothesis and the unitarity of the CKM matrix
At the highest possible precisions, atomic-mass measurements can be used to perform fundamental studies. Examples for such studies are a check of the conserved-vector-current (CVC) hypothesis and the unitarity of the Cabibbo-Kobayashi-Maskawa (CKM) matrix, both postulates of the Standard Model. The comparative half-lives Ft of superallowed β decays constitute the nuclear-physics access to these tests. The Q value of the β decay of 74 Rb, one of the three experimentally accessible parameters that enter into the Ft values, has been measured with the ISOLTRAP experiment at ISOLDE/CERN. The ultimate mass precision requirement and the way to achieve it are outlined.
Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides
The triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN has demonstrated the feasibility of mass spectrometry of in-trap-decay product ions. This novel technique gives access to radionuclides, which are not produced directly at ISOL-type radioactive ion beam facilities. As a proof of principle, the in-trap decay of $^{37}K^+$ has been investigated in a Penning trap filled with helium buffer gas. The half-life of the mother nuclide was confirmed and the recoiling $^{37}Ar^+$ daughter ion was contained within the trap. The ions of either the mother or the daughter nuclide were transferred to a precision Penning trap, where their mass was determined.
Accurate mass measurements on neutron-deficient krypton isotopes
soumis à Nuclear Physics A; The masses of $^{72-78,80,82,86}$Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for $^{72-75}$Kr outweighed previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for t…
Mass measurements of $^{56-57}$Cr and the question of shell reincarnation at N = 32
Binding energies determined with high accuracy provide smooth derivatives of the mass surface for analysis of shell and pairing effects. Measurements with the Penning trap mass spectrometer ISOLTRAP at CERN-ISOLDE were made for $^{56-57}$Cr for which an accuracy of 4 $\times 10^{-8}$ was achieved. Analysis of the mass surface for the supposed new N = 32 shell closure rather indicates a sub-shell closure, but of a different nature than known cases such as $^{94}$Sr.