0000000000065122

AUTHOR

M. König

showing 9 related works from this author

High-accuracy mass determination of unstable cesium and barium isotopes

1999

Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\delta \mbox{m} \approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

PhysicsNuclear and High Energy PhysicsIsotope[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]010308 nuclear & particles physicschemistry.chemical_element[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap7. Clean energy01 natural sciencesISOLTRAPAtomic massNuclear physicsMasschemistryCaesium0103 physical sciencesNuclear Physics - ExperimentAtomic physicsNuclear Experiment010306 general physicsHybrid mass spectrometer
researchProduct

High-accuracy mass determination of neutron-rich rubidium and strontiumiIsotopes

2002

The penning-trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of $^{88,89,90m,91,92,93,94}$Rb and $^{91- 95}$Sr. Using a resolving power of R $\!\scriptstyle\approx$1 million a mass accuracy of typically 10 keV was achieved for all nuclides. Discrepancies with older data are analyzed and discussed, leading to corrections to those data. Together with the present ISOLTRAP data these corrected data have been used in the general mass adjustment.

PhysicsNuclear and High Energy PhysicsIsotope010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap01 natural sciencesISOLTRAPAtomic massNuclear physics0103 physical sciencesMass spectrumNeutronNuclear Physics - ExperimentNuclideAtomic physics010306 general physics
researchProduct

Quadrupole excitation of stored ion motion at the true cyclotron frequency

1995

Abstract The motion of an ion in a Penning trap has been investigated in the presence of an azimuthal quadrupole radio frequency field and a damping force provided by buffer gas collisions. Analytical expressions are derived which describe the line shape of the cyclotron resonance as well as the properties of the mass-selective cooling mechanism for heavy ions. Excellent agreement is observed between theoretical results and experimental data obtained with the tandem Penning trap mass spectromer ISOLTRAP at ISOLDE (CERN).

ChemistryCyclotron resonancePhysics::Atomic PhysicsIon trapAtomic physicsQuadrupole ion trapNuclear ExperimentPenning trapQuadrupole mass analyzerISOLTRAPSpectroscopyFourier transform ion cyclotron resonanceIon cyclotron resonanceInternational Journal of Mass Spectrometry and Ion Processes
researchProduct

Dependence of fracture toughness of composite laminates on interface ply orientations and delamination growth direction

2004

A critical review has been performed of the published experimental research concerning delamination onset and growth in composite laminate interfaces of different lay-ups under single-mode loadings. It was found that, depending on the loading mode and interface lay-up, the traditional fracture toughness characterization by unidirectionally reinforced composite tests can lead to marked under- or overestimation of material resistance to crack growth. Empirical models of fracture toughness as a function of delamination front orientation with respect to reinforcement directions of the adjacent laminae have been validated and their applicability range established.

Fiber pull-outFracture toughnessMaterials scienceDelaminationComposite numberGeneral EngineeringCeramics and CompositesComposite materialComposite laminatesReinforcementExperimental researchComposites Science and Technology
researchProduct

A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams

1997

Abstract A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 10 5 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.

Nuclear and High Energy PhysicsIon beamChemistryMass spectrometryPenning trapIon gunISOLTRAPIon sourceNuclear physicsSecondary ion mass spectrometryPhysics::Accelerator PhysicsIon trapDetectors and Experimental TechniquesAtomic physicsNuclear ExperimentInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Is first-line single-agent mitoxantrone in the treatment of high-risk metastatic breast cancer patients as effective as combination chemotherapy? No …

2002

BACKGROUND: To determine whether patients with high-risk metastatic breast cancer draw benefit from combination chemotherapy as first-line treatment. PATIENTS AND METHODS: A total of 260 women with measurable metastatic breast cancer fulfilling high-risk criteria, previously untreated with chemotherapy for their metastatic disease, were randomized to receive either mitoxantrone 12 mg/m(2) or the combination of fluorouracil 500 mg/m(2), epirubicin 50 mg/m(2) and cyclophosphamide 500 mg/m(2) (FEC) every 3 weeks. Treatment was continued until complete remission plus two cycles, or until disease progression. In the case of partial remission or stable disease, treatment was stopped after 12 cycl…

OncologyAdultmedicine.medical_specialtyLung NeoplasmsCyclophosphamidemedicine.medical_treatmentBone NeoplasmsBreast NeoplasmsRisk AssessmentSensitivity and SpecificityDisease-Free SurvivalStatistics NonparametricInternal medicineGermanyAntineoplastic Combined Chemotherapy ProtocolsmedicineHumansCyclophosphamideAgedEpirubicinNeoplasm StagingProbabilityProportional Hazards ModelsChemotherapyMitoxantronePerformance statusbusiness.industryBiopsy NeedleLiver NeoplasmsCombination chemotherapyHematologyMiddle Agedmedicine.diseaseMetastatic breast cancerSurvival AnalysisSurgeryLogistic ModelsTreatment OutcomeOncologyQuality of LifeVindesineFemaleFluorouracilMitoxantronebusinessmedicine.drugEpirubicinAnnals of oncology : official journal of the European Society for Medical Oncology
researchProduct

Direct mass measurements of unstable rare earth isotopes with the ISOLTRAP mass spectrometer

1996

Abstract Direct mass measurements of neutron deficient rare earth isotopes in the vicinity of 146 Gd were performed for the first time with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Since ISOL-facilities deliver these isotopes with a large amount of isobaric contamination, these measurements became possible only after the installation of a new cooler trap which acts as an isobar separator. To date more than 40 isotopes of the elements Pr, Nd, Pm, Sm, Eu, Dy, and Ho have been measured with a typical accuracy of δm ≈ 14 keV. Some of these isotopes provide an important anchor for many other isotopes linked by known Q-values.

PhysicsNuclear and High Energy PhysicsIsotope010308 nuclear & particles physicsIsotopes of argon[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap01 natural sciences7. Clean energyISOLTRAPIsotopes of oxygenIsotopes of nitrogenNuclear physics13. Climate action0103 physical sciencesNeutronAtomic physics010306 general physicsNuclear Physics A
researchProduct

Resolution of nuclear ground and isomeric states by a Penning trap mass spectrometer.

1992

Ground and isomeric states of a nucleus have been resolved for the first time by mass spectrometry. Measurements on $^{78}\mathrm{Rb}^{\mathit{m},}$g and $^{84}\mathrm{Rb}^{\mathit{m},}$g were performed using a tandem Penning trap mass spectrometer on-line with the isotope separator ISOLDE/CERN. The effects of ion-ion interaction were investigated for two ion species differing in mass and stored simultaneously in the trap.

PhysicsNuclear and High Energy PhysicsIsotopeTandem010308 nuclear & particles physics[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex]Nuclear structure[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryPenning trap01 natural sciencesISOLTRAPIsotopes of rubidiumIon0103 physical sciencesNuclear Physics - ExperimentPhysics::Atomic PhysicsAtomic physicsNuclear Experiment010306 general physicsPhysical review. C, Nuclear physics
researchProduct

Towards higher accuracy with the ISOLTRAP mass spectrometer

1996

To now the masses of more than hundred unstable isotopes have been determined with the ISOLTRAP mass spectrometer installed at ISOLDE/CERN. Typically a resolving power of mΔm ≈ 1 × 106 was used and the mass determinations were assigned an accuracy of δmm ≈ 1 × 10−7. We show that with improvements to ISOLTRAP and refinements of the experimental technique an accuracy of δmm ≈ 3 × 10−8 can be obtained.

Nuclear and High Energy PhysicsLarge Hadron ColliderIsotope010308 nuclear & particles physicsChemistry[PHYS.NEXP] Physics [physics]/Nuclear Experiment [nucl-ex][PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Penning trapMass spectrometry01 natural sciencesISOLTRAPAtomic massNuclear physics0103 physical sciencesAtomic physics010306 general physicsInstrumentation
researchProduct