0000000000065125

AUTHOR

E. Schark

High-accuracy mass determination of unstable cesium and barium isotopes

Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\delta \mbox{m} \approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

research product

A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams

Abstract A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 10 5 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.

research product

The Stockholm–Mainz ion trap project

A new ion trap facility is described which is dedicated to studies of highly charged ions in a Penning trap. Such a trap will be connected to sources of highly charged ions, in particular the electron beam ion source CRYSIS, at the Manne Siegbahn Institute for Physics. The use of highly charged ions in a Penning trap increases the cyclotron frequency with a factor proportional to the charge which leads to a higher resolution. Also, the possibility to vary the charge state makes it possible to search for and identify different systematic effects. Thus, a substantial increase in accuracy can be expected. In addition, the combination of high charge state ions and a Penning trap allows new appl…

research product

Direct determination of the mass of28Si as a contribution to a new definition of the kilogram

The mass of 28Si has been determined to be m(28Si) = 27.976 926 57(30) u by comparing the cyclotron frequencies of the singly charged ions 12C+, 12C+3 and 28Si+ in a Penning trap mass spectrometer. The experimental technique and the setup are described. The obtained accuracy as well as possible improvements are discussed. Our measurements are related to current efforts to base the kilogram on atomic properties by using an almost perfect single crystal of silicon.

research product

Direct mass measurements of unstable rare earth isotopes with the ISOLTRAP mass spectrometer

Abstract Direct mass measurements of neutron deficient rare earth isotopes in the vicinity of 146 Gd were performed for the first time with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Since ISOL-facilities deliver these isotopes with a large amount of isobaric contamination, these measurements became possible only after the installation of a new cooler trap which acts as an isobar separator. To date more than 40 isotopes of the elements Pr, Nd, Pm, Sm, Eu, Dy, and Ho have been measured with a typical accuracy of δm ≈ 14 keV. Some of these isotopes provide an important anchor for many other isotopes linked by known Q-values.

research product