0000000000067454
AUTHOR
K. Krüger
Considerable deficits in the detection performance of the cat after lesion of the suprasylvian visual cortex
The ability of two cats to discriminate between two geometrical outline patterns in the presence of superimposed structured background was tested before and after bilateral removal of the lateral suprasylvian visual areas (PMLS, PLLS, AMLS, ALLS, part of area 7). There were mild deficits when patterns and background were kept stationary; these deficits may be due to a partial undercutting of areas 17, 18 and 19. However, there was a severe impairment in performance when the patterns were moving on a stationary background which may be due to loss of the suprasylvian visual areas. Movement of the background relative to the figure resulted in an intermediate detection deficit.
Contribution of area 19 to the foreground-background-interaction of the cat: an analysis based on single cell recordings and behavioural experiments.
The contribution of area 19 to pattern discrimination in the cat was studied by single cell recordings in this area and by behavioural experiments before and after bilateral lesions. In order to make quantitative comparisons between behavioural performance and that of cell systems, we introduced a new parameter that characterizes visual neurons by their signal-to-noise (S/N) thresholds. A structured visual background made up of Gaussian visual broadband noise which could be moved was superimposed on the signal (moving bars or outline patterns) and the S/N characteristics of the response were determined by varying the signal intensity. The detection performance of cats after bilateral lesion…
Lesion of areas 17/18/19: effects on the cat's performance in a binary detection task
The ability of two cats to discriminate between two geometrical outline patterns in the presence of superimposed Gaussian visual noise — i.e. in a binary detection task — was tested before and after bilateral removal of cortical areas 17, 18 and 19. The detection probability PD was measured as a function of the signal-to-noise ratio. After a lesion of areas 17, 18 and 19 both cats were unable to carry out the discrimination tasks. Their detection performance dropped to chance level, but after an extensive phase of retraining (3 months) they regained the ability to discriminate visual patterns. It was thus possible to obtain detection curves and to determine a measure of a performance which …
Detection performance of normal cats and those lacking areas 17 and 18: a behavioral approach to analyse pattern recognition deficits.
The ability of cats to discriminate between two geometrical outline patterns in the presence of superimposed Gaussian visual noise was tested before and after bilateral removal of cortical area 17 and parts of area 18. The detection probability PD was measured as a function of the signal-to-noise ratio for the parameters: noise bandwidth, spatial frequency content and rate of movement of patterns. In both normal and lesioned cats a broadband noise was found to be most effective in masking the large patterns while two other types of noise, a medium frequency noise and a high frequency noise had little or no masking effect. For recognition of the smaller patterns in normal cats the medium fre…
Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV
A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20 to 350 GeV and beam impact points and angles corresponding to pseudorapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit.
Study of the response of the ATLAS central calorimeter to pions of energies from 3 to 9 GeV
Çetin, Serkant Ali (Dogus Author) A fully instrumented slice of the ATLAS central detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the response of the central calorimeters to pions with energies in the range between 3 and 9 GeV is presented. The linearity and the resolution of the combined calorimetry (electromagnetic and hadronic calorimeters) was measured and compared to the prediction of a detector simulation program using the toolkit Geant 4.
The Fifth International Workshop on Ice Nucleation phase 2 (FIN-02): Laboratory intercomparison of ice nucleation measurements
The second phase of the Fifth International Ice Nucleation Workshop (FIN-02) involved the gathering of a large number of researchers at the Karlsruhe Institute of Technology's Aerosol Interactions and Dynamics of the Atmosphere (AIDA) facility to promote characterization and understanding of ice nucleation measurements made by a variety of methods used worldwide. Compared to the previous workshop in 2007, participation was doubled, reflecting a vibrant research area. Experimental methods involved sampling of aerosol particles by direct processing ice nucleation measuring systems from the same volume of air in separate experiments using different ice nucleating particle (INP) types, and coll…