0000000000067849
AUTHOR
Sebastian Gregor
Human leukocyte elastase counteracts matrix metalloproteinase-7 induced apoptosis resistance of tumor cells.
Matrix metalloproteinase-7 (MMP-7/Matrilysin) is a component of the tumor microenvironment associated with malignant progression. Its expression in tumors protects tumor cells from CD95-mediated apoptosis and the cytotoxic activity of tumor specific CD8(+) T cells. In the present study, we show that human leukocyte elastase (HLE) secreted by polymorphonuclear leukocytes cleaves MMP-7 resulting in loss of enzymatic activity. The anti-apoptotic effect of MMP-7 is reduced in the presence of HLE for CD95-, doxorubicin- and CTL-mediated apoptosis. Our data indicates that HLE may be a natural inactivator of MMP-7 which can counteract MMP-7-induced apoptosis resistance.
In vivo molecular and morphological imaging by real time confocal mini-microscopy
We evaluated a newly developed miniaturized confocal laser microscopy probe for real-time in vivo molecular and morphological imaging of normal, inflammatory, and malignant tissue in rodents. In the rigid mini-microscopy probe (diameter 7 mm), a single line laser delivers an excitation wavelength of 488 nm. Optical slice thickness is 7 μm, lateral resolution 0.7 μm. The range of the z-axis is 0 - 250 μm below the tissue surface. Organ systems were examined in vivo in rodent models of human diseases. FITC-labeled Lycopersion esculentum lectin was injected or selected cell populations stained for molecular targeting. Morphological imaging was performed using fluorescein sodium, FITC-labeled d…
In vivo subsurface morphological and functional cellular and subcellular imaging of the gastrointestinal tract with confocal mini-microscopy.
AIM: To evaluate a newly developed hand-held confocal probe for in vivo microscopic imaging of the complete gastrointestinal tract in rodents. METHODS: A novel rigid confocal probe (diameter 7 mm) was designed with optical features similar to the flexible endomicroscopy system for use in humans using a 488 nm single line laser for fluorophore excitation. Light emission was detected at 505 to 750 nm. The field of view was 475 μm × 475 μm. Optical slice thickness was 7 μm with a lateral resolution of 0.7 μm. Subsurface serial images at different depths (surface to 250 μm) were generated in real time at 1024 × 1024 pixels (0.8 frames/s) by placing the probe onto the tissue in gentle, stable co…
In-vivo confocal real-time mini-microscopy in animal models of human inflammatory and neoplastic diseases
Background and study aims Although various improvements in tissue imaging modalities have recently been achieved, in-vivo molecular and subsurface imaging in the field of gastroenterology remains a technical challenge. In this study we evaluated a newly developed, handheld, miniaturized confocal laser microscopy probe for real-time in-vivo molecular and subsurface imaging in rodent models of human disease. Materials and methods The minimicroscope uses a 488-nm, single line laser for fluorophore excitation. The optical slice thickness is 7 microm, the lateral resolution 0.7 microm. The range of the z-axis is 0-250 microm below the tissue surface. Imaging was performed using different fluores…