In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis

2021

Background/purpose: The aim of the present in vitro study was to evaluate fatigue resistance of dental fixtures in three different types of fixture/abutment finishing line. Materials and methods: Transmucosal dental implants, with or without ferrulized neck, underwent fatigue tests (static and dynamic load) using the following standard protocol: UNI EN ISO 14801:2016. Two types of loading devices (screw- or cement-retained restoration) were also tested, and fatigue cycle tests were run to failure. Data of static and dynamic load tests were analyzed by proper statistical methods. Results: Following standard protocol for fatigue testing, the ILC type (Implant Level with ferrulized neck and ce…

OrthodonticsMaterials sciencemedicine.medical_treatmentFerruleDynamic load testingCrown (dentistry)lcsh:RK1-715Ferrulized implant necklcsh:DentistrymedicineFracture (geology)Ultimate failureOriginal ArticleImplantDeformation (engineering)Prosthesis fixationGeneral DentistryAbutment (dentistry)Fatigue testJournal of Dental Sciences
researchProduct

In-Vitro Investigation of Fatigue and Fracture Behavior of Transmucosal versus Submerged Bone Level Implants Used in Fixed Prosthesis

2021

Background: The present in vitro study aimed to investigate the fatigue performance of different dental fixtures in two different emergence profiles. Biological failures are frequently reported because the problem canonly be solved by replacing a failing implant with a new one. Clinicians addressed minor mechanical failures, such as bending, loosening or the fracture of screws, abutment, or the entire prosthesis, by simply replacing or fixing them. Methods: Transmucosal and submerged bone-level dental implants underwent fatigue strength tests (statical and dynamical performance) by a standardized test: UNI EN ISO 14801:2016. Two types of emergence profiles (Premium sub-crestal straight impl…

TechnologyQH301-705.5QC1-999medicine.medical_treatmentProsthesis03 medical and health sciences0302 clinical medicinemedicineimplant fractureUltimate failureGeneral Materials ScienceBiology (General)QD1-999InstrumentationMathematicsFluid Flow and Transfer ProcessesOrthodonticstransmucosal implantTPhysicsProcess Chemistry and TechnologyGeneral EngineeringNonparametric statistics030206 dentistryfatigue testEngineering (General). Civil engineering (General)Fatigue limitComputer Science ApplicationsChemistryCoronal planeFracture (geology)ImplantTA1-2040submerged bone-level implant neckAbutment (dentistry)030217 neurology & neurosurgeryApplied Sciences