Search for Effects Beyond the Born Approximation in Polarization Transfer Observables ine→pElastic Scattering
Intensive theoretical and experimental efforts over the past decade have aimed at explaining the discrepancy between data for the proton electric to magnetic form factor ratio, $$G_{E}/G_{M}$$, obtained separately from cross section and polarization transfer measurements. One possible explanation for this difference is a two-photon-exchange (TPEX) contribution. In an effort to search for effects beyond the one-photon-exchange or Born approximation, we report measurements of polarization transfer observables in the elastic $$H(\vec{e},e'\vec{p})$$ reaction for three different beam energies at a fixed squared momentum transfer $Q^2 = 2.5$ GeV$^2$, spanning a wide range of the virtual photon p…
Hard Two-Photon Contribution to Elastic Lepton-Proton Scattering Determined by the OLYMPUS Experiment
The OLYMPUS collaboration reports on a precision measurement of the positron-proton to electron-proton elastic cross section ratio, $R_{2\gamma}$, a direct measure of the contribution of hard two-photon exchange to the elastic cross section. In the OLYMPUS measurement, 2.01~GeV electron and positron beams were directed through a hydrogen gas target internal to the DORIS storage ring at DESY. A toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight scintillators detected elastically scattered leptons in coincidence with recoiling protons over a scattering angle range of $\approx 20\degree$ to $80\degree$. The relative luminosity between the two beam species was mo…
Familial recurrence of gastroschisis
Abstract Background Familial forms of gastroschisis are considered rare. A search for these forms in a population-based birth registry in 1993 found a recurrence risk of 3.5% among first-degree relatives. Since then, similar investigations in population-based registries have led to contradictory results. Methods A search of the population-based birth registry "Mainz Model" for familial cases of gastroschisis and a systematic review of the literature were performed. Results The Mainz Model database yielded 1 familial recurrence out of 27 gastroschisis cases. From the literature, 37 affected families could be retrieved. Among 412 gastroschises from population-based registries, 10 familial rec…
Spectroscopy of A=9 hyperlithium with the (e,e′K+) reaction
Hypernuclear Spectroscopy at JLab Hall C
Abstract Since the 1st generation experiment, E89-009, which was successfully carried out as a pilot experiment of (e,e'K+) hypernuclear spectroscopy at JLab Hall C in 2000, precision hypernuclear spectroscopy by the (e,e'K+) reactions made considerable progress. It has evolved to the 2nd generation experiment, E01-011, in which a newly constructed high resolution kaon spectrometer (HKS) was installed and the “Tilt method” was adopted in order to suppress large electromagnetic background and to run with high luminosity. Preliminary high-resolution spectra of 7 Λ He and 28 Λ Al together with that of 12 Λ B that achieved resolution better than 500 keV(FWHM) were obtained. The third generation…
High resolution spectroscopic study ofBeΛ10
Spectroscopy of a Be-10(Lambda) hypernucleus was carried out at JLab Hall C using the (e, e' K+) reaction. A new magnetic spectrometer system (SPL+ HES+ HKS), specifically designed for high resolution hypernuclear spectroscopy, was used to obtain an energy spectrum with a resolution of similar to 0.78 MeV (FWHM). The well-calibrated spectrometer system of the present experiment using p(e, e' K+)Lambda, Sigma(0) reactions allowed us to determine the energy levels; and the binding energy of the ground-state peak (mixture of 1(-) and 2(-) states) was found to be B-Lambda = 8.55 +/- 0.07(stat.) +/- 0.11(sys.) MeV. The result indicates that the ground-state energy is shallower than that of an em…
Detector response of Cherenkov radiators for calorimetry in the energy range below 14 MeV
Abstract A study of the detector response of PbF 2 crystals and three different types of lead glass blocks to electrons from a 14-MeV beam of the Mainz Microtron MAMI is presented. For the first time, signal height, signal width, and homogeneity of the response of these Cherenkov radiators were determined for energies between 10 and 14 MeV. To complement the beam tests, optical properties of the materials, in particular measured transmittances in the near UV and visible spectrum, were studied. The measured detector responses were also compared to Monte Carlo simulations of energy-loss, light production, transport, and detection. These Cherenkov radiators are considered as active material o…
Experiments with the High Resolution Kaon Spectrometer at JLab Hall C and the new spectroscopy ofΛ12Bhypernuclei
Since the pioneering experiment E89-009 studying hypernuclear spectroscopy using the (e, e’K+) reaction was completed, two additional experiments, E01-011 and E05-115, were performed at Jefferson Lab. These later experiments used a modified experimental design, the "tilt method", to dramatically suppress the large electromagnetic background, and allowed for a substantial increase in luminosity. Additionally, a new kaon spectrometer, HKS (E01-011), a new electron spectrometer, HES, and a new splitting magnet (E05-115) were added to produce new data sets of precision, high-resolution hypernuclear spectroscopy. All three experiments obtained a spectrum for 12B-Lambda, which is the most charact…
Spectroscopy of the neutron-rich hypernucleusHeΛ7from electron scattering
The missing mass spectroscopy of the HeΛ7 hypernucleus was performed using the Li7(e, e ′K+)HeΛ7 reaction at the Thomas Jefferson National Accelerator Facility Hall C. The Λ- binding energy of the ground-state (1/2+) was determined with a smaller error than that of the previous measurement, being BΛ=5.55±0.10stat.±0.11sys.MeV. The experiment also provided new insight into charge symmetry breaking in p-shell hypernuclear systems. Finally, a peak at BΛ=3.65±0.20stat. ±0.11sys.MeV was observed and assigned as a mixture of 3/2+ and 5/2+ states, confirming the "gluelike" behavior of Λ, which makes an unstable state in He6 stable against neutron emission.
Operation and characterization of a windowless gas jet target in high-intensity electron beams
Abstract A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with different target gases, e.g., hydrogen, deuterium , helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spectrometer facility at the electron accelerator MAMI. This paper focuses on the developed handling procedures and diagnostic tools, and on the performance of the gas jet target under beam conditions. Considering the special features of this type of target, it proves to be well suited for a n…
The OLYMPUS Experiment
Nuclear instruments & methods in physics research / A 741, 1 - 17 (2014). doi:10.1016/j.nima.2013.12.035
The BLAST experiment
The Bates large acceptance spectrometer toroid (BLAST) experiment was operated at the MIT-Bates Linear Accelerator Center from 2003 until 2005. The detector and experimental program were designed to study, in a systematic manner, the spin-dependent electromagnetic interaction in few-nucleon systems. As such the data will provide improved measurements for neutron, proton, and deuteron form factors. The data will also allow details of the reaction mechanism, such as the role of final state interactions, pion production, and resonances to be studied. The experiment used: a longitudinally polarized electron beam stored in the South Hall Storage Ring; a highly polarized, isotopically pure, inter…
Direct measurements of the lifetime of medium-heavy hypernuclei
Abstract The lifetime of a Λ particle embedded in a nucleus (hypernucleus) decreases from that of free Λ decay mainly due to the opening of the Λ N → N N weak decay channel. However, it is generally believed that the lifetime of a hypernucleus attains a constant value (saturation) for medium to heavy hypernuclear masses, yet this hypothesis has been difficult to verify. This paper presents a direct measurement of the lifetime of medium-heavy hypernuclei that were hyper-fragments produced by fission or break-up from heavy hypernuclei initially produced with a 2.34 GeV photon-beam incident on thin Fe, Cu, Ag, and Bi target foils. For each event, fragments were detected in coincident pairs by …
Neutral Pion Threshold Production atQ2=0.05GeV2/c2and Chiral Perturbation Theory
New data are presented on the $p({e,e}^{\ensuremath{'}}p){\ensuremath{\pi}}^{0}$ reaction at threshold at a four-momentum transfer of ${Q}^{2}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}0.05{\mathrm{GeV}}^{2}{/c}^{2}$. The data were taken with the three-spectrometer setup of the A1 Collaboration at the Mainz Microtron MAMI. The complete center of mass solid angle was covered up to a center of mass energy of 4 MeV above threshold. Combined with measurements at three different values of the virtual photon polarization $\ensuremath{\epsilon}$, the structure functions ${\ensuremath{\sigma}}_{T}$, ${\ensuremath{\sigma}}_{L}$, ${\ensuremath{\sigma}}_{\mathrm{TT}}$, and ${\ensuremath{\sigma…
Design and Operation of a Windowless Gas Target Internal to a Solenoidal Magnet for Use with a Megawatt Electron Beam
A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Lab's Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic…
High Resolution Λ Hypernuclear Spectroscopy with Electron Beams
T. Gogami1 ∗, P. Achenbach2, A. Ahmidouch3, I. Albayrak4, D. Androic5, A. Asaturyan6, R. Asaturyan6, O. Ates4, P. Baturin7, R. Badui7, W. Boeglin7, J. Bono7, E. Brash8, P. Carter8, C. Chen4, A. Chiba1, E. Christy4, S. Danagoulian3, R. De Leo10, D. Doi1, M. Elaasar11, R. Ent9, Y. Fujii1, M. Fujita1, M. Furic5, M. Gabrielyan7, L. Gan12, F. Garibaldi13, D. Gaskell9, A. Gasparian3, O. Hashimoto1, T. Horn9, B. Hu14, Ed. V. Hungerford21, M. Jones9, H. Kanda1, M. Kaneta1, S. Kato19, M. Kawai1, D. Kawama1, H. Khanal7, M. Kohl4, A. Liyanage4, W. Luo14, K. Maeda1, A. Margaryan6, P. Markowitz7, T. Maruta1, A. Matsumura1, V. Maxwell7, A. Mkrtchyan6, H. Mkrtchyan6, S. Nagao1, S. N. Nakamura1, A. Narayan…