0000000000073988

AUTHOR

F. Lattanzi

Vibrational spectra and force constants of symmetric tops

The infrared spectrum of H3SiI in the 800–1050 cm-1 region has been recorded with a resolution of 0·04 cm-1 and rotationally analysed. Features related to the Fermi resonance between v 5 and v 3 + v 6 and to the Coriolis x, y resonance between v 2 and v 5 have been explained, and a set of vibration-rotation parameters for the three bands has been determined by least-squares calculations, σ(J, K) = 9·4 × 10-3 cm-1. The Fermi resonance matrix element |W 356| is found to be 3·7859(7) cm-1 and the vibrational frequencies are v 2 0 = 904·551(1), v 5 0 = 941·0746(8) and (v 3 + v 6)0 = 953·688(3) cm-1. The anharmonicity constant, x 36 = -1·745(9) cm-1, has been determined. Comparison is made with …

research product

Angles de phases dans les éléments matriciels en spectroscopie ro-vibronique

research product

Rotational analysis of the v 2 + v 6 ±1, v 5 ∓1 + v 6 ∓1 and v 5 ∓1 + v 6 ±1 interacting infrared bands of methyl bromide

The rotational analysis of the infrared absorption spectrum of CH3 79Br and CH3 81Br between 2150 and 2510 cm-1 was performed on a Fourier transform spectrum with a resolution of 0·007 cm-1. The bands v 2 + v 6(E) and v 5 + v 6(A 1 + A 2 + E) occur in this region, giving rise to several perturbations as in the corresponding system of methyl chloride [3]. Forbidden transitions, observed in correspondence of the level crossing of the x-y Coriolis coupling between v 2 + v 6 and v 5 + v 6(E), enabled us to estimate the value of A″ - 225D″K at 5·16186 cm-1 for CH3 79Br and 5·16173 cm-1 for CH3 81Br. The parallel system of v 5 + v 6 exhibits a perpendicular structure, and an l-type resonance coup…

research product

Quality control of B-lines analysis in stress Echo 2020

Background The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each te…

research product