0000000000075624

AUTHOR

Gabriel Garcera

0000-0002-5507-4379

showing 3 related works from this author

Robust model-following control of parallel UPS single-phase inverters

2008

This paper presents a robust control technique applied to modular uninterruptible power-supply (UPS) inverters operating in parallel. When compared to conventional proportional-integral (PI) control, the proposed technique improves the response of the output voltage to load steps and to high distorted output currents, reducing the distortion of the output voltage. Furthermore, an excellent distribution of currents between modules is achieved, resulting in fine power equalization between the inverters on stream. The crossover frequency of the different loop gains involved is moderate, so that robustness to variations of the operation point and to modeling uncertainties is achieved. A compara…

Crossover frequencyEngineeringbusiness.industryInverter controlParallel invertersProportional controlModular designOperation pointUninterruptible power supply (UPS)TECNOLOGIA ELECTRONICAControl and Systems EngineeringControl theoryRobustness (computer science)Electronic engineeringElectrical and Electronic EngineeringRobust controlSingle phasebusinessVoltage
researchProduct

On the design of a high current power supply for superconducting magnet

2002

The purpose of the article is the description, considerations of design and presentation of experimental results of a high current (1000 A) and low voltage (up to 15 V) converter for the excitement of superconducting corrector magnets in particle accelerators. The power source, which is based on a ZVT converter, presents high efficiency, small output ripple, excellent regulation of line, and fulfilment of the EMC normative (VDE 0871 A).

InductanceEngineeringbusiness.industryMagnetRippleElectrical engineeringSuperconducting magnetbusinessInductorLow voltageCurrent transformerPower (physics)PESC Record. 27th Annual IEEE Power Electronics Specialists Conference
researchProduct

An Adaptive Robust Predictive Current Control for Three-Phase Grid-Connected Inverters

2011

This paper presents an adaptive robust predictive current control (RPCC) for grid-connected three-phase inverters that exhibit zero steady-state current error. The error correction is achieved by means of an adaptive strategy that works in parallel with the deadbeat algorithm, therefore preserving the typical fast response of the predictive law. The resulting control adapts to any particular L or LCL filter by estimation of the resistive part of the filter. As a variety of the RPCC class of control, it offers the best tradeoff between robustness and speed. © 2009 IEEE.

EngineeringAdaptive controlThree-phase inverterGrid connected invertersElectric current controlElectric invertersTECNOLOGIA ELECTRONICAControl theoryRobustness (computer science)Active power filteringCurrent-controlled voltage source invertersFast responseElectrical and Electronic EngineeringActive filterAdaptive strategyActive filtersActive power filtering (APF)Power convertersbusiness.industryGrid-connectedPredictive current controlGridSteady-state currentsDeadbeat algorithmModel predictive controlCurrent-controlled voltage source inverter (VSI)Robust predictive current control (RPCC)Three-phaseControl and Systems EngineeringRobust controlLCL filtersError detection and correctionbusinessIEEE Transactions on Industrial Electronics
researchProduct