0000000000076135

AUTHOR

Antonio Canals

0000-0001-7420-3976

showing 4 related works from this author

Ionic liquid-based single-drop microextraction followed by liquid chromatography-ultraviolet spectrophotometry detection to determine typical UV filt…

2009

Abstract A user-friendly and inexpensive ionic liquid-based single-drop microextraction (IL-SDME) procedure has been developed to preconcentrate trace amounts of six typical UV filters extensively used in cosmetic products (i.e., 2-hydroxy-4-methoxybenzophenone, isoamyl 4-methoxycinnamate, 3-(4′-methylbenzylidene)camphor, 2-ethylhexyl 2-cyano-3,3-diphenylacrylate, 2-ethylhexyl 4-dimethylaminobenzoate and 2-ethylhexyl 4-methoxycinnamate) from surface water samples prior to analysis by liquid chromatography-ultraviolet spectrophotometry detection (LC-UV). A two-stage multivariate optimization approach was developed by means of a Plackett–Burman design for screening and selecting the significa…

Detection limitAnalyteChromatographyCentral composite designmedicine.diagnostic_testAnalytical chemistryRepeatabilityAnalytical Chemistrychemistry.chemical_compoundchemistryIonic strengthSpectrophotometryIonic liquidmedicineSample preparationTalanta
researchProduct

Sensitive determination of free benzophenone-3 in human urine samples based on an ionic liquid as extractant phase in single-drop microextraction pri…

2007

Abstract Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has bee…

Detection limitChromatographyCentral composite designOrganic ChemistryAnalytical chemistryTemperatureIonic LiquidsGeneral MedicineBiochemistryHigh-performance liquid chromatographyChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryIonic strengthLiquid–liquid extractionStandard additionIonic liquidHumansSample preparationChromatography LiquidJournal of chromatography. A
researchProduct

Dispersive solid-phase extraction based on oleic acid-coated magnetic nanoparticles followed by gas chromatography-mass spectrometry for UV-filter de…

2011

Abstract A sensitive analytical method to concentrate and determine extensively used UV filters in cosmetic products at (ultra)trace levels in water samples is presented. The method is based on a sample treatment using dispersive solid-phase extraction (dSPE) with laboratory-made chemisorbed oleic acid-coated cobalt ferrite (CoFe 2 O 4 @oleic acid) magnetic nanoparticles (MNPs) as optimized sorbent for the target analytes. The variables involved in dSPE were studied and optimized in terms of sensitivity, and the optimum conditions were: mass of sorbent, 100 mg; donor phase volume, 75 mL; pH, 3; and sodium chloride concentration, 30% (w/v). After dSPE, the MNPs were eluted twice with 1.5 mL …

SorbentBiochemistrySensitivity and SpecificityGas Chromatography-Mass SpectrometryAnalytical ChemistryTap waterRiversSample preparationSolid phase extractionMagnetite NanoparticlesDetection limitChromatographyElutionChemistryOrganic ChemistryExtraction (chemistry)Osmolar ConcentrationSolid Phase ExtractionReproducibility of ResultsWaterGeneral MedicineHydrogen-Ion ConcentrationGas chromatography–mass spectrometrySunscreening AgentsWater Pollutants ChemicalOleic AcidJournal of chromatography. A
researchProduct

Simple and commercial readily-available approach for the direct use of ionic liquid-based single-drop microextraction prior to gas chromatography

2009

A simple and commercial readily-available approach that enables the direct use of ionic liquid (IL)-based single-drop microextraction (SDME) prior to gas chromatography (GC) is presented. The approach is based on thermal desorption (TD) of the analytes from the IL droplet to the GC system, by using a robust and commercially-available thermodesorption system. For this purpose, a two-glass-tube concentrically disposed system was designed. The inner tube is a laboratory-cut Pyrex tube (20mm length) that houses the ionic liquid droplet from the SDME process, and the outer tube is a commercially-available TD glass tube (187 mm length) commonly employed for stir-bar sorptive extractions (SBSE). I…

Detection limitChromatographyChemistryDrop (liquid)Organic ChemistryAnalytical chemistryThermal desorptionGeneral MedicineMass spectrometryBiochemistryAnalytical ChemistryTap waterSample preparationGas chromatographyGlass tubeJournal of Chromatography A
researchProduct