0000000000083474

AUTHOR

Javier Mir-mari

showing 4 related works from this author

Is measurement of the gingival biotype reliable? Agreement among different assessment methods.

2019

Background To determine agreement among the most commonly used methods for assessing the gingival biotype. Material and Methods An electronic survey was sent to a sample of dentists practicing in Spain. The questionnaire was based on the evaluation of 5 cases involving different gingival biotype assessment methods. Dentists were required to classify the cases as having a “thin”, “thick” or “not able to classify” biotype. Each case was assessed using a frontal intraoral photo of the anterior teeth; an enlarged photo of the buccal aspect of the tooth with a periodontal probe inserted inside the sulcus; and the real thickness measured in mm with a calibrated needle. Agreement among the classif…

ConcordanceGingivaPeriodontal probeOdontologia03 medical and health sciences0302 clinical medicineCohen's kappaIncisormedicineGeneral DentistryAnterior teethOrthodonticsbusiness.industryMalalties de les genivesResearch030206 dentistryPeriodontology:CIENCIAS MÉDICAS [UNESCO]Gum diseasesIncisormedicine.anatomical_structureOtorhinolaryngologySpainDentistryUNESCO::CIENCIAS MÉDICASGingival biotypePeriodonticsSurgerybusinessImplantologyKappaMedicina oral, patologia oral y cirugia bucal
researchProduct

Effect of bone loss on the fracture resistance of narrow dental implants after implantoplasty. An in vitro study

2021

Background Implantoplasty (IP) involves polishing of the exposed surface of implants affected by peri-implantitis (PI). A study was made to determine whether the degree of bone loss influences the fracture resistance of implants with or without IP. Material and Methods An in vitro study was carried out on 32 narrow (3.5 mm) dental implants with a rough surface and external hexagonal connection. Implantoplasty was performed in half of the implants of the sample. Both the IP and control implants were divided into two subgroups according to the amount of bone loss (3 mm or 7.5 mm). Standardized radiographic assessment of implant width was performed using specific software. The main outcome var…

ImplantoplastyMaterials scienceRadiographyAlveolar Bone LossCirurgia dentalDentistryCompressive strengthOutcome variableHumansIn vitro studycancerPeri-implantitisGeneral DentistryUNESCO:CIENCIAS MÉDICASTraumatismes dentalsTitaniumjaw boneDental traumaImplants dentalsHexagonal crystal systembusiness.industryResearchDental implantsTitaniOtorhinolaryngologyoral metastasesRough surfaceDental surgeryFracture (geology)incidenceSurgeryStress MechanicalImplantbusinesssoft tissueImplantology
researchProduct

Antibiotic prescription for the prevention and treatment of postoperative complications after routine dental implant placement. A cross-sectional stu…

2018

Background As there are no established guidelines for antibiotic prescription after dental implant placement a study was made to determine the current prescribing habits of several groups of practitioners regarding antibiotics to prevent and/or treat postoperative complications - early failures and infections - in relation to routine dental implant placement. Material and methods An electronic survey was sent to postgraduate students and professionals with experience in routine dental implant placement who practice in Spain. The questions asked were related to whether antibiotics were routinely prescribed either pre- or postoperatively to prevent and/or treat postoperative complications dur…

0301 basic medicineInfeccions quirúrgiquesCross-sectional studymedicine.drug_classmedicine.medical_treatmentSurgical wound infectionAntibioticsDentistryAntibiòtics01 natural sciencesOsseointegration03 medical and health sciencesAntibioticsPotassium ClavulanatemedicineDental implantGeneral DentistryImplants dentals010405 organic chemistrybusiness.industryResearchDental implantsAmoxicillin:CIENCIAS MÉDICAS [UNESCO]Confidence intervalAntibiotic prescription0104 chemical sciencesstomatognathic diseases030104 developmental biologyUNESCO::CIENCIAS MÉDICASOral Surgerybusinessmedicine.drug
researchProduct

Fracture resistance after implantoplasty in three implant-abutment connection designs

2020

Background To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results The mean wall thickness reductions varied between 106.46 and 153.75 µm. The me…

Dental Stress AnalysisTitanium implantMaterials scienceCirurgia dentalchemistry.chemical_elementDental Abutments03 medical and health sciences0302 clinical medicineFlexural strengthDental AbutmentsMaterials TestingGeneral DentistryEndosseous dental implantsDental ImplantsTitaniumOrthodonticsCrownsResearchConnection (principal bundle)030206 dentistry:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryDental surgeryUNESCO::CIENCIAS MÉDICASFracture (geology)SurgeryImplants dentals intraossisImplantImplantologyImplant abutmentTitanium
researchProduct