0000000000087708

AUTHOR

Till Neumann

showing 6 related works from this author

Everolimus eluting bioresorbable vascular scaffolds in patients with acute coronary syndromes: Two‐year results from the German‐Austrian ABSORB regis…

2021

Abstract Objectives To identify potential differences in 2‐year outcome between patients who underwent coronary revascularization using bioresorbable vascular scafffolds (BVS) in stable coronary artery disease (CAD) and acute coronary syndromes (ACS). Background Data from randomized trials suggest a significantly higher event rate following coronary revascularization using everolimus‐eluting BVS as compared to new generation drug eluting stents. Whether particular patient subgroups are at increased risk for scaffold thrombosis and target lesion failure (TLF) has not clearly been demonstrated. Methods German‐Austrian ABSORB RegIstRy is a prospective all‐comer multi‐center observational study…

Target lesionmedicine.medical_specialtyTime FactorsMedizinCoronary Artery Disease030204 cardiovascular system & hematologyProsthesis Designlaw.inventionCoronary artery disease03 medical and health sciencesPercutaneous Coronary Intervention0302 clinical medicineRandomized controlled triallawInternal medicineAbsorbable ImplantsmedicineHumansRadiology Nuclear Medicine and imagingIn patientEverolimusProspective StudiesRegistries030212 general & internal medicineddc:610Acute Coronary SyndromeEverolimusbusiness.industryGeneral Medicinemedicine.diseaseThrombosisStenosisTreatment OutcomeAustriaCardiologyCardiology and Cardiovascular MedicinebusinessMacemedicine.drug
researchProduct

P798Outcome of percutaneous coronary intervention with everolimus-eluting bioresorbable vascular scaffolds in patients with STEMI as compared to stab…

2018

medicine.medical_specialtyEverolimusbusiness.industrymedicine.medical_treatmentPercutaneous coronary interventionlanguage.human_languageGermanInternal medicineStable cadCardiologylanguageMedicineIn patientCardiology and Cardiovascular Medicinebusinessmedicine.drugEuropean Heart Journal
researchProduct

Evaluation of the short- and long-term safety and therapy outcomes of the everolimus-eluting bioresorbable vascular scaffold system in patients with …

2015

Abstract Background Third-generation drug-eluting metal stents are the gold standard for treatment of coronary artery disease. The permanent metallic caging of the vessel, however, can result in limited vasomotion, chronic inflammation, and late expansive remodeling, conditions that can lead to late and very late stent thrombosis. The development of bioresorbable scaffolds (BRSs) promises advantages over metal stents due to complete biodegradation within 2–4 years. Theoretically, since vessel scaffolding is temporary and no permanent implant remains in the vessel, BRSs, as opposed to metal stents, once degraded would no longer be potential triggers for stent-related adverse events or side e…

medicine.medical_specialtyPercutaneousmedicine.medical_treatmentMedizin030204 cardiovascular system & hematologyRevascularizationlaw.inventionCohort StudiesCoronary artery disease03 medical and health sciences0302 clinical medicineRandomized controlled triallawGermanyAbsorbable ImplantsmedicineHumansEverolimusProspective StudiesRegistries030212 general & internal medicineMyocardial infarctionEverolimusbusiness.industryCoronary StenosisPercutaneous coronary interventionDrug-Eluting StentsGeneral Medicinemedicine.diseaseSurgeryStenosisTreatment OutcomeResearch DesignAustriaCardiology and Cardiovascular Medicinebusinessmedicine.drugCardiovascular Revascularization Medicine
researchProduct

Predictors of scaffold failure and impact of optimized scaffold implantation technique on outcome: Results from the German-Austrian ABSORB RegIstRy.

2021

Aims We aimed to investigate predictors of scaffold failure and the potential impact of an optimized scaffold implantation technique by means of a learning curve on long-term clinical outcome after bioresorbable scaffold (BRS) implantation and to evaluate predictors of scaffold failure. Methods and results A total of 3326 patients were included in this prospective, observational, multi-center study (ClinicalTrials.gov NCT02066623) of consecutive patients undergoing BRS implantation between November 2013 and January 2016. The 3144 patients completed follow-up after 24 months, 3265 patients were eligible for time-to-event-analysis. Clinical endpoints were major adverse cardiac events-a compos…

Scaffoldmedicine.medical_specialtyTime FactorsTarget vessel revascularizationCoronary Artery Disease030204 cardiovascular system & hematologyProsthesis Design03 medical and health sciences0302 clinical medicinePercutaneous Coronary InterventionAbsorbable ImplantsmedicineClinical endpointHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineMyocardial infarctionProspective StudiesRegistriesbusiness.industryGeneral Medicinemedicine.diseaseThrombosisSurgeryTreatment OutcomeAustriaObservational studyCardiology and Cardiovascular MedicinebusinessBioresorbable scaffoldMaceCatheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventionsREFERENCES
researchProduct

Onset of heart failure determines the hepatic cell death pattern.

2011

Background and rationale. Acute and chronic heart failure (HF) may affect the liver, but the underlying mechanisms that lead to progressive liver damage are poorly understood. The hepatic cytokeratin-18 (CK18) epitopes M65 and M30 have been reported to distinguish between overall (necrotic) and apoptotic cell death, respectively. We aimed to evaluate the predominant hepatic cell death pattern in acute vs. chronic heart failure and examined if these assays predict the course of the disease. Main results. In a prospective study comprising 21 patients with acute HF (AHF) and 18 patients with chronic HF (CHF) serum levels of M65 and M30 were assessed. Compared with CHF, M65 levels were signific…

Cell deathMalemedicine.medical_specialtyProgrammed cell deathMedizinM65Specialties of internal medicineApoptosisLiver injuryEpitopesPredictive Value of TestsInternal medicinemedicineHumansProspective StudiesProspective cohort studySurvival analysisHeart FailureLiver injuryKeratin-18HepatologyCytokeratin 18business.industryM30Liver DiseasesGeneral MedicineMiddle AgedPrognosismedicine.diseaseSurvival AnalysisRC581-951LiverApoptosisPredictive value of testsHeart failureAcute DiseaseChronic DiseaseHepatic stellate cellCardiologyFemalebusinessBiomarkers
researchProduct

Hybrid Coronary Percutaneous Treatment with Metallic Stents and Everolimus-Eluting Bioresorbable Vascular Scaffolds: 2-years Results from the GABI-R …

2019

The limitations of the first-generation everolimus-eluting coronary bioresorbable vascular scaffolds (BVS) have been demonstrated in several randomized controlled trials. Little data are available regarding the outcomes of patients receiving hybrid stenting with both BVS and drug-eluting stents (DES). Of 3144 patients prospectively enrolled in the GABI-Registry, 435 (age 62 &plusmn

medicine.medical_specialtyPercutaneousmedicine.medical_treatmentMedizinlcsh:Medicine030204 cardiovascular system & hematologyKoronare HerzkrankheitRevascularizationAbsorbable implantsCoronary artery diseaseArticleCoronary artery diseasedrug eluting stents03 medical and health sciences0302 clinical medicineDrug-eluting StentMedizinische Fakultätstent bioresorbableMedicine030212 general & internal medicineMyocardial infarctionddc:610Drug-eluting stentsTissue scaffoldsEverolimusbusiness.industrylcsh:RStentGeneral Medicinemedicine.diseaseThrombosisSurgeryConventional PCIbusinessDDC 610 / Medicine & healthcoronary artery diseasemedicine.drugJournal of Clinical Medicine
researchProduct