0000000000091115

AUTHOR

Luccichenti G

Valutazione quantitativa tridimensionale del parenchima polmonare affetto da fibrosi cistica : risultati preliminari

Purpose. The aim of this study was to assess the feasibility of three-dimensional (3D) reconstructions and quantitative analysis of the volume of each component of the lung with cystic fibrosis (CF). Materials and methods. Twenty-two patients with CF (mean age 17±8 yeas) were included in the study. The patients underwent an unenhanced single-slice spiral computed tomography (CT) chest scan with the following parameters: collimation 3 mm, table feed 6 mm×rot-1, reconstruction interval 1 mm, soft tissue reconstruction kernel. Four image data sets were obtained: native axial slices, cine-mode display, virtual bronchographic volumerendered images with algorithm for tissue transition display and…

research product

Introduction to coronary imaging with 64-slice computed tomography

The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.

research product

Thoracic cardiovascular imaging with 16 row multislice computed tomography and retrospective ECG-gating.Technical note

research product

Non-invasive assessment of coronary artery stent patency with multislice CT: preliminary experience.

To evaluate the diagnostic accuracy of multislice computed tomography coronary angiography (MSCT-CA) in the detection of in-stent restenosis.Forty-two patients (33 male, 9 female, mean age 58+/-8 years) previously subjected to percutaneous implantation of coronary stent with suspected in-stent restenosis, underwent a 16-row MSCT (Sensation 16, Siemens) examination. The average time between stent implantation and MSCT-CA was 7.4+/-5.3 months. The following scan parameters were used: collimation 16x0.75 mm, rotation time 0.42 s, feed 3.0 mm/rot., kV 120, mAs 500. After administration of iodinated contrast material (Iomeprol 400 mgI/ml, 100 ml at 4 ml/s) and bolus chaser (40 ml of saline at 4 …

research product

Influenza dei filtri di convoluzione sulla misurazione dei valori di attenuazione della placca durante angiografia coronarica mediante TC multistrato

research product

Non-invasive evaluation of coronary calcium.

research product

Technical analysis of volume-rendering algorithms: application in low-contrast structures using liver vascularisation as a model.

research product

Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography

PURPOSE: To assess the variability in attenuation of coronary plaques with multislice CT-angiography (MSCT-CA) in an ex-vivo model with varying convolution kernels. MATERIALS AND METHODS: MSCT-CA (Sensation 16, Siemens) was performed in three ex-vivo left coronary arteries after instillation of contrast material solution (Iomeprol 400 mgI/ml, dilution: 1/80). The specimens were placed in oil to simulate epicardial fat. Scan parameters: slices 16/0.75 mm, rotation time 375 ms, feed/rotation 3.0 mm, mAs 500, slice thickness 1 mm, and FOV 50 mm. Datasets were reconstructed using 4 different kernels (B30f-smooth, B36f-medium smooth, B46f-medium, and B60f-sharp). Each scan was scored for the pre…

research product

Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice computed tomography coronary angiography.

PURPOSE: To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). MATERIALS AND METHODS: One hundred patients (88 males; 59+/-11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/ml at 4 ml/s and …

research product

Diagnostic accuracy of 16-row multislice CT angiography in the evaluation of coronary segments

research product