0000000000092561

AUTHOR

L. Piro

TES microcalorimeter for IXO: From focal plane to anticoincidence detector

The high resolution spectroscopy provides a unique technique to extract fundamental information in X-ray Astrophysics and Cosmology. In order to exploit at the best the capability of carrying out spectroscopy of faint sources, great care must be taken to reduce the background in the main detector. In this paper, we will present the working principle of a TES (Transition Edge Sensor) Microcalorimeter, its application for fine spectroscopy and a novel anticoincidence technique , based itself on a TES detector. Recent results from the first sample of the IXO-anticoincidence detector will be also shown.

research product

Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters

The employment of large arrays of microcalorimeters in space missions (IXO, EDGE/XENIA)[1][2][3], requires the presence of an anticoincidence detector to remove the background due to the particles, with a rejection efficiency at least equal to Suzaku (98%) [1]. A new concept of anticoincidence is under development to match the very tight thermal requirements and to simplify the design of the electronic chain. The idea is to produce a Cryo-AntiCoincidence (Cryo-AC) based on a silicon absorber and read by a TES (Transition-Edge Sensor). This configuration would ensure very good performances in terms of efficiency, time response and signal to noise ratio. We present the results of estimations,…

research product

Test of x-ray microcalorimeters with bilayer absorbers

Superconducting absorbers for thermal X-ray microcalorimeters should convert into thermalized phonons and transfer to the thermal sensor most of the energy deposited by single photons, on a time scale as short as a few tens of microseconds. Since deposition of X-ray energy in a superconductor produces quasiparticles by breaking up of Cooper pairs, the thermalization efficiency depends on the time scale on which they survive within the absorber volume, trapping part of the absorbed energy. According to the predicted values of their microscopic parameters, in many standard type-I superconducting metals the quasiparticle life time at very low temperatures results too long to allow for recombin…

research product

EDGE: explorer of diffuse emission and gamma-ray burst explosions

How structures on various scales formed and evolved from the early Universe up to present time is a fundamental question of astrophysical cosmology. EDGE will trace the cosmic history of the baryons from the early generations of massive star by Gamma-Ray Burst (GRB) explosions, through the period of cluster formation, down to very low redshifts, when between a third and one half of the baryons are expected to reside in cosmic filaments undergoing gravitational collapse by dark matter (Warm Hot Intragalactic Medium: WHIM). In addition EDGE, with its unprecedented observational capabilities, will provide key results on several other topics. The science is feasible with a medium class mission …

research product

The Cryogenic Anticoincidence Detector for ATHENA-XMS

The TES cryogenic detectors, due to their high spectral resolution and imaging capability in the soft X-ray domain, are the reference devices for the next proposed space missions whose aims are to characterize the spectra of faint or diffuse sources. ATHENA is the re-scoped IXO mission, and one of its focal plane instrument is the X-ray Microcalorimeter Spectrometer (XMS) working in the energy range 0.3-10 keV. XMS will be able to achieve the proposed scientific goals if a background lower than 0.02 cts/cm2/s/keV is guaranteed. The studies performed by GEANT4 simulations depict a scenario where it is mandatory to use an active Anti-Coincidence (AC) to reduce the expected background in the L…

research product

GRB 050904 at redshift 6.3: observations of the oldest cosmic explosion after the Big Bang

We present optical and near-infrared observations of the afterglow of the gamma-ray burst GRB 050904. We derive a photometric redshift z = 6.3, estimated from the presence of the Lyman break falling between the I and J filters. This is by far the most distant GRB known to date. Its isotropic-equivalent energy is 3.4x10^53 erg in the rest-frame 110-1100 keV energy band. Despite the high redshift, both the prompt and the afterglow emission are not peculiar with respect to other GRBs. We find a break in the J-band light curve at t_b = 2.6 +- 1.0 d (observer frame). If we assume this is the jet break, we derive a beaming-corrected energy E_gamma = (4-12)x10^51 erg. This limit shows that GRB 050…

research product

The focal plane assembly for the Athena X-ray Integral Field Unit instrument

This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a ~ 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off…

research product

The cryogenic anticoincidence detector for ATHENA-XMS: preliminary results from the new prototype

ATHENA has been the re-scoped IXO mission, and one of the foreseen focal plane instrument was the X-ray Microcalorimeter Spectrometer (XMS) working in the energy range 0.3-10 keV, which was a kilo-pixel array based on TES (Transition Edge Sensor) detectors. The need of an anticoincidence (AC) detector is legitimated by the results performed with GEANT4 simulations about the impact of the non x-ray background onto XMS at L2 orbit (REQ. < 0.02 cts/cm2/s/keV). Our consortium has both developed and tested several samples, with increasing area, in order to match the large area of the XMS (64 mm2). Here we show the preliminary results from the last prototype. The results achieved in this work off…

research product

The Athena X-ray Integral Field Unit (X-IFU)

著者人数: 23名

research product