0000000000092564
AUTHOR
L. Ferrari
TES microcalorimeter for IXO: From focal plane to anticoincidence detector
The high resolution spectroscopy provides a unique technique to extract fundamental information in X-ray Astrophysics and Cosmology. In order to exploit at the best the capability of carrying out spectroscopy of faint sources, great care must be taken to reduce the background in the main detector. In this paper, we will present the working principle of a TES (Transition Edge Sensor) Microcalorimeter, its application for fine spectroscopy and a novel anticoincidence technique , based itself on a TES detector. Recent results from the first sample of the IXO-anticoincidence detector will be also shown.
Zygomycosis in Italy: A survey of FIMUA-ECMM (Federazione Italiana di Micopatologia Umana ed Animale and European Confederation of Medical Mycology)
Abstract The aims of the study were to analyze the clinical and epidemiological characteristics and treatments for patients who developed zygomycosis enrolled in Italy during the European Confederation of Medical Mycology of medical mycology survey. This prospective multicenter study was performed between 2004 and 2007 at 49 italian Departments. 60 cases of zygomycosis were enrolled: the median age was 59.5 years (range 1-87), with a prevalence of males (70%). The majority of cases were immunocompromised patients (42 cases, 70%), mainly hematological malignancies (37). Among non-immunocompromised (18 cases, 30%), the main category was represented by patients with penetrating trauma (7/18, 3…
Study of Microcalorimeters for Astrophysics Applications
In the framework of the Italian Space Agency R&D project, which is focused on the development of microcalorimeters for applications on astrophysics, we are studying different methods for TES microcalorimeter production and developing simulations of various absorber performances. In this paper are presented preliminary results obtained with two different geometries: front back and planar on SiN membrane.
Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters
The employment of large arrays of microcalorimeters in space missions (IXO, EDGE/XENIA)[1][2][3], requires the presence of an anticoincidence detector to remove the background due to the particles, with a rejection efficiency at least equal to Suzaku (98%) [1]. A new concept of anticoincidence is under development to match the very tight thermal requirements and to simplify the design of the electronic chain. The idea is to produce a Cryo-AntiCoincidence (Cryo-AC) based on a silicon absorber and read by a TES (Transition-Edge Sensor). This configuration would ensure very good performances in terms of efficiency, time response and signal to noise ratio. We present the results of estimations,…
TH-302 + Gemcitabine (G + T) vs Gemcitabine (G) in Patients with Previously Untreated advanced Pancreatic Cancer (PAC)
ABSTRACT Background TH-302 is a hypoxia targeted prodrug with a hypoxia-triggered 2-nitroimidazole component designed to release the DNA alkylator, bromo-isophosphoramide mustard (Br-IPM), when reduced in severe hypoxia. A randomized Phase 2B study (NCT01144455) was conducted to assess the benefit of G + T to standard dose G as first-line therapy of PAC. Materials and methods An open-label multi-center study of two dose levels of TH-302 (240 mg/m2 or 340 mg/m2) in combination with G versus G alone (randomized 1:1:1). G (1000 mg/m2) and T were administered IV over 30-60 minutes on Days 1, 8 and 15 of a 28-day cycle. Patients on the G could crossover after progression and be randomized to a G…
Efficacy and safety of Everolimus and Exemestane in hormone-receptor positive (HR+) human-epidermal-growth-factor negative (HER2−) advanced breast cancer patients: New insights beyond clinical trials. The EVA study
Abstract Background The BOLERO-2 trial reported efficacy and safety of Everolimus (EVE) and Exemestane (EXE) combination in HR+ advanced breast cancer (ABC) patients. The BALLET trial further evaluated the safety of EVE-EXE in HR+ ABC patients, without reporting efficacy data. Aim of the EVA real-life study was to collect data of efficacy and safety of EVE-EXE combination in the clinical setting, as well as exploring efficacy according to EVE Dose-Intensity (DI) and to previous treatment with Fulvestrant. Patients and methods This study aimed to describe the outcome of ABC pts treated with EVE-EXE combination in terms of median duration of EVE treatment and ORR in a real-life setting. Resul…
Italian cancer figures, report 2014: Prevalence and cure of cancer in Italy
This Report intends to estimate the total number of people still alive in 2010 after cancer diagnosis in Italy, regardless of the time since diagnosis, and to project these estimates to 2015. This study is also aimed to estimate the number of already cured cancer patients, whose mortality rates have become undistinguishable from that of the general population of the same age and sex.The study took advantage of the information from the AIRTUM database, which included 29 Cancer Registries (covering 21 million people, 35% of the Italian population). A total of 1,624,533 cancer cases diagnosed between 1976 and 2009 contributed to the study. For each registry, the observed prevalence was calcula…
The TES-based cryogenic anticoincidence detector for IXO: First results from large area prototypes
The technique which combines high resolution spectroscopy with imaging capability is a powerful tool to extract fundamental information in X-ray Astrophysics and Cosmology. TES (Transition Edge Sensors)-based microcalorimeters match at best the requirements for doing fine spectroscopy and imaging of both bright (high count rate) and faint (poor signal-to-noise ratio) sources. For this reason they are considered among the most promising detectors for the next high energy space missions and are being developed for use on the focal plane of the IXO (International X-ray Observatory) mission. In order to achieve the required signal-to-noise ratio for faint or diffuse sources it is necessary to r…
ORIGIN: metal creation and evolution from the cosmic dawn
Herder, Jan-Willem den et al.