0000000000114056

AUTHOR

Ian Johnson

showing 4 related works from this author

A Demonstrator for a new Axial PET Concept

2008

In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…

PhysicsInterleavingInteraction pointPhysics::Instrumentation and Detectorsbusiness.industry3D reconstructionIterative reconstructionSTRIPSlaw.inventionCrystalOpticslawSensitivity (control systems)businessImage resolution2008 IEEE Nuclear Science Symposium Conference Record
researchProduct

Development of a High Precision Axial 3-D PET for Brain Imaging

2009

We describe a PET device based on a novel method to extract the coordinates of the interaction point of the 511keV γ rays from 100 mm long and thin LYSO (Lutetium Yttrium OxyorthoSilicate) scintillator bars, positioned axially in the tomograph. The coordinate along the hit crystal is measured by using a hodoscope of Wave Length Shifting (WLS) plastic strips mounted perpendicularly to each plane of scintillators. As photodetectors, new Geiger mode Avalanche PhotoDetectors (G-APDs) with integrated electronics are being used to detect both the hit crystal in a block (x and y coordinates) and the interaction point in the crystal (z coordinate) through the light escaping from the crystal and tra…

PhysicsSIMULATION TOOLKITCOORDINATENuclear and High Energy PhysicsInteraction pointPhysics::Instrumentation and Detectorsbusiness.industrySIMULATION TOOLKIT; PERFORMANCE; COORDINATE; DETECTOR; SCANNER; LENGTHPhotodetectorSTRIPSPERFORMANCEScintillatorAtomic and Molecular Physics and OpticsLyso-law.inventionCrystalSCANNEROpticsHodoscopelawLENGTHbusinessDETECTORImage resolutionNuclear Physics B - Proceedings Supplements
researchProduct

A New Scalable and Cost-Effective Congestion Management Strategy for Lossless Multistage Interconnection Networks

2005

In this paper, we propose a new congestion management strategy for lossless multistage interconnection networks that scales as network size and/or link bandwidth increase. Instead of eliminating congestion, our strategy avoids performance degradation beyond the saturation point by eliminating the HOL blocking produced by congestion trees. This is achieved in a scalable manner by using separate queues for congested flows. These are dynamically allocated only when congestion arises, and deallocated when congestion subsides. Performance evaluation results show that our strategy responds to congestion immediately and completely eliminates the performance degradation produced by HOL blocking whi…

Bandwidth managementQueueing theorybusiness.industryComputer scienceDistributed computingComputerSystemsOrganization_COMPUTER-COMMUNICATIONNETWORKSMultistage interconnection networksBlocking (statistics)Network traffic controlNetwork congestionScalabilityBandwidth (computing)businessComputer network11th International Symposium on High-Performance Computer Architecture
researchProduct

AX-PET: A novel PET detector concept with full 3D reconstruction

2009

We describe the concept and first experimental tests of a novel 3D axial Positron Emission Tomography (PET) geometry. It allows for a new way of measuring the interaction point in the detector with very high precision. It is based on a matrix of long Lutetium-Yttrium OxyorthoSilicate (LYSO) crystals oriented in the axial direction, each coupled to one Geiger Mode Avalanche Photodiode (G-APD) array. To derive the axial coordinate, Wave Length Shifter (WLS) strips are mounted orthogonally and interleaved between the crystals. The light from the WLS strips is read by custom-made G-APDs. The weighted mean of the signals in the WLS strips has proven to give very precise axial resolution. The ach…

SIMULATION TOOLKIT; COORDINATE; LENGTHNuclear and High Energy PhysicsSIMULATION TOOLKITCOORDINATEImage qualityPhysics::Instrumentation and DetectorsPhysics::Medical PhysicsLYSOSTRIPSLyso-law.inventionMatrix (mathematics)WLSOpticslawLENGTHInstrumentationPhysicsInteraction pointbusiness.industry3D reconstructionDetectorG-APDPETParallaxbusinessPositron Emission Tomography
researchProduct