A Demonstrator for a new Axial PET Concept

In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…

research product

High performance detector head for PET and PET/MR with continuous crystals and SiPMs

International audience; A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm source continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of 22Na sources. An image reconstruction method specifically adapted for continuous crystals has been emp…

research product

Neutrino masses from operator mixing

We show that in theories that reduce, at the Fermi scale, to an extension of the standard model with two doublets, there can be additional dimension five operators giving rise to neutrino masses. In particular there exists a singlet operator which can not generate neutrino masses at tree level but generates them through operator mixing. Under the assumption that only this operator appears at tree level we calculate the neutrino mass matrix. It has the Zee mass matrix structure and leads naturally to bimaximal mixing. However, the maximal mixing prediction for solar neutrinos is very sharp even when higher order corrections are considered. To allow for deviations from maximal mixing a fine t…

research product

The AX-PET demonstrator—Design, construction and characterization

Abstract Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end …

research product

Performance of the AX-PET Demonstrator

The goal of the AX-PET project is to build and test a demonstrator for a high resolution, high sensitivity PET scanner, based on a novel geometrical concept of long axially oriented crystals. The demonstrator comprises two PET modules used in coincidence. The two modules have been constructed and characterized (both individually and in coincidence) in dedicated test setups, with point-like sources. Good performance in terms of energy, spatial and timing resolution have been demonstrated. First measurements with extended phantoms filled with FDG-radiotracers have been recently performed.

research product

Universal extra dimensions andZ→bb¯

We study, at the one loop level, the dominant contributions from a single universal extra dimension to the process $\stackrel{\ensuremath{\rightarrow}}{Z}b\overline{b}.$ By resorting to the gaugeless limit of the theory we explain why the result is expected to display a strong dependence on the mass of the top quark, not identified in the early literature. A detailed calculation corroborates this expectation, giving rise to a lower bound for the compactification scale which is comparable to that obtained from the $\ensuremath{\rho}$ parameter. An estimate of the subleading corrections is furnished, together with a qualitative discussion on the difference between the present results and thos…

research product

Prospects for the Zee-Babu Model at the LHC and low energy experiments

We analyze the viability of the Zee-Babu model as an explanation of observed neutrino masses and mixings and the possibility that the model is confirmed or discarded in experiments planned for the very close future. The allowed parameter space is studied analytically by using some approximations and partial data. Then, a complete scanning of all parameters and constraints is performed numerically by using Monte Carlo methods. The cleanest signal of the model will be the detection of the doubly charged scalar at the LHC and its correlation with measurements of the branching ratio of $\mu\to e\gamma$ at the MEG experiment. In addition, the model offers interesting predictions for $\tau^{-}\to…

research product

Development of a High Precision Axial 3-D PET for Brain Imaging

We describe a PET device based on a novel method to extract the coordinates of the interaction point of the 511keV γ rays from 100 mm long and thin LYSO (Lutetium Yttrium OxyorthoSilicate) scintillator bars, positioned axially in the tomograph. The coordinate along the hit crystal is measured by using a hodoscope of Wave Length Shifting (WLS) plastic strips mounted perpendicularly to each plane of scintillators. As photodetectors, new Geiger mode Avalanche PhotoDetectors (G-APDs) with integrated electronics are being used to detect both the hit crystal in a block (x and y coordinates) and the interaction point in the crystal (z coordinate) through the light escaping from the crystal and tra…

research product

AX-PET: Concept, proof of principle and first results with phantoms

AX-PET is a novel PET concept based on long crystals axially arranged and orthogonal Wavelength shifter (WLS) strips, both individually readout by Geiger-mode Avalanche Photo Diodes (G-APD). Its design was conceived in order to reduce the parallax error and simultaneously improve spatial resolution and sensitivity. The assessment of the AX-PET concept and potential was carried out through a set of measurements comprising individual module characterizations and scans in coincidence mode of point-like and extended sources. The estimated energy and spatial resolutions from point-like measurements are R FWHM =11.6% (at 511 keV) and 1.7–1.9 mm (FWHM) respectively as measured with point-like sour…

research product

Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events

The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events will attempt to determine which of the possible candidate lines of response (LoRs) correctly determine the annihilation photon trajectory. However, methods of assessment often have low su…

research product

The AX-PET Concept: New Developments And Tomographic Imaging

The Axial PET (AX-PET) concept proposes a novel detection geometry for PET, based on layers of long scintillating crystals axially aligned with the bore axis. Arrays of wavelength shifting (WLS) strips are placed orthogonally and underneath the crystal layers; both crystals and strips are individually readout by G-APDs. The axial coordinate is obtained from the WLS signals by means of a Center-of-Gravity method combined with a cluster algorithm. This design allows spatial resolution and sensitivity to be decoupled and thus simultaneously optimized. In this work we present the latest results obtained with the 2-module AX-PET scanner prototype, which consists of 6 radial layers of 8 LYSO crys…

research product

Can power corrections be reliably computed in models with extra dimensions?

We critically revisit the issue of power-law running in models with extra dimensions. The analysis is carried out in the context of a higher-dimensional extension of QED, with the extra dimensions compactified on a torus. It is shown that a naive $\beta$ function, which simply counts the number of modes, depends crucially on the way the thresholds of the Kaluza-Klein modes are crossed. To solve these ambiguities we turn to the vacuum polarization, which, due to its special unitarity properties, guarantees the physical decoupling of the heavy modes. This latter quantity, calculated in the context of dimensional regularization, is used for connecting the low energy gauge coupling with the cou…

research product

Inclusion of Inter Crystal Scatter data in PET

In PET, as the spatial resolution of the measurement system is increased, multiple interactions of a single photon may be separately measured and such events are often removed from the data used in image reconstruction. While for some PET imaging tasks this effect is unimportant, for primate, brain and high-spatial-resolution imaging where sensitivity is important, such Inter Crystal Scattering (ICS) events may constitute a large fraction of the measured data. On-the-fly list-mode image reconstruction is generally required in order to use all the information provided by ICS. Simulated One-Pass List-mode image reconstruction is used in this investigation to study the inclusion of ICS informa…

research product

Power corrections in models with extra dimensions

We critically revisit the issue of power-law running in models with extra dimensions. The general conclusion is that, in the absence of any additional physical principle, the power-corrections tend to depend strongly on the details of the underlying theory.

research product

Simulated one-pass list-mode: an approach to on-the-fly system matrix calculation.

In the development of prototype systems for positron emission tomography a valid and robust image reconstruction algorithm is required. However, prototypes often employ novel detector and system geometries which may change rapidly under optimization. In addition, developing systems generally produce highly granular, or possibly continuous detection domains which require some level of on-the-fly calculation for retention of measurement precision. In this investigation a new method of on-the-fly system matrix calculation is proposed that provides advantages in application to such list-mode systems in terms of flexibility in system modeling. The new method is easily adaptable to complicated sy…

research product

A Monte-Carlo based model of the AX-PET demonstrator and its experimental validation

AX-PET is a novel PET detector based on axially oriented crystals and orthogonal wavelength shifter (WLS) strips, both individually read out by silicon photo-multipliers. Its design decouples sensitivity and spatial resolution, by reducing the parallax error due to the layered arrangement of the crystals. Additionally the granularity of AX-PET enhances the capability to track photons within the detector yielding a large fraction of inter-crystal scatter events. These events, if properly processed, can be included in the reconstruction stage further increasing the sensitivity. Its unique features require dedicated Monte-Carlo simulations, enabling the development of the device, interpreting …

research product

AX-PET: A novel PET detector concept with full 3D reconstruction

We describe the concept and first experimental tests of a novel 3D axial Positron Emission Tomography (PET) geometry. It allows for a new way of measuring the interaction point in the detector with very high precision. It is based on a matrix of long Lutetium-Yttrium OxyorthoSilicate (LYSO) crystals oriented in the axial direction, each coupled to one Geiger Mode Avalanche Photodiode (G-APD) array. To derive the axial coordinate, Wave Length Shifter (WLS) strips are mounted orthogonally and interleaved between the crystals. The light from the WLS strips is read by custom-made G-APDs. The weighted mean of the signals in the WLS strips has proven to give very precise axial resolution. The ach…

research product

Bounds on models with one latticized extra dimension

We study an extension of the standard model with one latticized extra dimension accessible to all fields. The model is characterized by the size of the extra dimension and the number of sites, and contains a tower of massive particles. At energies lower than the mass of the new particles there are no tree-level effects. Therefore, bounds on the scale of new physics can only be set from one-loop processes. We calculate several observables sensitive to loop-effects, such as the $\rho$ parameter, $b\to s \gamma$, $Z\to b\bar b$, and the $B^0\rightleftharpoons\bar{B}^0$ mixing, and use them to set limits on the lightest new particles for different number of sites. It turns out that the continuo…

research product

Long axial crystals for PET applications: The AX-PET demonstrator and beyond

The usage of long, axially oriented scintillator crystals in a PET scanner has been shown by the AX-PET Demonstrator as a possible solution for a high resolution and high sensitivity PET detector. In the AX-PET implementation, arrays of wavelength shifting (WLS) strips, placed orthogonally behind every crystal layer, are used to define the axial coordinate. After extensive characterization measurements, the AX-PET Demonstrator has been successfully used for the reconstruction of several phantoms and a few rodents. Possible extensions of the AX-PET concept towards Time Of Flight capabilities have been investigated, using Philips digital SiPMs as alternative photodetector. Promising CRT value…

research product

AX-PET: A novel PET concept with G-APD readout

Abstract The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 keV and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS s…

research product