0000000000114065

AUTHOR

E. Chesi

showing 19 related works from this author

A Demonstrator for a new Axial PET Concept

2008

In PET imaging, improving sensitivity while maintaining very good spatial resolution is crucial. To achieve this goal, we propose a novel concept of PET scanner, with axially arranged crystals, providing a high sensitivity and a 3D reconstruction of the gamma interaction point. The trans-axial coordinate is given by the crystal hit, while the z coordinate is reconstructed by the weighted distribution of light escaping the crystal and entering into an array of Wave Length Shifting (WLS) strips interleaving the crystal layers. This novel configuration allows full identification of Compton interactions in the crystals that can be included in image reconstruction thus enhancing the sensitivity.…

PhysicsInterleavingInteraction pointPhysics::Instrumentation and Detectorsbusiness.industry3D reconstructionIterative reconstructionSTRIPSlaw.inventionCrystalOpticslawSensitivity (control systems)businessImage resolution2008 IEEE Nuclear Science Symposium Conference Record
researchProduct

The AX-PET demonstrator—Design, construction and characterization

2011

Abstract Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end …

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and Detectorsbusiness.industryPhysics::Medical PhysicsDetectorPhase (waves)STRIPSLyso-law.inventionSilicon photomultiplierData acquisitionOpticsCardinal pointpet; axial geometry; brain; scanner; sipm; detector; geiger-mode avalanche photo diodes (g-apd)lawbusinessInstrumentationDiodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A prototype of very high resolution small animal PET scanner using silicon pad detectors

2007

Abstract A very high-resolution small animal positron emission tomograph (PET), which can achieve sub-millimeter spatial resolution, is being developed using silicon pad detectors. The prototype PET for a single slice instrument consists of two 1 mm thick silicon pad detectors, each containing a 32×16 array of 1.4×1.4 mm pads readout with four VATAGP3 chips which have 128 channels low-noise self-triggering ASIC in each chip, coincidence units, a source turntable and tungsten slice collimator. The silicon detectors were located edgewise on opposite sides of a 4 cm field-of-view to maximize efficiency. Energy resolution is dominated by electronic noise, which is 0.98% (1.38 keV) FWHM at 140.5…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtySiliconbusiness.industryDetectorResolution (electron density)chemistry.chemical_elementCollimatorChipLine sourceArticlelaw.inventionOpticschemistrylawmedicineWaferMedical physicsbusinessInstrumentationImage resolution
researchProduct

Silicon as an Unconventional Detector in Positron Emission Tomography.

2012

Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been a successful in achieving ~5mm FWHM spatial resolution in human studies and ~1mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches. Foremost is it…

PhysicsNuclear and High Energy Physics010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsDetectorPhysics::Medical PhysicsPhotodetectorScintillator01 natural sciencesParticle detectorLyso-Article030218 nuclear medicine & medical imagingSemiconductor detector03 medical and health sciences0302 clinical medicineOptics0103 physical sciencesMedical imagingbusinessInstrumentationImage resolutionNuclear instrumentsmethods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
researchProduct

Performance of the AX-PET Demonstrator

2011

The goal of the AX-PET project is to build and test a demonstrator for a high resolution, high sensitivity PET scanner, based on a novel geometrical concept of long axially oriented crystals. The demonstrator comprises two PET modules used in coincidence. The two modules have been constructed and characterized (both individually and in coincidence) in dedicated test setups, with point-like sources. Good performance in terms of energy, spatial and timing resolution have been demonstrated. First measurements with extended phantoms filled with FDG-radiotracers have been recently performed.

Nuclear and High Energy PhysicsEngineeringbusiness.industryPet scannerResolution (electron density)Sensitivity (control systems)businessAtomic and Molecular Physics and OpticsEnergy (signal processing)CoincidenceSimulation
researchProduct

A device to measure the effects of strong magnetic fields on the image resolution of PET scanners

2009

Abstract Very high resolution images can be achieved in small animal PET systems utilizing solid state silicon pad detectors. As these systems approach sub-millimeter resolutions, the range of the positron is becoming the dominant contribution to image blur. The size of the positron range effect depends on the initial positron energy and hence the radioactive tracer used. For higher energy positron emitters, such as Ga 68 and Tc 94 m , which are gaining importance in small animal studies, the width of the annihilation point distribution dominates the spatial resolution. This positron range effect can be reduced by embedding the field of view of the PET scanner in a strong magnetic field. In…

PhysicsNuclear and High Energy PhysicsRadioactive tracerAnnihilationPhysics::Instrumentation and Detectorsbusiness.industryResolution (electron density)DetectorField of viewlaw.inventionMagnetic fieldOpticsNuclear magnetic resonancePositronlawPhysics::Accelerator PhysicsbusinessInstrumentationImage resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Development of a High Precision Axial 3-D PET for Brain Imaging

2009

We describe a PET device based on a novel method to extract the coordinates of the interaction point of the 511keV γ rays from 100 mm long and thin LYSO (Lutetium Yttrium OxyorthoSilicate) scintillator bars, positioned axially in the tomograph. The coordinate along the hit crystal is measured by using a hodoscope of Wave Length Shifting (WLS) plastic strips mounted perpendicularly to each plane of scintillators. As photodetectors, new Geiger mode Avalanche PhotoDetectors (G-APDs) with integrated electronics are being used to detect both the hit crystal in a block (x and y coordinates) and the interaction point in the crystal (z coordinate) through the light escaping from the crystal and tra…

PhysicsSIMULATION TOOLKITCOORDINATENuclear and High Energy PhysicsInteraction pointPhysics::Instrumentation and Detectorsbusiness.industrySIMULATION TOOLKIT; PERFORMANCE; COORDINATE; DETECTOR; SCANNER; LENGTHPhotodetectorSTRIPSPERFORMANCEScintillatorAtomic and Molecular Physics and OpticsLyso-law.inventionCrystalSCANNEROpticsHodoscopelawLENGTHbusinessDETECTORImage resolutionNuclear Physics B - Proceedings Supplements
researchProduct

AX-PET: Concept, proof of principle and first results with phantoms

2010

AX-PET is a novel PET concept based on long crystals axially arranged and orthogonal Wavelength shifter (WLS) strips, both individually readout by Geiger-mode Avalanche Photo Diodes (G-APD). Its design was conceived in order to reduce the parallax error and simultaneously improve spatial resolution and sensitivity. The assessment of the AX-PET concept and potential was carried out through a set of measurements comprising individual module characterizations and scans in coincidence mode of point-like and extended sources. The estimated energy and spatial resolutions from point-like measurements are R FWHM =11.6% (at 511 keV) and 1.7–1.9 mm (FWHM) respectively as measured with point-like sour…

Coincidence modePhysicsbusiness.industryExtended sourcesSTRIPSIterative reconstructionConcept-basedWavelength shifterAvalanche photodiodeCoincidencelaw.inventionOpticslawCoincidence mode; Concept-based; Extended sourcesbusinessParallaxImage resolutionDiodeIEEE Nuclear Science Symposuim & Medical Imaging Conference
researchProduct

A Pixelated Silicon Positron Sensitive Imaging Probe

2006

A pixelated silicon positron sensitive imaging probe is under development to precisely localize superficially located tumors accumulating 18F-FDG. 18F-FDG has been a radioisotope of interest mainly because of the high uptake in tumors and the relatively short positron range. Silicon detectors have generally low detection efficiency for high energy photons and can be used for positron detection. We present a pixelated silicon positron sensitive imaging probe that has the 1.4-by-1.4-by-1.0 mm pixel size with equivalent electronic noise of ~1.2 keV FWHM. The small pixel size leads to the high spatial resolution. Probe movement in conjunction with appropriate reconstruction will allow sub-pixel…

PhysicsPixelSiliconPhysics::Instrumentation and Detectorsbusiness.industryDetectorMonte Carlo methodResolution (electron density)chemistry.chemical_elementIterative reconstructionOpticsPositronchemistrybusinessNuclear medicineImage resolutionIEEE Nuclear Science Symposium Conference Record, 2005
researchProduct

First coincidences in pre-clinical Compton camera prototype for medical imaging

2003

Abstract Compton collimated imaging may improve the detection of gamma rays emitted by radioisotopes used in single photon emission computed tomography (SPECT). We present a crude prototype consisting of a single 500 μm thick, 256 pad silicon detector with pad size of 1.4×1.4 mm 2 , combined with a 15×15×1 cm 3 NaI scintillator crystal coupled to a set of 20 photo multipliers. Emphasis is placed on the performance of the silicon detector and the associated read-out electronics, which has so far proved to be the most challenging part of the set-up. Results were obtained using the VATAGP3, 128 channel low-noise self-triggering ASIC as the silicon detector's front-end. The noise distribution (…

PhysicsSingle photon emission computed tomography (SPECT)Nuclear and High Energy PhysicsPhotonbusiness.industryPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaGamma rayCompton scatteringScintillatorCollimated lightFull width at half maximum87.58.Ce; 29.40.GxOpticsSilicon pad detectorsCoincidentTracking and position-sensitive detectorsMedical imaging[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]businessInstrumentationNoise (radio)Compton camera
researchProduct

Performance evaluation of a very high resolution small animal PET imager using silicon scatter detectors

2007

A very high resolution positron emission tomography (PET) scanner for small animal imaging based on the idea of inserting a ring of high-granularity solid-state detectors into a conventional PET scanner is under investigation. A particularly interesting configuration of this concept, which takes the form of a degenerate Compton camera, is shown capable of providing sub-millimeter resolution with good sensitivity. We present a Compton PET system and estimate its performance using a proof-of-concept prototype. A prototype single-slice imaging instrument was constructed with two silicon detectors 1 mm thick, each having 512 1.4 mm x 1.4 mm pads arranged in a 32 x 16 array. The silicon detector…

PhysicsSiliconScannerPhotonRadiological and Ultrasound TechnologySiliconbusiness.industryDetectorResolution (electron density)chemistry.chemical_elementEquipment DesignFull width at half maximumOpticschemistryPositron-Emission TomographyAnimalsRadiology Nuclear Medicine and imagingbusinessSensitivity (electronics)Image resolutionPhysics in Medicine and Biology
researchProduct

The AX-PET Concept: New Developments And Tomographic Imaging

2011

The Axial PET (AX-PET) concept proposes a novel detection geometry for PET, based on layers of long scintillating crystals axially aligned with the bore axis. Arrays of wavelength shifting (WLS) strips are placed orthogonally and underneath the crystal layers; both crystals and strips are individually readout by G-APDs. The axial coordinate is obtained from the WLS signals by means of a Center-of-Gravity method combined with a cluster algorithm. This design allows spatial resolution and sensitivity to be decoupled and thus simultaneously optimized. In this work we present the latest results obtained with the 2-module AX-PET scanner prototype, which consists of 6 radial layers of 8 LYSO crys…

PhysicsScannerTomographic reconstructionbusiness.industrySTRIPSIterative reconstructionImaging phantomLyso-law.inventionOpticsData acquisitionlawcount ratebusinessImage resolution
researchProduct

Advances in Technology for High-Energy Subnuclear Physics. Contribution of the LAA Project.

1990

PhysicsHigh energy[PHYS.HEXP] Physics [physics]/High Energy Physics - Experiment [hep-ex]010308 nuclear & particles physics0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]General Physics and Astronomy010306 general physics01 natural sciencesEngineering physics
researchProduct

Timing performance of the silicon PET insert probe

2010

Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 2…

SiliconMaterials scienceSiliconPhysics::Instrumentation and DetectorsTransducerschemistry.chemical_elementIntegrated circuitScintillatorTracking (particle physics)Sensitivity and Specificity01 natural sciencesLyso-030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineOpticslaw0103 physical sciencesRadiology Nuclear Medicine and imagingDiodeRadiationCt Spect/Ct Pet/CtRadiological and Ultrasound Technology010308 nuclear & particles physicsbusiness.industryDetectorPublic Health Environmental and Occupational HealthReproducibility of ResultsEquipment DesignGeneral MedicineImage EnhancementEquipment Failure AnalysisTransducerchemistryPositron-Emission TomographybusinessRadiation Protection Dosimetry
researchProduct

A high-resolution PET demonstrator using a silicon "magnifying glass".

2021

Abstract To assist ongoing investigations of the limits of the tradeoff between spatial resolution and noise in PET imaging, several PET instruments based on silicon-pad detectors have been developed. The latest is a segment of a dual-ring device to demonstrate that excellent reconstructed image resolution can be achieved with a scanner that uses highresolution detectors placed close to the object of interest or surrounding a small field-of-view in combination with detectors having modest resolution at larger radius. The outer ring of our demonstrator comprises conventional BGO block detectors scavenged from a clinical PET scanner and located at a 500 mm radius around a 50 mm diameter field…

ScannerPhotonSiliconchemistry.chemical_elementScintillatorPhysics and Astronomy(all)01 natural sciencesArticle030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticssilicon detectors0103 physical sciencesDetectors and Experimental Techniquesmagnifying PETImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorResolution (electron density)high-resolution imagingRadiusPETchemistrybusinessPhysics procedia
researchProduct

A Monte-Carlo based model of the AX-PET demonstrator and its experimental validation

2013

AX-PET is a novel PET detector based on axially oriented crystals and orthogonal wavelength shifter (WLS) strips, both individually read out by silicon photo-multipliers. Its design decouples sensitivity and spatial resolution, by reducing the parallax error due to the layered arrangement of the crystals. Additionally the granularity of AX-PET enhances the capability to track photons within the detector yielding a large fraction of inter-crystal scatter events. These events, if properly processed, can be included in the reconstruction stage further increasing the sensitivity. Its unique features require dedicated Monte-Carlo simulations, enabling the development of the device, interpreting …

PhotonRadiological and Ultrasound TechnologyPhysics::Instrumentation and Detectors010308 nuclear & particles physicsComputer scienceDetectorMonte Carlo methodWavelength shifter01 natural sciences030218 nuclear medicine & medical imagingComputational science03 medical and health sciences0302 clinical medicinePositron-Emission Tomography0103 physical sciencesRadiology Nuclear Medicine and imagingSensitivity (control systems)ParallaxMonte Carlo MethodImage resolutionSimulationPhysics in Medicine and Biology
researchProduct

AX-PET: A novel PET detector concept with full 3D reconstruction

2009

We describe the concept and first experimental tests of a novel 3D axial Positron Emission Tomography (PET) geometry. It allows for a new way of measuring the interaction point in the detector with very high precision. It is based on a matrix of long Lutetium-Yttrium OxyorthoSilicate (LYSO) crystals oriented in the axial direction, each coupled to one Geiger Mode Avalanche Photodiode (G-APD) array. To derive the axial coordinate, Wave Length Shifter (WLS) strips are mounted orthogonally and interleaved between the crystals. The light from the WLS strips is read by custom-made G-APDs. The weighted mean of the signals in the WLS strips has proven to give very precise axial resolution. The ach…

SIMULATION TOOLKIT; COORDINATE; LENGTHNuclear and High Energy PhysicsSIMULATION TOOLKITCOORDINATEImage qualityPhysics::Instrumentation and DetectorsPhysics::Medical PhysicsLYSOSTRIPSLyso-law.inventionMatrix (mathematics)WLSOpticslawLENGTHInstrumentationPhysicsInteraction pointbusiness.industry3D reconstructionDetectorG-APDPETParallaxbusinessPositron Emission Tomography
researchProduct

Long axial crystals for PET applications: The AX-PET demonstrator and beyond

2013

The usage of long, axially oriented scintillator crystals in a PET scanner has been shown by the AX-PET Demonstrator as a possible solution for a high resolution and high sensitivity PET detector. In the AX-PET implementation, arrays of wavelength shifting (WLS) strips, placed orthogonally behind every crystal layer, are used to define the axial coordinate. After extensive characterization measurements, the AX-PET Demonstrator has been successfully used for the reconstruction of several phantoms and a few rodents. Possible extensions of the AX-PET concept towards Time Of Flight capabilities have been investigated, using Philips digital SiPMs as alternative photodetector. Promising CRT value…

Materials sciencebusiness.industryDetectorPhotodetectorSTRIPSIterative reconstructionScintillatorlaw.inventionTime of flightOpticslawbusinessAxial symmetryImage resolution2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)
researchProduct

AX-PET: A novel PET concept with G-APD readout

2012

Abstract The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 keV and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS s…

PhysicsNuclear and High Energy PhysicsPhotonPhysics::Instrumentation and Detectorsbusiness.industryPhysics::Medical PhysicsDetectorCompton scatteringField of viewLyso-030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplier030220 oncology & carcinogenesisTomographybusinessInstrumentationImage resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct