A. Stepniak

Multirotations-CT und ARDS

Purpose Aim of the study was to investigate alveolar inspiration and expiration using multiscan CT. Results of a visual assessment using a scoring system were compared with density ranges known to represent alveolar ventilation best. Method Pigs were examined before and after lavage-induced ARDS. All animals were examined using dynamic multiscan CT. The visual assessment was done by a scoring system proposed by Gattinoni. The results were compared with planimetric determination of defined density ranges. Results In the healthy lung, the visual analysis showed higher scores at lower airway pressures with a marked gradient, whereas at higher pressures neither opacities nor gradients were obse…

research product

A novel technique to follow fast PaO2 variations during experimental CPR

An ultrafast responding fluorescent-quenching PO2 probe allows time-resolved, in vivo measurement of PO2. This study describes several validation experiments of this new device in vitro, and reports its first use during cardiopulmonary resuscitation in an animal model of cardiac arrest.The influence of CO2, temperature and motion artefacts on the signal response of the PO2 probe was analysed in vitro by systematic variation of these values. Thereafter, with approval of the Review Board for the care and use of animals, CPR was performed in four pigs. The PaO2 course was recorded continuously at time resolution of80 ms in the abdominal aorta using an uncoated fluorescence-quenching probe (Fox…

research product

Functional Evaluation of Emphysema Using Diffusion-Weighted 3Helium-Magnetic Resonance Imaging, High-Resolution Computed Tomography, and Lung Function Tests

Purpose: To assess the emphysematous enlargement of distal air-spaces and concomitant large and small airway disease using diffusion-weighted 3 Helium-magnetic resonance imaging (MRI), high-resolution computed tomography (HRCT), and lung function tests (LFT). Methods: Seven patients were examined after single lung transplantation (LTx) and 1 before double LTx for various forms of emphysema. Five patients after double LTx served as controls. Patients were assessed by 3 Helium-MRI (apparent diffusion coefficient [ADC]), HRCT (mean lung density [MLD], emphysema index [El]), and LFT. Results: Transplanted lungs: mean ADC = 0.17 cm 2 /s, MLD = -848 H, El = 22%. Emphysematous lungs: mean ADC = 0.…

research product

Quantifizierung von Atelektasen bei kontrollierter Beatmung: Spiral-CT versus dynamische Einzelschicht-CT

Ziel: Dynamische CT-Untersuchungen (dCT) erlauben die Darstellung und Quantifizierung ventilierter Lungenflache und Atelektasenbildung wahrend kontinuierlicher Beatmung. Diese Studie ­vergleicht eine quantitative Auswertung einer infrakarinalen dCT-Einzelschicht mit der einer Spiral-CT der gesamten Lunge, um zu untersuchen, ob eine dynamisch gemessene Einzelschicht bezuglich der intrapulmonalen Atelektasenverteilung reprasentativ fur die Gesamtlunge ist. Material und Methoden: An 8 gesunden Schweinen erfolgte eine dCT (Schichtdicke 1 mm, zeitliches Inkrement 100 ms) wahrend kontinuierlicher Beatmung, gefolgt von einer Spiral-CT der gesamten Lunge (Schichtdicke 2 mm; Pitch 1,5; Inkrement 2 m…

research product