0000000000123655

AUTHOR

Helge Simon

Seasonal Changes in Urban PM2.5 Hotspots and Sources from Low-Cost Sensors

PM2.5 concentrations in urban areas are highly variable, both spatially and seasonally. To assess these patterns and the underlying sources, we conducted PM2.5 exposure measurements at the adult breath level (1.6 m) along three ~5 km routes in urban districts of Mainz (Germany) using portable low-cost Alphasense OPC-N3 sensors. The survey took place on five consecutive days including four runs each day (38 in total) in September 2020 and March 2021. While the between-sensor accuracy was tested to be good (R² = 0.98), the recorded PM2.5 values underestimated the official measurement station data by up to 25 µg/m3. The collected data showed no consistent PM2.5 hotspots between September and M…

research product

Modeling impacts of super cool roofs on air temperature at pedestrian level in mesoscale and microscale climate models

Abstract Passive daytime radiative cooling is gaining increasing relevance as recent studies report that newly developed materials with very high reflectivity and emissivity could be able to effectively reduce urban heat stress, when applied as roofing material (super cool roofs). A recent microscale sensitivity study with ENVI-met modeled the impact of super cool roofs with maximum air temperature reductions of around 0.85 K at pedestrian level for an idealized model area. To verify these findings in real urban structures featuring complex building morphologies and varying meteorological conditions, we conducted climate simulations for two contrasting cities: New York City, NY, and Phoenix…

research product

Calibration process and parametrization of tropical plants using ENVI-met V4: São Paulo case study

This work aims to improve the process of calibration of ENVI-met model based on air temperature in both built-up and vegetated areas, considering various parameters and models of trees. Field measu...

research product

Beta-adrenergic stimulation enhances left ventricular diastolic performance in normal subjects.

To determine the effects of beta-adrenergic stimulation on transmitral Doppler echocardiography flow characteristics of left ventricular diastolic filling, we studied 10 healthy volunteers aged 23-31 years (mean age, 26.6 years) during intravenous infusion of isoprenaline in consecutive steps of 0.1, 0.2, 0.4, 0.75, and 1.5 micrograms/min (each for 15 min). Saline control infusion was given in the same manner in a crossover and blinded protocol. Compared with the infusion of placebo, stepwise increasing doses of isoprenaline caused a dose-related increase in early and late diastolic filling velocities and velocity-time integrals, a lengthening of the acceleration time, and a shortening of t…

research product

Modeling transpiration and leaf temperature of urban trees – A case study evaluating the microclimate model ENVI-met against measurement data

Abstract Increasing vegetation cover in cities is a key approach to mitigating urban heat excess. However, both the effect of vegetation on microclimate and the plants’ vitality need to be assessed to support and quantify the effects of such strategies. One way to assess the interactions between vegetation and the urban environment is through microclimate models that can simulate the effects of vegetation onto the urban microclimate as well as effects of urban environments onto vegetation. To provide reliable estimates microclimate models need to be parameterized based on empirically obtained data. In this paper we compare modeled transpiration rates and leaf temperatures of a leading micro…

research product

Modeling the outdoor cooling impact of highly radiative “super cool” materials applied on roofs

Abstract Highly reflective “cool materials” are commonly used to reduce temperatures in the urban environment. Recently developed “super cool” materials feature an even higher albedo and emissivity (both above 0.95) than traditional cool materials. To examine the impacts of super cool roofing materials on outdoor air temperature compared to traditional cool roofs and green roofs, we conduct a sensitivity study with the microclimate model ENVI-met. Simulated surface temperature of super cool roofs remained around 6 K below ambient air temperature during high solar irradiation, which is consistent with observations. Super cool roofs – with an averaged street-level air temperature cooling of a…

research product

Corrigendum to ‘Pathway using WUDAPT's Digital Synthetic City tool towards generating urban canopy parameters for multi-scale urban atmospheric modeling’ [Urban Climate 28 (2019) 100459]

research product

Evaluating the thermal-radiative performance of ENVI-met model for green infrastructure typologies: Experience from a subtropical climate

Abstract Microclimate knowledge has been intensively integrated into urban planning and design to improve the buildings’ energy performance and outdoor thermal comfort. To assess the climatic mitigation strategies, numerical modeling is gaining higher relevance. ENVI-met, a microclimate model to simulate the complex surface-vegetation-atmosphere interactions in the built environment, is receiving increasing popularity. This study aims to systematically evaluate the thermal-radiative performance of the ENVI-met model based on its recent updates. First, a field measurement was conducted in a subtropical city. Thermal-radiative parameters were collected besides three green infrastructure (GI) …

research product

Pathway using WUDAPT's Digital Synthetic City tool towards generating urban canopy parameters for multi-scale urban atmospheric modeling

Abstract The WUDAPT (World Urban Database and Access Portal Tools project goal is to capture consistent information on urban form and function for cities worldwide that can support urban weather, climate, hydrology and air quality modeling. These data are provided as urban canopy parameters (UCPs) as used by weather, climate and air quality models to simulate the effects of urban surfaces on the overlying atmosphere. Information is stored with different levels of detail (LOD). With higher LOD greater spatial precision is provided. At the lowest LOD, Local Climate Zones (LCZ) with nominal UCP ranges is provided (order 100 m or more). To describe the spatial heterogeneity present in cities wi…

research product